13. APPENDIX – Installation Guide for Flexible Conduit Adapter Kit  

 

13.1. Cautions and Warnings

 . 

 

CAUTIONS 

* Make sure that the AV-20D or the source devices, and all output devices are turned off and disconnected from  

the power source before you begin. 

* A UL listed electrical distribution box is recommended for the termination of the conduit. 

* The UL approved electrical distribution box and flexible conduit are not included; the installer is responsible for 

obtaining and installing them.

        

WARNINGS 

* The circuit breaker used for this connection should be rated a minimum of 20 Amps.          
* Installation and service must be performed by a qualified electrician only.         
* This unit must be installed in accordance with the National Electrical Code and with all local codes.   
* An all poles mains switch with a contact separation of at least 3mm in each pole must be incorporated  in the 

electrical  installation  of  the  building.  The  installation  must  be  carried  out  in  accordance  with  all  applicable 
installation rules.  

* This unit is not to be used beyond its rated voltage range.          
* This unit must be wired to a UL listed distribution box. 
* If it is used for a branch-circuit wiring or anticipated at a TERMINAL connection,  a minimum 14AWG (2.1mm

2

 ) 

conductor (2.1mm) should be used. The conductor material should be copper or aluminum.  

*A pigtail lead should not be more than two wire sizes smaller than the mains supply conductor to which it will be 

connected. 

 .

 

13.2. Installation With Flexible Conduit Cable

 

Install the flexible conduit cable assembly to AV-20D as following procedures: 

1. Remove the IEC power cord. 

2. Remove and retain the two Philips head screws that secure the AC receptacle to the back panel (Fig.1). 

3. Remove and retain the

 

10 screws

 

that secured the top cover of AV-20D to its main chassis (Fig.2). 

4. Carefully lift the top cover up, remove and retain it.  

5.  Use  a  standard  screwdriver  to  loosen  the  screws  holding  the  Hot  and  Neutral  wires  on  the  terminal  block 

(Fig.3). 

6. Unscrew the AC receptacle ground wire from the ground screw nut on the metal bottom of AV-20D.  

7. From the back panel end, pull the AC receptacle out of the enclosure. 

8  Thread the 12- or 14-gauge power wires though the length of the electrical conduit tube. 

9. Install the EMT adapter plate with the conduit attached (Fig.4) into the opening from which you removed the 

AC receptacle. Use the Philips head screws that you removed in step 2 to attach the EMT adapter plate. 

10. Slide the conduit nut (Fig.4) over the bundle of the wires exiting the conduit and onto the conduit itself. Hand 

tighten the nut. 

11. Attach and screw down the Hot and Neutral wires exiting from the conduit to their corresponding screws on 

the terminal block. Be sure that the polarity of the AC wires is correct. 

12. Secure firmly the ground wire from the conduit to the metal bottom by reattaching the ground wire nut.  

13. Screw the cable tie mount on the corner of the PCB.  

14.  Thread  a  tie  wrap  though  the cable  tie  mount,  place  all  wires  within  its  cradle,  and zip  the  wrap  over  the 

bundle of wires. 

15. Ensure that the conduit nut from step 10 (Fig.4) firmly secures the conduit EMT adapter plate. 

16. Use the

 

10 screws you removed in step 3 to secure the top cover of the AV-20D back onto its main chassis.  

 

 

 

 

  

14 

Summary of Contents for AV-20D

Page 1: ...RE AND FUNCTIONS P5 9 2 Output Volume Setting P10 Front P5 10 BLOCK DIAGRAM P11 Rear P6 11 DIMENTIONAL DIAGRAM P12 6 CONNECTIONS P8 12 SPECIFICATIONS P13 6 1 Removable Terminal Plug Connection P8 13 APPENDIX P14 6 2 Input Connections P8 6 3 Speaker Connections P9 6 4 Remote Volume Connection P9 6 5 AC Power Connections P9 Thank you for purchasing TOA s Power Amplifier Please carefully follow the i...

