24
11. Attach the supplied safety wire to the base unit.
Camera
direction
Footing
M4 x 8 machine screw
(supplied with the combination camera)
12. Attach removed footings to the base unit.
• First fix two of the base unit mounting holes as shown below.
• Use the screws supplied with the combination camera.
Use screws M3 x 8
tightened to the base unit.
Camera direction
Secure these two holes first.
(Base unit mounting holes)
10. Attach two saddle brackets to the suspension pipe.
• Align the screw installed in the saddle bracket with the hole in the pipe.
• Attach the saddle bracket so that the orientation of its oval holes is as shown in the figure.
Note:
Ensure that the saddle brackets are securely fixed without any play.
Suspension pipe
mounted to the ceiling.
Saddle bracket
Oval hole
Screw
Summary of Contents for C-CC514 NT
Page 43: ...43...