TOA NEW 900 SERIES

Plug-in Modules

Applications

Microphone
Preamplitier

Mag. Phono

Preamplifier

Auxiliary

Preamplifier

Bridging

transformer

Line Matching

Transformer

Low Z MIC

with Low & High filters

Low Z MIC
with Low & High filters
and remote volume
control facilities

Low Z MIC
with Low & High filters
and MUTE

Low Z MIC
with Low-cut filter

Low Z MIC

with Low-cut filter
and remote volume
control facilities

Low Z MIC

with Low-cut filter
and MUTE

High Z MIC

with Low-cut filter

———

with MUTE

with MUTE

with remote volume
control facilities

with MUTE

———

with MUTE

with Signal Activating

Mute

Paging Input

Line Output

Tone Signal
Generator

1 kHz Sine Wave

Buzzer/Yelp

One Tone  Continuous
Chime Chime

Module

Types

H-01 series

H-21

H-31

H-02 series

H-22

H-32

H-03 series

E-01 series

E-11 series

X-01 series

X-11 series

X-21

B-01 series

B-11 series

L-01 series

L-11

L-41

I-01

T-01  series

S-01

S-02

S-03

Specifications

Source

Impedance

Balanced

200 ohms

Unbalanced
50k ohms

Unbalanced

50k ohms

Unbalanced
220k ohms

Balanced
10k ohms

Balanced
600 ohms

Balanced
600 ohms

[Output

Balanced
600 ohms]

Input Sensitivity

for Rated Output (100 mV)

nominal 1.0 

mV

adjustable 0.25~25 mV

nominal 3.2 

mV

adjustable 0.8~8.0 mV

nominal 3.2 

mV

adjustable 2.0~5.0 mV

nominal 100 

mV

adjustable 100~3,200 mV

125mV

125mV

125mV  [Min. 1 5 mV to activate]

nominal 3.2V
adjustable 3.2~10V

Gain

nominal 40 

dB

adjustable 52~32 dB

nominal 30 

dB

adjustable 42~22 dB

nominal 34 

dB

adjustable 34~26 dB

nominal 0 

dB

adjustable 0~—30 dB

—1dB

—2dB

nominal — 

30 

dB

adjustable —30~— 40 dB

nominal 20 

dB

(1.0V output)

adjustable 20~4 dB

(1.0V~158 mV)

Max. Before Clip

into 10k-ohm load

at less than 0.5% THD

(1 kHz)

[Output Voltage: ]

[S-01, S-02, S-03 ]

6.3V (+16 dBv)

6.3V (+16 dBv)

6.3V (+16 dBv)

6.3V (+16 dBv)

6.3V (+16 dBv)
4.7V (+13.4 dBv)
into 600-ohm load

0.5V (-6 dBv)  0.5% THD

1 V peak to peak

1 V peak to peak

Frequency

Response

±1dB

25~20,000 Hz

20~20,000 Hz

RIAA
Equalized

20~20,000 Hz

20~20,000 Hz

20~20,000 Hz

500~20,000 Hz
Low-cut 250 Hz

30~20,000 Hz

Noise Level

[equivelent]

[ Input noise]

[ or S/N ]

—126 dBm
200 ohms
terminated

S/N 70dB

S/N 70 dB

S/N 90 dB

———

S/N 80 dB

S/N 80 dB

S/N 80 dB

S/N 80 dB

Signal

Muting

Level

———

60 dB

60 dB

———

60 dB

———

60 dB

———

60 dB

———

60 dB

Remote volume

control range

[use 10k ohms]

[potentiometer]

———

0~— 60 dB

———

0~—60dB

0~—60 dB

Controls

[pre-

settable]

1-Low cut
1-High cut
1-Gain

1-Low cut

1-Gain

1-Low cut
1-Gain

1-Gain

1-Gain

1- Sensitivity

1-Mute

1-Gain

1-Output

1-Output

1-Output

Weight

(max.)

105 gr (3.71 oz)

100 gr (3.53 oz)

105 gr (3.70 oz)

100 gr (3.53 oz)

95 gr (3.35 oz)

105 gr (3.70 oz)

60 gr (2.12 oz)

50 gr (1.76 oz)

55 gr (1.94 oz)

70 gr (2.47 oz)

75 gr (2.65 oz)

65 gr (2.29 oz)

90 gr (3.17 oz)

95 gr (3.35 oz)

90 gr (3.17 oz)

95 gr (3.35 oz)

95 gr (3.35 oz)

100 gr (3.53 oz)

100 gr (3.53 oz)

55 gr (1.94 oz)

60 gr (2.12 oz)

70 gr (2.47 oz)

Connector

H-01F

H-02F

X-01F

X-11F

B-01F

B-11F

L-01F

H-01M

H-02M

T-01M

X-01P

L-01P

T-01P

E-01R

-11R

X-01R

-11R

H-02S

E-01S

X-01S

-11S

B-01S

L-01S

L-11S

L-41S

T-01S

S-01S

X-21S

I-01S

FORNT PANEL CONTROLS AND  FEATURES

Modules with  built-in controls are  provided  in the following five

types.