Page 2: ...lt an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used ...

Page 3: ... close proximity to heaters and never place heavy objects including the unit itself on the power cord as doing so may result in fire or electric shock Avoid installing or mounting the unit in unstable locations such as on a rickety table or a slanted surface Doing so may result in the unit falling down and causing personal injury and or property damage The apparatus shall be connected to a mains s...

Page 4: ...ck mounting screws are supplied with the unit Separately prepare the appropriate screws for the rack Keep the amplifier over 10 cm 3 94 away from objects that may obstruct air flow to prevent the unit s internal temperature rise When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition...

Page 5: ...ental operation Removable input output terminal blocks facilitate installation and maintenance Built in ALC Auto Level Compressor circuit to protect the connected speakers and internal components from the over loaded input Working in AC100V 240V 50Hz 60Hz UL2043 plenum rated construction for in the ceiling installation using attached EMT adaptor plate 5 NOMENCLATURE AND FUNCTIONS Front This figure...

Page 6: ...ed button in the breaker pops out to indicate that the breaker has tripped After turning off the power and eliminating the cause of the breaker trip press the button to reset the breaker 9 AC receptacle Connect AC cord from this inlet to AC wall outlet P S This IEC power receptacle can be removed and replaced with Flexible Conduit Adapter using EMT adaptor plate attached to the unit For UL2043 cer...

Page 7: ...als 10K Ohms unbalanced RCA jack Connect a sound source equipment such as a CD player 15 Remote volume control 10K Ohms removable terminal block 2P Use it as a remote volume control 16 Mono Stereo switch Move the switch downwards to set the channels in stereo mode move upwards to set the channels in mono mode 17 Bridge ON OFF switch Move the switch downwards to set the amplifier in two channels ou...

Page 8: ...rt the wire 1 2 Tighten the terminal screws Ensure that the wire does not break free when pulled If the wire does pull free repeat the connection procedure from the start Step 2 Insert the wired terminal plug into the corresponding terminal block in the unit s rear panel Step 3 Tighten the fixing screws Speaker output terminals only Notes Do not reverse Steps 1 and 2 Poor contact may result if for...

Page 9: ...elow Attenuating the value of the potentiometer will reduce the audio level This attenuation works for the audio signal after adjusted by its master volume control 6 5 AC Power Connections If necessary this power receptacle can be replaced with flexible conduit adapter For UL2043 certification the optional receptacle which can be directly connected AC wires with the screw terminals on the PCB is r...

Page 10: ...adjust the proper volume control or sensitivity so that the signal indicator lights intermittently Note that the sound quality is downgraded when the peak indicator remains lit For those audio source equipments which always have relative high output level such as CD players please set the input sensitivity selection switch to 10dBV position otherwise set to 20dBV position 9 2 Output Volume Setting...

Page 11: ...10 BLOCK DIAGRAM 11 ...

Page 12: ...11 DIMENSIONAL DIAGRAM 12 ...

Page 13: ...D N Less than 0 15 Line 1 10 20dB selectable 10 K Ohms transformer balanced removable terminal block Line 2 10 20dB selectable 10 K Ohms unbalanced 3 5mm stereo jack Input Line 3 10 20dB selectable 10 K Ohms unbalanced RCA jacks Output Speaker Output Removable terminal block 4P Tone Control Bass 10 dB at 100 Hz Treble 10 dB at 10 kHz Controls Master volume control Remote volume control Bass tone c...

Page 14: ...embly to AV 20D as following procedures 1 Remove the IEC power cord 2 Remove and retain the two Philips head screws that secure the AC receptacle to the back panel Fig 1 3 Remove and retain the 10 screws that secured the top cover of AV 20D to its main chassis Fig 2 4 Carefully lift the top cover up remove and retain it 5 Use a standard screwdriver to loosen the screws holding the Hot and Neutral ...

Page 15: ...15 ...

Page 16: ......

Reviews: