background image

5 DIP 

SWITCH 

FOR 

FUNCTION SELECTION ON CCU-11B

The DIP switches on the CCU-11B allow selection of the following functions;

Switches

Functions

DIP-SW "ON "Position

DIP-SW "OFF "Position

Mini-Jumper for  Battery

Battery "ON"

Position

Battery "OFF"

Position

OFF

OFF

Remote Control  (Door)

Continues Calling Tone

OFF

OFF

Priority & Executive Priority

Press to Talk Control

Time  Interval  Adjustment
before All  Call  Paging Pre-
announce Tone

Calling Tone Duration

Call Transfer

All Call Paging & Response

Make/Break Relay Output

Activate

Activate

Activate

1 ~ 2 sec.

Short (0.7 sec)

Activate

Activate

One shot Relay Output

(4 sec.)

Not Activate

Not Activate

Not Activate

None

Long (1.3 sec)

Not Activate

Not Activate

Programming Switch

Station No. 11  is
"Programming station'

Station No. 11  is a
normal station

PROG

sw

SW-B (SW1)

SW-A (SW2)

1: BATT. OFF

2: BATT. ON

OFF

ON

A. All 

Call 

Paging 

and 

Response

B. Call Holding/Call Transfer

C. Calling 

Tone 

Duration

D.  Time Interval Adjustment before All Call Paging

E. PTT 

Control

F. Priority 

and 

Executive 

Priority

G. Remote 

Control

H. Continuous Calling Tone

— 5 —

Summary of Contents for CCU-11B

Page 1: ...INTERCOM SYSTEM Central Control Unit TOA ELECTRIC CO LTD KOBE JAPAN TOA EXES 1000 INTERCOM SYSTEM CCU 11B INSTALLATION HAND BOOK 133 21 012 7A...

Page 2: ...ons for Installation of CCU 11B 3 5 DIP Switch for Function Selection on CCU 11 B 5 6 Station No 11 Programming for Each Function 5 7 Remote Control Relay RY1 RY2 on CCU 11B 8 7 1 Functions and Operat...

Page 3: ...tive equipment There are certain minimum installation requirements to be met even though you may not need many additional functions or additional equipment it is still necessary to read 4 Initial CCU...

Page 4: ...d registration at station No 11 when you install the new unit Otherwise some other functions may not work properly 7 The Ni Cd battery GB50 3FA1 is capable of saving im portant memory registration dat...

Page 5: ...change Turn on PROGRAM switch on the CCU card No First installation Yes Initial set Is all programming data required to be cleared No Yes Dial operation from station 11 Confirmation tone Touch ten tim...

Page 6: ...g Tone Duration CallTransfer All Call Paging Response Make Break Relay Output Activate Activate Activate 1 2 sec Short 0 7 sec Activate Activate One shot Relay Output 4sec Not Activate Not Activate No...

Page 7: ...ct dialing privacy tone will be sound Re start from the beginning 2 When All Call Paging is used the registration to the station 10 can not be done The following shows how to register the functions 1...

Page 8: ...ship New registration Sub station Number Master station Number Ascertain holding tone All registration finished Release Sub station Number Sub station Number Ascertain holding tone Release finished Re...

Page 9: ...ial gives break contact for door closing SW B 2 OFF RY2 C Power ON OFF Remote Control When the system is used in conjunction with PA amplifier for the external All Call paging the power switch of the...

Page 10: ...B B RM1 terminals on TBM 11 are for the door remote control relay contacts and RM2 terminals on TBM 11 are for the power ON OFF remote control or press to talk remote control relay contacts Please ref...

Page 11: ...of those functions assigned to each station Function Table for Stations Functions Name 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Continuous Callin...

Page 12: ...TOAELECTRIC CO LTD KOBE JAPAN Printed in Japan...