Toa DA-250D CE Operating Instructions Manual Download Page 3

3

When Installing the Unit

• Do not expose the unit to rain or an environment

where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock. 

• Use the unit only with the voltage specified on the

unit. Using a voltage higher than that which is
specified may result in fire or electric shock.

• Do not cut, kink, otherwise damage nor modify the

power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock. 

• Be sure to replace the unit's terminal cover after

connection completion. Because the voltage of up
to 100 V is applied to the high impedance speaker
terminals, never touch these terminals to avoid
electric shock. (DA-250DH only)

• External wiring connected to the terminals marked

with 

requires installation by an instructed person.

(DA-250DH only)

• The apparatus shall be connected to a mains

socket outlet with a protective earthing connection.

When the Unit is in Use 

• Should the following irregularity be found during

use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest TOA dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock. 

· If you detect smoke or a strange smell coming

from the unit.

· If water or any metallic object gets into the unit 
· If the unit falls, or the unit case breaks 
· If the power supply cord is damaged (exposure of

the core, disconnection, etc.)

· If it is malfunctioning (no tone sounds.)

• To prevent a fire or electric shock, never open nor

remove the unit case as there are high voltage
components inside the unit. Refer all servicing such
as modification inside the unit to qualified service
personnel.

• Do not place cups, bowls, or other containers of

liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock. 

• Do not insert nor drop metallic objects or flammable

materials in the ventilation slots of the unit's cover,
as this may result in fire or electric shock. 

• Do not touch a plug during thunder and lightning,

as this may result in electric shock. 

When Installing the Unit

• Never plug in nor remove the power supply plug

with wet hands, as doing so may cause electric
shock.

• When unplugging the power supply cord, be sure

to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.

1. SAFETY PRECAUTIONS

• Before installation or use, be sure to carefully read all the instructions in this section for correct and safe

operation.

• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or

cautions regarding safety.

• After reading, keep this manual handy for future reference.

Safety Symbol and Message Conventions 

Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards. 

WARNING

Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.

WARNING

CAUTION

CAUTION

Summary of Contents for DA-250D CE

Page 1: ...DA 250D CE DA 250DH CE DA 250D DA 250DH Thank you for purchasing TOA s Dual Power Amplifier Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment O...

Page 2: ...7 1 Switch Settings and Speaker Connections 7 1 1 When using the DA 250D 10 7 1 2 When using the DA 250DH 11 8 REMOVABLE TERMINAL PLUG CONNECTION 12 9 INPUT SENSITIVITY SETTING 13 10 PROTECTION OPERAT...

Page 3: ...unit case as there are high voltage components inside the unit Refer all servicing such as modification inside the unit to qualified service personnel Do not place cups bowls or other containers of l...

Page 4: ...TOA be sure to use the screws with a diameter of over 5 mm and length of over 12 mm to mount the unit When connecting the unit s power cord to an AC outlet use the AC outlet with current capacity all...

Page 5: ...er Their wide range of applications include stores and permanent sound systems 3 FEATURES 1U rack mounting size Low power consumption and light weight An input signal to Channel 1 can be routed to bot...

Page 6: ...y clean the filter located inside the ventilation panel on the unit s front panel If the filter becomes clogged heat will become trapped inside the enclosure Install the unit in locations where the te...

Page 7: ...d 2 above and below every 5 units Robust structure is one of the unit s main features However if the strength is particularly needed when installing the unit in the rack use a supporting runner for th...

Page 8: ...nput signal level exceeds about 20 dB Output indicator OUTPUT Lights yellow when an output level exceeds about 1 W at an 8 load DA 250D or 40 load DA 250DH Peak indicator PEAK Lights red when an outpu...

Page 9: ...ut mode Set BRIDGE switch to ON Note Be sure to first turn off the power switch when changing the BRIDGE switch settings 10 CH 1 mode ON OFF switch PARALLEL ON OFF Setting this switch to ON pressed in...

Page 10: ...put terminals 4 4 Replace the output terminal cover in place Be sure to replace the unit s terminal cover after connection completion Because high voltage is generated at the speaker output terminals...

Page 11: ...F Setting Switch CH 1 mode ON Setting CH1 CH1 CH2 CH2 1 input 2 outputs 2 inputs 2 outputs factory preset 40 40 40 40 Speaker output terminals Switch BRIDGE CH 1 mode ON OFF Setting 8 CH1 CH1 CH2 CH2...

Page 12: ...sens Terminal screw Slotted screwdriver Shielded cable Removable terminal plug Hot Cold Earth 1 1 2 Bit shape 3 mm 8 REMOVABLE TERMINAL PLUG CONNECTION Cautions Be sure to use shielded cables for audi...

Page 13: ...1 and 2 are bridge connected Input sensitivity setting for the CH2 is disabled Step 3 Replace the detached top cover When set to 4 dB When set to 10 dB 10 dB 4 dB 10 dB 4 dB Jumper socket Jumper socke...

Page 14: ...normal operation Short circuit Current limiter activated Load is disconnected Protection indicator lights Check speakers and lines for short circuit Turn off the power switch Correct the load then sw...

Page 15: ...ventilation panel as shown in the figure Step 3 Detach the filter inside the ventilation panel Step 4 Clear the filter of dust Step 5 Replace the filter and ventilation panel Ventilation Panel 2 3 Fi...

Page 16: ...Current Limiter Short Detector Protection Circuit Current Limiter Short Detector Protection Circuit 13 BLOCK DIAGRAMS 13 1 DA 250D 13 2 DA 250DH PARALLEL switch H C CH 1 INPUT E H C CH 2 INPUT E OUTPU...

Page 17: ...17 14 DIMENSIONAL DIAGRAM Unit mm 401 8 371 22 5 482 465 442 31 8 44...

Page 18: ...over 100 C 100 dB A weighted 70 dB A weighted Power blue x 1 Input green x 2 Output yellow x 2 Peak red x 2 Protect red x 2 Forced air cooling 10 C to 40 C Under 90 RH no condensation Panel Aluminum b...

Page 19: ...stance between barriers 8 8 mm 50 20 000 Hz 3 dB 0 dB 0 1 1 kHz 0 3 100 20 000 Hz Protection against excessive current flow due to overload short circuit unusual DC voltage output and heat sink temper...

Page 20: ...raceability Information for Europe EMC directive 2004 108 EC Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe GmbH Sued...

Reviews: