15
10. RACK MOUNTING
When mounting the unit on an equipment rack, use the optional MB-15B Rack Mounting Bracket.
Before mounting, remove 4 plastic feet on the unit bottom.
Notes
• Be sure to place the unit below heat generating equipment such as power supply units or amplifiers. Put a
perforated panel between the unit and the heat generating equipment as required.
• When installing a digital amplifier in the equipment rack where the unit is installed, keep it at least 2 U* away
from the unit.
Noise may be produced if the digital amplifier is installed in close proximity to the unit.
* 1 U size = 44.5 mm or 1.75" (reference size)
DT-940
Rack mounting screw 5 x 12
(supplied with the MB-15B)
Fiber washer for M5
(supplied with the MB-15B)
Tapping screw 3 x 14
(supplied with the MB-15B)
MB-15B (option)
The rack mounting screws (5 x 12) are
dedicated for the TOA equipment racks.
Do not use them for other racks.
CAUTION