34
[Operation by Level signal input activation] (When Direct control function is selected)
• Operation of playback start by Level signal input activation
• Operation when playback is started by Level signal input activation and the closed state is kept even after
program completion
Unit's playback operation
Contact-activated input
OFF
ON
Program
Program
Unit's playback operation
Contact-activated input
OFF
ON
Program
Unit's playback operation
Contact-activated input
OFF
ON
Program
Note
When set to Level signal input activation, playback continues only during the interval if terminals are closed for
a short time.