W W W . T M G I N D U S T R I A L . C O M
P 9 / 14
T o l l F r e e : 1 - 8 7 7 - 7 6 1 - 2 8 1 9
Figure 7
Step 4 : Install the color iron tile
Before installation, ensure that the distance between centers of each collapse is 1500mm.
Install the first row of colored steel tiles from the top end. The center of the colored steel
tiles must be aligned with the midpoint of the top arch tube (you can mark the center of
the top arch tube with a line). The extension size of both ends is 50mm. The size of the
middle cross overlap position is 95mm, and the cross overlap position needs to be coated
with waterproof silicon sealant. All color steel tiles are fixed on the truss with (#18) self
tapping screws (refer to figure 8).
Parts used in this step :
- (30) Metal sheet (#7)
- (60) Metal sheet (#8)
- (340) Self tapping screw (#18)
- (4) Waterproof silicon sealant (#16)