![Toa C-RM500 Operating Instructions Manual Download Page 45](http://html1.mh-extra.com/html/toa/c-rm500/c-rm500_operating-instructions-manual_1122988045.webp)
45
Camera input/output
Monitor output
Alarm I/O
RS-232C
IN
IN
2
1
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Multi-switcher
Monitor TV
Fixed camera
*
*
C-RM500
Sensor
1
4
6
9
5, 10
Sensor
1
4
6
9
5, 10
A
B
A
B
Combination camera
Combination camera
1
2
3
4
5
1
2
3
4
5
Camera control
cable
Alarm input
cable
Camera control
cable
Alarm input
cable
Shielded twisted-pair cable
GND
Camera control terminal
Alarm output terminal
Switcher control terminal
RS-232C
Sensor
A
B
RS-232C reverse cable
Female D-sub 9-pin connector to Female D-sub 9-pin connector
The use of each camera's alarm input permits
connection of 8 sensors for each camera.
Corresponding to
the fixed camera A
Corresponding to
the fixed camera B
* Connect this cable only when "2. LEVEL" is selected in the unit's "Alarm signal" setting. (Refer to p. 35.)
Connect the C-RM500's alarm output corresponding to the Combination Camera address to the Multi-
Switcher's alarm input, while leaving other output terminals not corresponding to any Camera address
unconnected.
Summary of Contents for C-RM500