ProPlex IQ One user manual version 1.6.8 122216
6
3.
S
ETUP
F
USE
R
EPLACEMENT
The fuse for this fixture is located on the back of the unit. ProPlex IQ devices use a 1A, 250V, 5x20mm
(0.2x0.8 in.) cylindrical fuse. To replace fuse:
1. With a screwdriver turn the fuse cap counter-clockwise to remove fuse cap with fuse.
2. Replace fuse attached to fuse cap.
3. Reinsert fuse cap with new fuse and tighten clockwise.
E
THERNET
C
ONNECTIONS
The Ethernet connector is Neutrik
®
EtherCon RJ45. Ethernet is 10/100 Base-T with auto-negotiation.
Ethernet connector has two status LEDs. Green indicates link state – if on, link is established and
communication can proceed. If Ethernet cable is connected, but Link LED is off, check cable or device at
other end of Ethernet cable. Active LED shows data activity – every time Ethernet packet is sent or
received, LED blinks once.
F
IBRE
O
PTIC
C
ONNECTIONS
The IQ One 8 Optical RackMount has one fibre optic port with Neutrik OpticalCon QUAD chassis connector.
The optical port accepts 50/125µm multi-mode optical fibre with Neutrik OpticalCon QUAD connectors. Max
cable length is 550m. Three RJ45 Ethernet ports are all 10/100/1000 Base-T with max cable length 100m.
All Ethernet ports are connected and switched internally so all data is regenerated to all ports. For example,
if optical fibre cable is run to FOH, the Ethernet ports can be used to extend the network by connecting to
other equipment.
Disconnect the power cord before replacing fuse.
Always replace with the appropriate fuse..