4.2. Rear

8. AC Power Cord

Connects to an AC power source.

9. DC Terminals

Connect to a DC power supply of 12V.

10. Output Terminals

Connect to speakers. When connecting
speakers, use only one of the speaker output
terminals, low or high impedance.

11. Terminal Cover

To avoid electric shock due to high voltage from
output terminals, replace the terminal cover after
connection completion.

12. AUX Input Terminals 

–20 dBV (100 mV), 10 k

Ω

, unbalanced,

monaural RCA pin jacks. Accept external
equipment output signals. (Refer to Input
Connection for details.) 

13. MIC 1, MIC 2 and MIC 3 Inputs

–60 dBV (1 mV), 600 

Ω

, unbalanced.

Because microphone input is unbalanced type,
use a single pole phone plug. (Refer to Input
Connection for details.) 

14. Muting Level Control

Adjusts the background music level 0 – 30 dB to
be automatically reduced when priority function
is operated.

15. Ground Terminal

Connects to ground (earth) to avoid electric
shock.

0 dBV=1 V

5. MUTING FUNCTION

Mic 1 input is provided with a voice-activated muting function that overrides other Mic inputs 2 and 3, and AUX
input. (Factory default: –30 dB)

0

–30dB

MUTE ADJ

Remark:  About Mute function.

• When the audio signal is input to Mic1, the mute circuit works promptly.
• When the signal disappears, it returns to the previous state after 3 seconds.

Summary of Contents for A-230 HV

Page 1: ...uture reference 1 SAFETY PRECAUTIONS 2 2 GENERAL DESCRIPTION 3 3 FEATURES 3 4 NOMENCLATURE AND FUNCTIONS 4 1 Front 3 4 2 Rear 4 5 MUTING FUNCTION 4 6 INSTALLATION 5 7 CONNECTIONS 7 1 Input Connections...

Page 2: ...ly cord is damaged exposure of the core disconnection etc If it is malfunctioning no tone sounds To prevent a fire or electric shock never open nor remove the unit case as there are high voltage compo...

Page 3: ...ed for paging announcement or background music in schools offices shops factories mosques churches and small rooms 3 FEATURES High durability high reliability and high performance Three microphone inp...

Page 4: ...ion for details 13 MIC 1 MIC 2 and MIC 3 Inputs 60 dBV 1 mV 600 unbalanced Because microphone input is unbalanced type use a single pole phone plug Refer to Input Connection for details 14 Muting Leve...

Page 5: ...al temperature rise over 10 cm over 10 cm over 10 cm 7 2 Output Connections Be sure to replace the supplied terminal cover after connection completion Because high voltage is applied to the speaker te...

Page 6: ...mn Speaker with Matching Transformer 100 V Line Horn Speaker with Matching Transformer 12 V DC Battery 8 VOLUME CONTROL SETTINGS Output levels are adjustable with individual volume controls For music...

Page 7: ...100 V output 40 dBV 40 60 40 20 20 0 dBV Mic 60 dBV MIC3 600 60 dBV Unbalanced MIC2 600 60 dBV Unbalanced MIC1 600 60 dBV Unbalanced AUX 10 k 20 dBV Unbalanced DC Fuse PT AC Fuse 100 V 4 COM 12 V DC I...

Page 8: ...in jack Speaker Out All Speaker Outputs are Floating Balanced 100 V 330 4 11 V S N Rasio Over 60 dB MIC1 2 3 Over 70 dB AUX Tone Controls Bass 10 dB at 100 Hz Treble 10 dB at 10 kHz Muting MIC1 overri...

Reviews: