Toa DA-1250D Operating Instructions Manual Download Page 11

 9.

TROUBLESHOOTING

After powered without any response

Measure the outlet with a multimeter to check if 

there is power available and when no multimeter, 

you can have a test pencil. If the power supply is 

normal and the amplifier still no response when 

powered then there is something wrong with the 

amplifier,need prfessional person to check it. 

No signal output
1. Frist check if the signal input is right.

Check the connect of XLR, if the 2 and 3 

    reverted or the ground is reliable. Different 

    circuitry design will have different connect way 

    of the XLR, please follow the 2+

3- to soldering.

It can not be judged by comparing with other 

    amplifiers (including other amplifiers in the 
    same factory).
2. The signal light don't lights up

 If all the signal input is fine and the signal light 

    don't lights up then may the amplifier has failure, 

    you need to ask the professional person to 

    check it.
3. Signal input normal but no sound

The signal light will flash with the change of input 

    volume, but no sound out, then you can check 

    the connect of speakon if it is connect good and 

    the wires are connect right (some times the 

    problem of the wires connect, check its±

1 and

 ±2 

    connect), after the check above if still no sound 

    out, please change a speaker cable and check 

    again. Because some times also caused by the 

    bad quality of the Speakon connector problem of 

    the amplifier

          Through experiences, it may caused by the 

    bad connection of some plugs and the socket.    

Output sound distortion

1.  After check the signal and loudspeaker 

        they are fine and still can hear distortion when 

        small sound, then may the amplifier has 

        failure, need professional person to check it.

    2. Some frequency band has distortion

        First, check if the loudspeaker already 

        overload, normally judge it in 95~105dB for 

        higher SPL we don't comment here. Here we 

        just think about the failure recovery of the 

        amplifier. If in the middle have some rupture 

        sound and more smaller volume more 

        obvious, then it should be crossover distortion

        of the amplifier and this kind of distortion is 

        easy to confuse with the failure of loudspeaker 

        itself. If the amplifier have for problem then you 

        should send back to the manufactur for repair.

3.  Distortion is High SPL

        If the sound is normal when small volume and 

        then you need to check the limit SPL of the 

        loudspeaker. You can listn it in suitable volume 

        and if clip light works, then you need reduce

the output. Both loudspeaker and amplifier 

        have limit, you should use them in their limit if 

The protection light blinks
When the PROTECT light works, the amplifier
into the protection mode. 

 1.  Maybe the temperature is too high or output 

        short or near short and they are not failure they    

        can recovery after you can use it normally. But

        over heat will take more time to recovery. Also

        when over heat happened you should cheak

        the fan and the temperature of the install 

        environment, if does you should solve the 

        problem then can use amplifier. If you think the

speaker was short, you can with a multimeter 

        to check if the resist is lower than 2 ohm or 1 

        ohm with DC (Please calibrate the multimeter 

        to measure for accuracy because of the small 

        esistance).

    2. If the PROTECT awlays light up then it should 

        be the problem of amplifier, you should send  

        it back to professional person for repair. 

Hum in the system

1. Hum exists even when there is no signal 

        Please keep the amplifier away from earth 

        wire of power supply cables, just connect the 

        fire wire and zero wire, no ground wire. If the 

        hum is still existing, it can be judged that there 

        are some problems in the amplifier. Please 

        get in touch with professionals. 

    2. Hum exists when the system is completely 

        connected This is caused by the different 

        ground voltages in difference devices in the 

        system, mainly happens when the power 

        supply is under three-phase distribution 

        condition, each device is connected to 

        different phase. This is not caused by amplifier.

The amplifier is required maintenance in the
condition below: 

    1. If the amplifier smokes or smells burning.

    2. If the cabinet has severe indentation and 

        deformation.

    3.  If the amplifier are dipped into the water.

   4. If the internal components loosen.

    5. If AC breaker skips out when current increases.  

in very high SPL they have distortion you should 

take care of them and reduce the output to the 

right position.   

Solution experiences, just for reference

A. Combing the electricity the power distribution 

         box using the same one for all if possible.

B. Make sure the grounding wire potential is zero 

         and force the different grounding wire to the 

         same level, if the grounding wire itself charged,  

         indicates that the wire may be connected with 

         the zero line. Please solve this problem.

    c.  If unavailable above, then only to disconnect 

         the ground wires of all devices, which helps to 

         reduce the AC. But this is not meet the safe 

         use of electricity, user s must know what will 

         happen if to do in this way. We do not 

         recommend the floating use.  

11

Summary of Contents for DA-1250D

Page 1: ...IONS 7 6 SYSTEM CONNECTION CASES 8 7 THERMAL DISSIPATION 9 8 POWER LEVEL ADJUSTMENT 10 9 TROUBLESHOOTING 11 10 SPECIFICATIONS 12 11 DIMENSIONAL DIAGRAM 12 12 ARABIC IMPORTANT SAFETY INSTRUCTIONS 13 TA...

Page 2: ...periods of time Refer all servicing to qualified service personnel Servicing is damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the...

Page 3: ...unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object gets into the unit If the unit falls or the...

Page 4: ...switched on can impair hearing Do not operate the unit for an extended period of time with the sound distorting This is an indication of a malfunction which in turn can cause heat to generate and resu...

Page 5: ...olumes CH2 knob lose efficacy 3 LED indicator PROTECT Lights red when either protection circuit action CLIP Lights red when compressor limiter is protecting the amplifier from input overload 5dB Light...

Page 6: ...to speakers Refer to p 7 and p 8 9 Signal input 20k balanced 10k unbalanced XLR F connector Connects to Signal source 6 10 Sensitivity selector switch Selects the input Refer to p 8 11 Mode selector s...

Page 7: ...failure NOTES T It can work good from 8 to 16 in bridge mode he speaker connector can work from 4 16 in srereo or parallel model Inputs Outputs BLACK RED 20mm 8mm 0 8 0 3 7 Speakon NL4 Negative black...

Page 8: ...ridge mode Parallel mode Stereo mode CH 1 CH 2 CH 1 CH 2 INPUT MODE OUTPUT CH 1 CH 2 CH 1 CH 2 INPUT MODE OUTPUT CH 1 CH 2 SPEAKER 1 SPEAKER 1 SPEAKER 2 CH 1 CH 2 1 2 INPUT MODE OUTPUT BRIDGE PARALLEL...

Page 9: ...r The first time cleaning of strainer mesh should be right after installation Recommend to clean the strainer mesh quarerly Pease do not run the product without the dust filter or it makes the service...

Page 10: ...should operated by professional person if you don t know how to do please be careful Mixer Processor Input the stable pink noise Put the line output to 0dB LEVEL 40 20 12 6 3 0 3 6 12 CLIP CH 0 12 MAI...

Page 11: ...works then you need reduce the output Both loudspeaker and amplifier have limit you should use them in their limit if The protection light blinks When the PROTECT light works the amplifier into the p...

Page 12: ...1 2 XLR M connector SPEAKER 1 2 2 channels 700Wx2 8 1250Wx2 4 1 channels BRIDGE 2500Wx1 8 NL4 SPEAKON connector Frequency Response 20Hz 20kHz 3dB Total Harmonic Distortion 0 15 S N Rate 100dB LED Indi...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ......

Reviews: