OPERATION

The boiler is fired up in 

MANUAL MODE

. To start 

MANUAL MODE

  press 

MENU

 and next  use        and          

.

When the feeder is started wait till coal is delivered to retort then stop the feeder and fire up the coal. The blower can 
be used during this operation with its whole range of power.
If there is fire in the whole retort, you can change operation mode into automatic. For this purpose press 

MENU

 and 

next      

 

-

 

START

. Operation status changes from 

STOP

 to 

FIRING UP

. The blower is working with its maximum 

power and the feeder delivers coal regularly.

o

When the 

BURNING OUT TEMPERATURE

 (35 C what is set by producer) is exceeded controller starts 

HEATING

.  

If maximum and minimum power of the blower are different the quantity of delivered air and fuel decreases (feeder 
operation time is automatically reduced) as the temperature is drawing near the value preset by user and increases as 
the temperature is drawing away. 
When the preset temperature is exceeded, the controller changes to 

HOLD

 mode. The feeder and blower begin 

periodical operation to keep fire on. Whereas, there is possibility to stop blower as in case of using the sawdust as 
solid fuel.
If the boiler temperature decreases, controller changes over to 

HEATING

.   If the boiler temperature drops below 

the value of 

BURNING OUT TEMPERATURE

 controller changes to 

STOP

 status.   However controller cannot 

change to 

STOP

, if the 

FIRING UP

 time has not been completed since pressing 

START

, that is setting of 1 hour 

- made by producer.
The controller operation can be stopped at any time by pressing             

 

-

 

STOP

.  In 

STOP

 status the blower 

and feeder are stopped.
The CH pump and TW feeding pump control is accordingly relative to the temperatures of boiler and TW container 
in each operation mode.

RESETING

The flickery arrows   

!

@

,  

$

,  

#

  and  

)

   inform which button must be used to operate 

MENU

 and make any 

resetting.

       

and

       

are for parameter changing 

       

and

       

are for MENU navigation

The 

BOILER TEMPERATURE

 resetting is being made on the main display. 

The other settings can be changed after pressing 

MENU

Displays after pressing 

MENU

!a@  WARM WATER  
        

  TEMP: 45)*    

 

!b@      SEASON  

  

WINTER)

 

!c@      MANUAL 

$START$   

 

 

a) TW(tap water) container temperature

b) the season edition

WINTER

     - central heating and tap water  pumps control

SUMMER

 - tap water pump control only 

c) 

MANUAL MODE

 ON

Pressing 

MENU

 while any parameter is being edited, returns 

to the 

MAIN DISPLAY

. If the operator makes any 

modifications the controller will ask if those modifications are 
to be entered to memory. If there is no reaction during 1 minute, 
controller returns to 

MAIN DISPLAY

 and does not introduce 

any new data.