GAIN CONTROL

SENSITIVITY

CONTROL (L-41S)

NOMINAL POSITION
MARK

This adjusts gain. Turn clockwise (CW)
to increase and counterclockwise (CCW)
to reduce gain.

Set the gain as low as possible, thereby,

noise can  be  reduced, and the maximum

permissible input level is raised.

This adjusts sensitivity for  muting  other

modules having MUTE function. Turn

CW to  raise and  CCW to lower sensitivity.
Setting position should depend on the

equipment connected with  L-41S.

The left figure  shows nominal

setting of controls.

LOW-CUT FILTER

CONTROL
330Hz, 6dB/oct

(max. attenuation)

MUTE DELAY

CONTROL (I-01S)

HIGH-CUT FILTER

CONTROL

4.2kHz, 6dB/oct

(max. attenuation)

This provides flat characteristics at full
CW position and attenuation in low

frequency by turning CCW. Adjust it to

obtain  proper tone quality. With  low-cut,

tone becomes clear.

This adjusts MUTE delay time which is

the duration from signal  input to  its

output.  Turn  CW to shorten and CCW

to lengthen the time.

This provides flat characteristics at full
CW position and attenuation in high

frequency by turning CCW. Adjust it to

obtain  proper tone quality. With high-

cut, tone becomes soft.

SPECIFICATIONS IN COMMON

Load impedance

Mounting

Dimensions in mm (inches)

(H) x (W) x (D)

: 10k-ohms
: Card-edge connector

: 78(3.07)x35(1.38)x88(3.46)

— 8 —

— 9 —

Summary of Contents for A-903A

Page 1: ...ormers for bridging high impedance lines the L 01 series Line Matching Transformers for matching 600 ohm lines I 01 Paging Input for combining with TOA Intercom Systems EXES 1000 EXES 5000 and EX 16 T...

Page 2: ...meter illuminates Adjust gain of INPUT 1 6 respectively Adjusts bass response Turn clockwise CW to boost and counterclockwise CCW to attenuate the bass response Tone is flat at center Adjusts treble r...

Page 3: ...connections for a booster amplifier or a tape recorder The input impedances of the equipment should be of more than 10k ohms When using this terminal set LINK SWITCH to OUT position Connects to a sign...

Page 4: ...y means of the connected potentiometer H 31 and H 32 modules incorporate muting functions If a switch is connected to MUTE TERMINAL on the rear panel of the ampli fier and closed these input signals c...

Page 5: ...ange Therefore in TRANS OUTPUT the acoustic effect and frequency response characteristics may be altered In TRANS OUTPUT cut off unnecessary low frequency to obtain the best acoustic condition When co...

Page 6: ...mode Output fuse Each amplifier has an output fuse to protect the amplifier from short circuiting at the output or overloading Check the fuse when speakers connected do not sound even if the meter de...

Page 7: ...77 dB Power amplifier only 105 dB Bass 10 dB at 100 Hz Treble 10 dB at 10 kHz Controls 6 Input gain controls 1 Bass tone control 1 Power ON OFF switch 1 Tone defeat switch 1 Master gain control 1 Tre...

Page 8: ...ith TOA INTERCOM SYSTEMS It accepts paging signals from the intercom station A group of special signal generating modules is also available for catching attention before announcement and testing withi...

Page 9: ...B S N 70 dB S N 90 dB S N 80 dB S N 80 dB S N 80 dB S N 80 dB Signal Muting Level 60 dB 60 dB 60 dB 60 dB 60 dB 60 dB Remote volume control range use 10k ohms potentiometer 0 60 dB 0 60dB 0 60dB Contr...

Page 10: ...Diagrams Plug in Modules H 01 Series H 21S H 31S H 02 Series H 22S H 32S H 03 Series E 01 Series E 11 Series X 01 Series X 11 Series X 21S B 01 Series B 11 Series L 01 Series L 11S L 41S T 01 Series S...

Page 11: ...ol of module and the input volume control of the corresponding input so that an appropriate sound level may be obtained through the remote volume control T 01 SERIES BALANCED 600 ohm LINE OUTPUT MODUL...

Page 12: ...of R and T Lines R line Approx 9mA DC plus audio signals of 30dBm max T line Approx 9mA DC Rack mounting Brackets Silver Perforated Panel Silver A 906A A 912A P 906A P 912A P 924 M 900A A 903A HOW TO...

Page 13: ...Schematic A 903A 13...

Page 14: ...Schematic A 906A TOA NEW 900 SERIES 14...

Page 15: ...Schematic A 912A...

Reviews: