2. CONNECTIONS

1. WIRING DIAGRAMS

Please follow the instructions manual to obtain the optimum results from this unit. 
We also recommend that you keep this manual handy for future reference. 

2-wire connection

3-wire connection

4-wire connection

4. SPECIFICATIONS

Model

Attenuations

Input Capacity

Override Indicator 
Overriding Voltage
Dimensions 
Weight 
Color

Finish

AT-4012 AS

AT-4030 AS

AT-4060 AS

12 Watt

30 Watt

60 Watt

8 Steps ( 0 dB, -3dB, -6dB, -9dB, -12dB, -15dB, -18dB, OFF )

Red LED  (4-wire connection only)

24V, 11mA DC  (4-wire connection only)

86 (W) x 86 (H) x 24 (D) mm

86 (W) x 86 (H) x 51 (D) mm

White (RAL 9016 or equivalent)

Knob, Cover Panel : ABS Resin, White (RAL 9016 or equivalent)

Note:

 Back Box is not available for AT-4012 AS.
 The design and specifications are subject to change without notice for improvement.

 Accessories

   Back Box 85.5 (W) x 85.5 (H) x 60 (D) mm ............... 1
   Plate mounting screw ............................................... 2

This product can be installed by Surface Mounting or Flush Mounting. We recommend following 
step by step to install this product. For better installation, please consult a contractor, dealer, or 
professional installer.

3.1. SURFACE MOUNTING

3. INSTALLATIONS

55

55

 4 holes 

WALL

URL : http://www.toa.com.sg/

Applicable cable :
Range : 22 - 14 AWG
Solid copper wire  :     0.6mm -    1.6mm
Stranded copper wire  :     0.8mm -    2mm

Unit : mm

Strip the shield of the cable approx. 9mm.

After  loosening  the  screws  at  terminal 
block,  insert  the  core  of  the  cables  fully 
into the specified terminal block. Tighten 
the screws and make sure the cables are 
not loose.

To  prepare  for  installation,  mark  the  4 
holes  on  the  wall  with  the  back  box  as 
shown  in  the  picture.  For  AT-4012  AS 
which  uses  the  common  electrical  box, 
check the dimension specifications of the 
common  electrical  box  for  proper     
installation.

Hot In COM

 approx. 9 mm 

 Cable 

 

Core

 

N.C N.C

Hot In COM

Note : N.C is NOT CONECTED

Terminal
Usable Cable

Cable range 22 - 14 AWG

Screw type x 5 ( Terminal )

Front Panel (Plate) : Surface treated steel plate

0.12 Kg

0.45 Kg

0.46 Kg

Model

Attenuations

Input Capacity

Override Indicator 
Overriding Voltage
Dimensions 
Weight 
Color

Finish

AT-4120 AS

AT-4200 AS

120 Watt

200 Watt

8 Steps ( 0 dB, -3dB, -6dB, -9dB, -12dB, -15dB, -18dB, OFF )

Red LED  (4-wire connection only)

24V, 11mA DC  (4-wire connection only)

86 (W) x 86 (H) x 51 (D) mm

White (RAL 9016 or equivalent)

Knob, Cover Panel : ABS Resin, White (RAL 9016 or equivalent)

Terminal
Usable Cable

Cable range 22 - 14 AWG

Screw type x 5 ( Terminal )

Front Panel (Plate) : Surface treated steel plate

0.48 Kg

0.49 Kg

AT-4000 SERIES

ATTENUATOR

INSTALLATION MANUAL

Traceability Information for Europe

Manufacturer:

TOA Corporation

7-2-1,

 

Minatojima-Nakamachi,

 

Chuo-ku,

 

Kobe, Hyogo,

 

Japan

Authorized representative:

TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg,
Germany