OPERATION
The boiler is fired up in
MANUAL MODE
. To start
MANUAL MODE
press
MENU
and next use and
.
When the feeder is started wait till coal is delivered to retort then stop the feeder and fire up the coal. The blower can
be used during this operation with its whole range of power.
If there is fire in the whole retort, you can change operation mode into automatic. For this purpose press
MENU
and
next
-
START
. Operation status changes from
STOP
to
FIRING UP
. The blower is working with its maximum
power and the feeder delivers coal regularly.
o
When the
BURNING OUT TEMPERATURE
(35 C what is set by producer) is exceeded controller starts
HEATING
.
If maximum and minimum power of the blower are different the quantity of delivered air and fuel decreases (feeder
operation time is automatically reduced) as the temperature is drawing near the value preset by user and increases as
the temperature is drawing away.
When the preset temperature is exceeded, the controller changes to
HOLD
mode. The feeder and blower begin
periodical operation to keep fire on. Whereas, there is possibility to stop blower as in case of using the sawdust as
solid fuel.
If the boiler temperature decreases, controller changes over to
HEATING
. If the boiler temperature drops below
the value of
BURNING OUT TEMPERATURE
controller changes to
STOP
status. However controller cannot
change to
STOP
, if the
FIRING UP
time has not been completed since pressing
START
, that is setting of 1 hour
- made by producer.
The controller operation can be stopped at any time by pressing
-
STOP
. In
STOP
status the blower
and feeder are stopped.
The CH pump and TW feeding pump control is accordingly relative to the temperatures of boiler and TW container
in each operation mode.
RESETING
The flickery arrows
!
,
@
,
$
,
#
and
)
inform which button must be used to operate
MENU
and make any
resetting.
and
are for parameter changing
and
are for MENU navigation
The
BOILER TEMPERATURE
resetting is being made on the main display.
The other settings can be changed after pressing
MENU
.
Displays after pressing
MENU
!a@ WARM WATER
TEMP: 45)*
!b@ SEASON
WINTER)
!c@ MANUAL
$START$
a) TW(tap water) container temperature
b) the season edition
WINTER
- central heating and tap water pumps control
SUMMER
- tap water pump control only
c)
MANUAL MODE
ON
Pressing
MENU
while any parameter is being edited, returns
to the
MAIN DISPLAY
. If the operator makes any
modifications the controller will ask if those modifications are
to be entered to memory. If there is no reaction during 1 minute,
controller returns to
MAIN DISPLAY
and does not introduce
any new data.