172-65203MA-02 (A-BD2) 21 Apr 2010
Installation
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
Do not use excessive force when connecting threaded pipes to the
product. Over-tightening may cause breakage leading to fluid
discharge, which may cause burns or other injury.
CAUTION
Note: For products with socket weld connections, electric weld with a single pass. As
internal parts are not damaged by the welding process if limited to a single
pass, there is no need to remove them before welding.
Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
1. Before installation, be sure to remove all protective seals.
2. Before installing the trap, blow out the inlet piping to remove any piping scraps, dirt
and oil. Close the inlet valve after blowdown.
3. Install the trap so the arrow on the trap is pointing in the direction of condensate
flow.
4. The trap may be installed either horizontally or vertically; there are no restrictions
on the direction of installation. (Fix the trap securely in place.)
5. Connect the outlet piping.
6. Open the inlet valve and check to make sure that the trap functions properly.
If there is a problem, determine the cause by using the “Troubleshooting” section in
this manual.