Toa BG-220 Operating Instructions Manual Download Page 3

3

When Installing the Unit

• Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as

doing so may result in fire or electric shock. 

• Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified

may result in fire or electric shock.

• Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power

cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power
cord, as doing so may result in fire or electric shock. 

• Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface.

Doing so may result in the unit falling down and causing personal injury and/or property damage. 

• External wiring connected to the terminals marked with

requires installation by an instructed person.

• The apparatus shall be connected to a mains socket outlet with a protective earthing connection.

• The socket-outlet shall be installed near the equipment and the plug (disconnecting device) shall be easily

accessible.

• Use the optional Rack mounting bracket MB-25B-BK or MB-25B-J when mounting the unit(s) in an

equipment rack. Remove four M4 x 8 screws on both sides of the unit, and mount the bracket there using
the M4 x 16 screws (supplied with the bracket) instead.

When the Unit is in Use 

• Should the following irregularity be found during use, immediately switch off the power, disconnect the power

supply plug from the AC outlet and contact your nearest TOA dealer. Make no further attempt to operate the
unit in this condition as this may cause fire or electric shock. 
· If you detect smoke or a strange smell coming from the unit
· If water or any metallic object gets into the unit 
· If the unit falls, or the unit case breaks 
· If the power supply cord is damaged (exposure of the core, disconnection, etc.)
· If it is malfunctioning (no tone sounds.)

• To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage

components inside the unit. Refer all servicing to your nearest TOA dealer.

• Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they

accidentally spill into the unit, this may cause a fire or electric shock. 

• Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as

this may result in fire or electric shock. 

2. SAFETY PRECAUTIONS

• Before installation or use, be sure to carefully read all the instructions in this section for correct and safe

operation.

• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or

cautions regarding safety.

• After reading, keep this manual handy for future reference.

Safety Symbol and Message Conventions 

Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards. 

Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury. 

WARNING

The exclamation point within an equilateral triangle is intended to alert the user to the presence of
important operation and maintenance (servicing) instruction in the literature accompanying the
appliance.

Summary of Contents for BG-220

Page 1: ...tomatic Mute 10 8 MOH OUTPUT ASSIGNMENT 11 9 2 CHANNEL BROADCAST 11 10 OPERATION 12 11 INSTALLATION PRECAUTIONS 12 12 RACK MOUNTING BRACKET ATTACHMENT 12 13 VOLUME SETTING 13 14 VOLUME CONTROL COVER 1...

Page 2: ...to your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where th...

Page 3: ...is may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object gets into the unit If the unit falls or the unit case breaks If the powe...

Page 4: ...e rack Keep the amplifier over 10 cm 3 94 away from objects that may obstruct air flow to prevent the unit s internal temperature rise When the Unit is in Use Do not place heavy objects on the unit as...

Page 5: ...3 input mixer amplifiers for background music and general announcement Power output is rated at 20 W for the BG 220 and 35 W for the BG 235 These units are suited for use in bars retail stores and ban...

Page 6: ...11 Note Bass and treble controls are not active for this output 12 MOH volume control Adjusts the MOH output signal level 11 4 Line 2 input volume control Adjusts gain of the Line 2 input Turn the kn...

Page 7: ...ecommended to cut the audio signal at the input equipment such as a microphone with talk switch 15 Manual mute terminal Closing between and terminals mutes the input signal set for Mute Receive by the...

Page 8: ...12 24 Cable end treatment 7 mm 7 mm 20 mm 2 core shielded cable Solid cable and stranded cable Wiring Procedure Step 1 Wiring the supplied removable terminal plug 1 1 Loosen the terminal screws to ins...

Page 9: ...in the figures below represent total speaker load impedance 70 V LINE Total impedance 245 BG 220 140 BG 235 25 V LINE Total impedance 31 BG 220 18 BG 235 Speaker output terminal COM 4 Speaker output t...

Page 10: ...0 0 10 OFF ON 0 E Manual mute terminal Mute sensitivity control Function switch Nos 5 6 and 7 MOH ASSIGN 1 MIC LINE 1 2 LINE 2 3 LINE 3 7 AUTO MUTE MIC LINE 1 8 MIC ON LINE OFF 4 5 LINE 2 6 LINE 3 MUT...

Page 11: ...ch No 1 MIC LINE 1 input Function switch No 2 LINE 2 input Function switch No 3 LINE 3 input 9 2 CHANNEL BROADCAST Input signals set in Section 8 are output to the MOH output 2 channel broadcast can b...

Page 12: ...the screws that are appropriate for the rack When mounting the unit in an equipment rack the inside of the rack must be sufficiently ventilated To achieve sufficient ventilation also mount the option...

Page 13: ...e control so that the signal indicator lights intermittently Note that the sound quality is downgraded when the peak indicator remains lit Mounting bracket Joint bracket Machine screw M4 x 10 Amplifie...

Page 14: ...AMP MIX AMP 25 V LINE 4 COM H C E OT MOH OUT ZONE 2 600 1 MOH ASSIGN MIC LINE 1 2 MOH ASSIGN LINE 2 3 MOH ASSIGN LINE 3 4 5 MUTE RECIEVE LINE 2 6 MUTE RECIEVE LINE 3 7 AUTO MUTE MIC LINE 1 8 MIC ON LI...

Page 15: ...15 16 DIMENSIONAL DIAGRAM Unit mm in 1800 70 87 210 8 27 6 M4 265 10 43 249 9 8 40 1 57 165 6 5 15 0 59 58 4 2 3 94 3 3 71 88 4 3 48...

Page 16: ...Output Regulation 1 kHz Under 2 dB no load to full load S N Ratio Microphone Line 1 Over 60 dB Line 2 Over 80 dB Line 3 Over 80 dB Band Pass 20 Hz 20 kHz Tone Controls Centered Tone Control Bass 10 d...

Reviews: