7. OPERATION

 

 

After completing all audio and control connections, connect the power supply, and check the power indicator. 

 

Note:

 

 

When the heat sink temperature exceeds 130°C (266 °F), the protection circuit begins to operate to disconnect 
the output from the circuit. The disconnected output is automatically restored as soon as the temperature 
returns to the normal operating range.

 

 

 

8. INSTALLATION PRECAUTIONS 

 
 

CAUTION

 

 

Keep the amplifier over 10 cm (3.94") away from 
objects that may obstruct air flow to prevent the 
unit's internal temperature rise.

 

 

 

 

 

 

 

 

 

 

 

 

 

9. ADJUSTMENT

 

 

9.1. Input Sensitivity Selection 

Output level is  adjustable  with  individual  -10dBV/-20dBV switch. For those audio source equipments which 
always have relative high output level, such as CD players, please set the input sensitivity selection switch to  
-10dBV position; otherwise, set to -20dBV position. 
 

9.2. Output Volume Setting

 

Output level is  adjustable with master volume control.  For music play or announcement, adjust the proper 
volume control or sensitivity so that the signal indicator lights intermittently. Note that the sound quality is 
downgraded when the peak indicator remains lit.

 

 

When a Remove Volume Control is connected, attenuating the value of the potentiometer will reduce the 
volume level. This attenuation works for the audio signal after adjusted by its master volume control. 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 11 

Summary of Contents for AV-60S-AM

Page 1: ...IONS P6 9 2 Output Volume Setting P11 Front P6 10 BLOCK DIAGRAM P12 Rear P7 11 DIMENTIONAL DIAGRAM P13 6 CONNECTIONS P9 12 SPECIFICATIONS P14 6 1 Removable Terminal Plug Connection P9 13 APPENDIX P15...

Page 2: ...t an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the appa...

Page 3: ...ournie ne rentre pas dans votre prise consultez un lectricien pour faire remplacer la prise obsol te Emp chez le cordon d alimentation d tre pi tin ou pinc particuli rement au niveau des prises lectri...

Page 4: ...jects including the unit itself on the power cord as doing so may result in fire or electric shock Avoid installing or mounting the unit in unstable locations such as on a rickety table or a slanted s...

Page 5: ...rack mounting screws are supplied with the unit Separately prepare the appropriate screws for the rack Keep the amplifier over 10 cm 3 94 away from objects that may obstruct air flow to prevent the un...

Page 6: ...ut terminal blocks facilitate installation and maintenance Built in ALC Auto Level Compressor circuit to protect the connected speakers and internal components from the over loaded input Working in AC...

Page 7: ...ing the cause of the breaker trip press the button to reset the breaker 9 AC receptacle Connect AC cord from this inlet to AC wall outlet P S This IEC power receptacle can be removed and replaced with...

Page 8: ...Connect a sound source equipment such as a CD player 15 Remote volume control 10K Ohms removable terminal block 2P Use it as a remote volume control 16 Output selector switch Move the switch downwards...

Page 9: ...erminal screws to insert the wire 1 2 Tighten the terminal screws Ensure that the wire does not break free when pulled If the wire does pull free repeat the connection procedure from the start Step 2...

Page 10: ...tentiometer will reduce the audio level This attenuation works for the audio signal after adjusted by its master volume control 6 5 AC Power Connections If necessary this power receptacle can be repla...

Page 11: ...ity Selection Output level is adjustable with individual 10dBV 20dBV switch For those audio source equipments which always have relative high output level such as CD players please set the input sensi...

Page 12: ...10 BLOCK DIAGRAM 12...

Page 13: ...11 DIMENSIONAL DIAGRAM 13...

Page 14: ...istortion THD N Less than 0 15 Input Line 1 10 20dB selectable 10K Ohms transformer balanced removable terminal block Line 2 10 20dB selectable 10K Ohms unbalanced 3 5mm stereo jack Line 3 10 20dB sel...

Page 15: ...3 2 Installation With Flexible Conduit Cable Install the flexible conduit cable assembly to AV 60S AM as following procedures 1 Remove the IEC power cord 2 Remove and retain the two Philips head screw...

Page 16: ...Receptacle Fig 2 Fig 1 16 Remove side screws Terminal block Ground wire nut Terminal block Ground wire nut EMT adaptor plate Conduit nut Hot terminal Hot terminal Neutral terminal Neutral terminal TO...

Reviews: