Toa C-IF500 Instruction Manual Download Page 1

INSTRUCTION MANUAL

INTERFACE UNIT

C-IF500

1. SAFETY PRECAUTIONS  .......................... 2

2. GENERAL DESCRIPTION  ........................ 3

3. FEATURES  ................................................ 3

4. NOMENCLATURE AND FUNCTIONS

Front ........................................................... 4
Rear ............................................................ 4

5. CONNECTIONS 

5.1. System Examples ................................. 5
5.2. Connecting 32 or 

More Combination Cameras ................ 6

5.3. Star Connection .................................... 7

6. SPECIFICATIONS  ...................................... 8

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.

TABLE OF CONTENTS

Summary of Contents for C-IF500

Page 1: ...TIONS Front 4 Rear 4 5 CONNECTIONS 5 1 System Examples 5 5 2 Connecting 32 or More Combination Cameras 6 5 3 Star Connection 7 6 SPECIFICATIONS 8 Please follow the instructions in this manual to obtai...

Page 2: ...the unit If they accidentally spill into the unit this may cause a fire or electric shock Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit s cover a...

Page 3: ...lt in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition...

Page 4: ...used in the OFF position depending on the connection method Refer to p 6 for details 10 RS 232C terminal SLAVE RS 232C Converts the data received at the Master Connection Terminal into the RS 232C si...

Page 5: ...oller C IF500 5 5 CONNECTIONS 5 1 System Examples Example 1 Combination camera Monitor TV Multi switcher Remote controller C IF500 Example 2 Bottom TOA Corporation model C IF500 120 MADE IN JAPAN 12V...

Page 6: ...iameter If multiple cameras are connected to a single terminal the total of each cable distance between connected equipment must be 1 2 km or less Termination switch setting Set the unit s termination...

Page 7: ...ination switch ON Ch 2 Termination switch ON Ch 3 Termination switch ON Ch 4 Termination switch ON Ch 5 Termination switch ON Ch 6 Termination switch ON Ch 7 Termination switch ON Ch 8 Termination swi...

Page 8: ...PEV S cable thicker than 0 65 mm in diameter is used Optional Equipment MB 15B BK Rack mounting bracket for rack mounting one C IF500 unit MB 15B J Rack mounting bracket for rack mounting two C IF500...