background image

 

EZ-LAN Unity 20 user manual version 3.3.3  120919  

 

 

   

- 8 -

 

To change the VLAN group assignment, hold the Group Select button for few seconds to unlock the 
group. The display will begin flashing. Then press the button to cycle trough all available groups. After 
the desired group is selected, wait for a few seconds for this new group to be saved and for the switch 
to internally reconfigure the port group. The display will stop flashing.  
 
All of the ports within the same group are linked together and they can exchange data, while other 
ports in other groups are not connected. 
 
The same group can appear multiple times in network, even in the same unit – all ports can even be 
set to the same group.    

 

H

ARDWARE 

I

NFORMATION

 

 

Each Ethernet port has status LEDs that indicate data activity (IN or OUT).  

 

If the status LED is blinking, the Ethernet port is receiving signal. 

 

If the status LED is not blinking, the Ethernet port is not receiving signal. 

 

All ports have separate optical and galvanic isolation. 

 

Ethernet connectors are Neutrik EtherCon RJ45.   

 

Ethernet is 10/100/1000 Base-TX with auto-negotiation. 
 

3. Optional Rear RackMount Kit 

 

An optional Rear RackMount Kit is available for 8-point mounting within racks of various sizes, providing 
greater physical integrity to the EZ-LAN enclosure.  This is particularly beneficial if the rack is transported.   

 

Summary of Contents for ProPlex EZ-LAN Unity 20

Page 1: ...EZ LAN Unity 20 USER MANUAL TMB 24 7 Technical Support US Canada 1 818 794 1286 Toll Free 1 877 862 3833 877 TMB DUDE UK 44 0 20 8574 9739 Toll Free 0800 652 5418 e mail techsupport tmb com ...

Page 2: ...NSTRUCTIONS 3 FUSE REPLACEMENT 4 PANEL FRONT 4 PANEL BACK 4 NETWORK EXAMPLES 5 2 OPERATION 7 CONFIGURATION 7 GROUP CHANGING 7 HARDWARE INFORMATION 8 3 OPTIONAL REAR RACKMOUNT KIT 8 CONFIGURATION 8 MOUNTING 9 4 APPENDIX 10 LIMITED WARRANTY 10 RETURN PROCEDURE 10 TECHNICAL SUPPORT 11 TECHNICAL SPECIFICATIONS 11 ...

Page 3: ...gns of mishandling Save the carton and all packing materials In the event that a unit must be returned to the factory it is important that it be returned in the original factory box and packing POWER REQUIREMENTS Before powering the unit make sure the line voltage is within the range of accepted voltages This unit accommodates 100 240VAC 50 60Hz All units must be powered directly from a switched c...

Page 4: ...r disconnect power cord by pulling or tugging on the cord FUSE REPLACEMENT The EZ LAN uses a 1 0A 250V barrel fuse 5x20mm 0 2x0 8 in To replace fuse 1 With a screwdriver turn the fuse cap counter clockwise to remove fuse cap with fuse 2 Replace fuse attached to fuse cap 3 Reinsert fuse cap with new fuse and tighten clockwise UNIT PANELS FRONT BACK ...

Page 5: ...EZ LAN Unity 20 user manual version 3 3 3 120919 5 NETWORK EXAMPLES diagram continued next page ...

Page 6: ...EZ LAN Unity 20 user manual version 3 3 3 120919 6 ...

Page 7: ...th multiple EZ LANs VLAN Groups Each EZ LAN can have up to 4 different VLAN groups A VLAN can be defined as a separate network that is isolated from other networks on the same EZ LAN VLANS can be chosen by pressing the VLAN group button on a group of connectors and choosing group 1 through 9 These can be used to network multiple devices together while keeping them separate from other groups of dev...

Page 8: ...ted The same group can appear multiple times in network even in the same unit all ports can even be set to the same group HARDWARE INFORMATION Each Ethernet port has status LEDs that indicate data activity IN or OUT If the status LED is blinking the Ethernet port is receiving signal If the status LED is not blinking the Ethernet port is not receiving signal All ports have separate optical and galv...

Page 9: ...o the enclosure with the option of two positions both using four screws hardware included Never use less than four screws per side when attaching the bracket to the EZ LAN chassis The rear Ear Flange attaches to both the Side Bracket and directly to the rear rack rail The side of the Ear Flange which attaches to the Side Bracket has extra elongated screw slots for to allow for fine adjustments as ...

Page 10: ...andise Authorization RMA Number must be obtained from TMB prior to return of any defective merchandise for warranty or non warranty repair For all repairs please contact TMB Tech Support Repair using the contact information below or email TechSupportRepairNA tmb com US UK 527 Park Ave 21 Armstrong Way San Fernando CA 91340 Southall UB2 4SD England Tel 1 818 899 8818 Tel 44 0 20 8574 9700 Fax 1 818...

Page 11: ...ns WEIGHT DIMENSIONS WIDTH 19 IN 483 MM DEPTH 12 IN 305 MM HEIGHT 3 5 IN 90 MM WEIGHT 10 8 LB 4 9 KG EIA RACK UNITS 19 2U POWER OPERATING VOLTAGE 100 240V 50 60Hz POWER CONSUMPTION 10W MAX THERMAL OPERATING TEMPERATURE 20 TO 40 C COOLING Convection CONTROL BASE TX 10 100 1000 PORTS 18 FIBRE OPTIC LINK PORTS 2 OPTICAL CONNECTORS OPTICALCON QUAD DUO OPTION AVAILABLE ETHERNET CONNECTORS ETHERCON RJ45...