Toa DA-500FH CE Operating Instructions Manual Download Page 4

4

2. GENERAL DESCRIPTION

TOA's DA-550F Multichannel Power Amplifier features high power handling of 550 W x 4 channels (4 

Ω

output) or 350 W x 4 channels (8 

Ω

output) and durability. Besides, its channels 1 and 2, and 3 and 4 are

made available for bridge connection individually, allowing it to be used as a 1,100 W (8 

Ω

) x 2 channels

stereo amplifier or as a 3-channel amplifier comprised of 1,100 W (8 

Ω

) + 550 W (4 

Ω

) x 2 channels.

The DA-500FH Multichannel Power Amplifier features high power handling of 500 W (100 V line) x 4 channels
(20 

Ω

output) and durability.

Their wide range of applications include stores and permanent sound systems. 

3. FEATURES

• 2U rack mounting size*.
• Low power consumption and light weight.
• An input signal to Channel 1 can be routed to all channels, and the output level adjusted using the input level

control for each channel. 

• Electronically-balanced inputs.
• Input terminals employ removable terminal blocks and XLR type connectors to provide maximum connection

ease. 

• Input/output status LED indicators for each channel. 
• Built-in protection circuitry disconnects the output when a short circuit, overload, or unusual temperature rise

occurs. 

• Equipped with the terminals used for internal information monitoring (power supply, protection status, and

fan operation) and power ON/OFF control from external equipment.

* 1U size = 44.5 mm (reference size)

An all-pole mains switch with a contact
separation of at least 3 mm in each pole shall
be incorporated in the electrical installation of
the building. 

The lighting flash with arrowhead symbol,
within an equilateral triangle, is intended
to alert the user to the presence of
uninsulated "dangerous voltage" within
the product's enclosure that may be of
sufficient magnitude to constitute a risk of
electric shock to persons.

• The unit is designed exclusively to be mounted in

an equipment rack. Be sure to follow the
instructions below when rack-mounting the unit.
Failure to do so may cause a fire or personal injury.
· Install the equipment rack on a stable, hard floor. 

Fix it with anchor bolts or take other arrangements
to prevent it from falling down.

· The supplied rack-mounting screws can be used

for the TOA equipment rack only. Do not use
them for other racks.

· When installing the unit in a rack other than that

of TOA, be sure to use the screws with a
diameter of over 5 mm and length of over 12 mm
to mount the unit.

· When connecting the unit's power cord to an AC

outlet, use the AC outlet with current capacity
allowable to the unit.

When the Unit is in Use 

• Make sure that all volume controls are set to

minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing. 

• Do not operate the unit for an extended period of

time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.

• Contact your TOA dealer as to the cleaning. If dust

is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result. 

• If dust accumulates on the power supply plug or in

the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.

• Switch off the power, and unplug the power supply

plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock. 

Summary of Contents for DA-500FH CE

Page 1: ...WER AMPLIFIERS DA 550F CE DA 500FH CE Thank you for purchasing TOA s Multichannel Power Amplifier Please carefully follow the instructions in this manual to ensure long trouble free use of your equipm...

Page 2: ...UT SENSITIVITY SETTING 12 10 PROTECTION OPERATION LIST 12 11 TAMPER PROOF CAP ATTACHMENT 13 12 CLEANING THE FILTER 13 13 DIMENSIONAL DIAGRAM 13 14 BLOCK DIAGRAMS 14 1 DA 550F 14 14 2 DA 500FH 14 15 HO...

Page 3: ...e a fire or electric shock Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit s cover as this may result in fire or electric shock Do not touch a plug...

Page 4: ...er to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The unit is designed exclusivel...

Page 5: ...nser Never use benzene thinner alcohol or chemically treated cleaning cloth because such volatile liquids could deform or discolor the unit 5 INSTALLATION PRECAUTIONS The supplied power supply cord is...

Page 6: ...ights yellow when an output level exceeds about 1 W at an 8 load DA 550F or 20 load DA 500FH Peak indicator PEAK Lights red when an output signal clips distortion occurs Protection indicator PROTECT L...

Page 7: ...10 BRIDGE ON OFF switches DA 550F only BRIDGE 1 BRIDGE 2 ON OFF Used when bridge connecting the unit s Channels 1 and 2 and Channels 3 and 4 See p 8 Settings and Connections 4 channel input mode Set...

Page 8: ...nal cover in place Be sure to replace the unit s terminal cover after connection completion Because high voltage is generated at the speaker output terminals never touch these terminals to avoid elect...

Page 9: ...2 3 inputs 3 outputs 1 CH3 CH4 Speaker output terminals Switch BRIDGE 1 BRIDGE 2 CH 1 mode ON OFF OFF Setting 8 4 8 4 8 CH3 CH4 CH1 CH3 CH4 CH1 CH2 BRIDGE 1 3 inputs 3 outputs 2 BRIDGE 1 BRIDGE 2 Spe...

Page 10: ...CH 1 mode OFF Setting 20 20 20 20 CH1 CH1 CH2 CH2 CH3 CH3 CH4 CH4 4 inputs 4 outputs factory preset CH4 CH3 CH2 CH1 Speaker output terminals Switch CH 1 mode ON Setting 20 20 20 20 CH1 CH1 CH2 CH3 CH...

Page 11: ...sens Terminal screw Slotted screwdriver Shielded cable Removable terminal plug Hot Cold Earth 1 1 2 Bit shape 3 mm 8 REMOVABLE TERMINAL PLUG CONNECTION Cautions Be sure to use shielded cables for audi...

Page 12: ...tact the TOA dealer where the unit was purchased 9 INPUT SENSITIVITY SETTING The input sensitivity for each channel can be set to either 4 dB factory preset or 10 dB These servicing instructions are f...

Page 13: ...filter and ventilation panel Detach the panel by pressing on the right side Filter Ventilation Panel Ventilation Panel 2 3 13 DIMENSIONAL DIAGRAM 465 442 76 2 88 4 482 371 22 5 404 2 Unit mm 11 TAMPER...

Page 14: ...el control ON OFF BRIDGE 2 ON OFF switch BRIDGE 2 OUTPUT Current Limiter Short Detector Protection Circuit OUTPUT 4 relay H C CH 3 INPUT E H C CH 4 INPUT E 14 2 DA 500FH H C CH 1 INPUT E H C CH 2 INPU...

Page 15: ...off in response to the power ON OFF status protection status and fan operation status from the distant location using this terminal This monitor terminal is a photocoupler open collector output termin...

Page 16: ...dicator front panel Light off Light on Protection status output OFF ON 16 Terminal Pin No Pin name Unit operation status HI LEVEL LO LEVEL CH1 2 CH1 power ON OFF control input CH1 power OFF CH1 power...

Page 17: ...for LAN CAT5 STP RJ45 pin No To Control Monitor terminal 1 2 5 6 3 4 7 8 Shield RJ45 pin No Cable color Cable color for T568B for T568A Orange white Green white Orange Green Green white Orange white B...

Page 18: ...re rise over 100 C 100 dB A weighted 70 dB A weighted Control input Power ON OFF status of the individual channels Photocoupler input drive voltage 9 V DC Min 14 V Max 12 V Typ Monitor output Power ON...

Page 19: ...A weighted 70 dB A weighted Control input Power ON OFF status of the individual channels Photocoupler input drive voltage 9 V DC Min 14 V Max 12 V Typ Monitor output Power ON OFF status of the indivi...

Page 20: ...raceability Information for Europe EMC directive 2004 108 EC Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe GmbH Sued...