TLC SEC150 Introduction Download Page 2

 

FIGURE 3

 

 

LAMP INSTALLATION

 

 

CAUTION 

: Always handle quartz halogen lamps with 

a  soft  cloth.    Do  not  touch  the  lamp  with  your  bare 
hand as it will shorten the life of the lamp.   
 
(1)    Do not touch the floodlight while it is in use or still 
        hot. Allow it to cool before touching it. 
(2)    Do not use halogen lamps rated higher than  150 

watts for SEC150 and 500 watts for SEC500. 

(3)    Disconnect  the  power  cord  or  wall  switch.   

Unscrew  retaining  screw  at  the  top  of  the  unit. 
This will release the front surround.(FIGURE 4) 

(4)     

 

FIGURE 4 

(5)    Raise  front  surround.    Lift  off  retaining 

lugs.(FIGURE 5) 

 

FIGURE 5 

(6)    Unwrap  the  halogen  lamp,  taking  care  that  the 

fingers do not touch the glass. Push one end into 
either  of  the  spring  loaded  sockets.    Locate 
other  end  on  other  socket  and  release.(FIGURE 
6) 

 

             

 

FIGURE 6 

 

(7)    Carefully replace front surround making sure that 

the seal is correctly positioned.    Screw up firmly. 
(FIGURE 7) DO NOT OVER TIGHTEN. 

   

FIGURE 7 

 

INSTALLATION

 

To  facilitate  installation  select  a  location  for  the  unit 
based on the coverage angles shown in FIGURE 8. 
 

 

UNIT(M) 

COVERAGE ANGLES

 

FIGURE 8 

 

Install  a  wall  switch  adjacent  to  the  power  source. 
(FIGURE  9)    This  helps

 

you  operate  with  ease.  See 

Operation for further information. 

 

FIGURE 9

 

WIRING INSTRUCTION

 

 

(1)    Switch off the power source. 
(2)    Remove the mounting bracket from the floodlight. 

Drill the wall and screw the bracket onto the wall   
using  suitable  plastic  wall  plugs  and  screws. 
Check that the bracket is securely fitted on the   

wall. 

Note: Do not at this stage re-attach the 
floodlight to the bracket. 