TMIO Connect IO PS301SS00 Installation Instructions Manual Download Page 3

Designed and manufactured in the USA with pride by TMIO, LLC • Chattanooga, TN • US toll-free +1.800.881.TMIO (8646) • www.tmio.com

Connect Io

TM

, Intelligent Oven

TM

, Intelligent Ovens

TM

, Green Clean

TM

, and TMIO

®

 are registered trademarks of TMIO, LLC.

ELECTRICAL REQUIREMENTS

The 

Connect Io Intelligent Oven

 requires a 

separate, grounded 4-wire, 40V (AC), 50 Amp 

service with its own circuit breaker.

Wire sizes and connections must conform

 with the 

rating of the appliance and to the requirements 

of the National Electrical Code, ANSI/NFPA 70 

- latest edition, or Canadian Electrical Code, CSA 

C22.1-1982 and C22.2 No. 01982 - latest edition, 

and all local codes and ordinances.

Oven must be connected to the proper 

electrical voltage and frequency

 as specified 

on the model/serial rating plate (located 

behind the louvered refrigeration panel).

Oven must be connected to grounded metal 

permanent wiring system.

  Check with a 

qualified electrician to make sure the oven is 

properly grounded.

Do not ground to a gas pipe.

Do not use an extension cord with this 

appliance, because this may result in 

electrical shock or other personal injury.

This unit is equipped with a No. 10 ground wire in 

the conduit.

The electrical conduit must be kept to the top left 

for a flush installation.  

Never cut the conduit.

Connect the flexible armored cable directly 

to 4-wire, 240V household service. If codes 

permit and separate grounding wiring is used, 

we recommend that a qualified electrician 

determine the grounding path and that the wire 

gauge is in accordance with local codes.

Junction boxes installed on rear wall behind oven 

must be recessed

 and located at the upper left-

hand corner of the cabinet.

A UL-Listed conduit connector must be provided 

at the junction box.

Do not install a fuse in the neutral or grounding 

circuit.  We recommend a time-delayed fuse or 

circuit breaker.  Connect directly to the fused 

disconnect (or circuit breaker box) through 

flexible armored, or non-metallic sheathed, 

copper cable (with grounding wire).

INTERNET & NETWORK

Electrical Specifications:

•  Maximum Amp Usage: 

46.7A

•  Preheat Rating: 

500W

•  Broil Element Rating: 

00W

•  Baking Element Rating: 

000W

•  Convection Element Rating, 

1650W

IMPORTANT if location 

utilizes aluminum wiring:

• Connect the aluminum 

wiring to the copper wire using 

special connectors designed 

and UL listed for joining 

aluminum to copper.

• Aluminum/copper 

connection must conform 

with local codes and industry 

accepted wiring practice.

A broadband (DSL or cable modem) Internet 

connection is required.

  Dial-up Internet services 

are not supported.

The oven either can be connected to a home 
network or connected directly to an Internet Service 
Providers’ (ISP’s) network box inside the home.

We recommend running a CAT5 cable to 
the back of the oven, where a RJ45 network 
connector is mounted.

NOTE:  If the oven is not 

connected to the Internet, it will 

still cook and refrigerate, but all 

connections to outside the home 

will be unavailable.

The oven’s RJ45 connector enables direct hard-
wiring either ethernet or wireless bridge connections.

The oven will configure its settings via DHCP 

automatically.

  If your network environment is not 

configured to handle DHCP, you must manually 
configure the oven Internet settings by entering:  
(1) the IP address, (2) network mask, (3) the 
gateway IP address, and (4) DNS server address.

i

i

Summary of Contents for Connect IO PS301SS00

Page 1: ...rements 3 Internet Network 4 Product Dimensions 5 Cabinet Dimensions 6 Cabinet Requirements 7 13 Installation Steps Final Checklist 14 Cleaning Your Oven 14 More Information 14 Customer Service IMPORT...

Page 2: ...eft rear corner of the oven cabinet and or sheet rock to enable the 4 wire oven electrical cord to pass through the cabinet and connect to the household electrical supply See Cabinet Dimensions page 5...

Page 3: ...stalled on rear wall behind oven must be recessed and located at the upper left hand corner of the cabinet A UL Listed conduit connector must be provided at the junction box Do not install a fuse in t...

Page 4: ...nection is located at the rear of the oven If a wireless bridge connection is preferred or if local routers or adaptors are used then use the 2 socket 120V electrical outlet provided ALIGNMENT Align t...

Page 5: ...IO are registered trademarks of TMIO LLC CABINET DIMENSIONS Cabinet Front View Cabinet Right View 30 76 2 cm minimum cabinet width 33 83 8 cm recommended 2 5 1 cm minimum top of cutout to bottom of up...

Page 6: ...t mounting screws provided ELECTRICAL LOCATION Make a cutout for the electrical supply at the UPPER LEFT of the cabinet using the cabinet front as the origin point of reference See figure right INTERN...

Page 7: ...ng packaging materials WARNING Never use door handles or any portion of the control panel or trim for lifting the oven This may cause severe damage to the product lCarefully remove plastic wrapping po...

Page 8: ...or before installing the oven to ensure handle oven door are NOT used to lift oven Special handle slots hand grips located on both sides of the oven are designed to assist with moving the oven Squarel...

Page 9: ...re from the household power supply with the red wire in the oven conduit using twist on connectors m Follow local codes and ordinances to complete the neutral and ground connection according to the fo...

Page 10: ...one number STEP 4 Network Connections INSTALLATION STEPS n continued You may want to enter the number from which you will be calling the oven most frequently When you call the TMIO Remote Access Numbe...

Page 11: ...abinet without any obstruction l Make sure the electrical supply cable is routed on top of the oven as shown in the drawing right A string may be useful to secure the cable to the top of the oven whil...

Page 12: ...ademarks of TMIO LLC j Attach the louvered refrigeration panel to the bottom front face located below the lower oven see figure right Ensure that the refrigeration panel vents are not blocked or damag...

Page 13: ...Final Checklist INSTALLATION STEPS DOOR ATTACHMENT i i Place both hinge arms back in the slots of the hinge receiver Push the hinge arms in as far as they will go until the bottom of the door meets th...

Page 14: ...ement parts may be used in performing service on the Connect Io Intelligent Oven Do not repair or replace any part of the appliance unless specifically recommended in the Connect Io Use Care Manual Al...

Page 15: ...www tmio com 1220A Flynn St Chattanooga TN 37403 USA Connect IoTM Intelligent OvenTM Model PS302SS00 Professional Series Refrigerated Internet Controlled 30 Electric Built In Double Wall Oven Install...

Reviews: