7
2.1.6.1 PITCH (concert pitch)
The concert pitch is the principal reference tone for all other tones of a particular tuning task. It is
linked to the tone a’ and is adjustable from 220 to 880 Hz in steps of 0.01Hz. If both Value buttons
are pressed simultaneously, the concert pitch is automatically adjusted to the tone played at that
moment.
2.1.6.2 CENTS (cent mode)
The target frequency of the tuning device can be transformed by +- 150 cent in steps of 0.1 cent. If
both Value buttons are pressed, the cent mode is automatically adjusted to the tone played at that
moment. The cent mode is automatically changed by several of the instrument programs. More
details on this subject are found in chapter: 2.2.
2.1.6.3 BEAT (beats)
The beats to the actual target frequency can be selected through this function. Adju- 100.0
Hz in steps of 0.1 Hz.
2.1.6.4 INTVL (Interval)
The target frequency can be shifted by one purely tuned interval. Modes: SECOND, THIRD,
FIFTH, SEPTIM ...
2.1.6.5 h/16 (16th semitonestep)
The target frequency can be changed by 16th part of a semitone. (+/-32 16th semitones)
2.1.6.6 BARGR (mode of bar display)
Here you will control the mode of the bar display (additional see chapter 2.3.3.8).:
Level:
Indication of frequency deviation and partial tone level.
Full:
Indication of frequency deviation.
Sen:
Indication of frequency deviation,
degree centigrade and thermosensor cents (only if thermosensor connected)
2.1.6.7 AMPL (Amplification)
The amplification of the signal coming from the microphone can be adjusted by this function. Ad-
justable from 1 to 8. If both “Value” buttons are pressed simultaneously, the amplification is auto-
matically adapted to the tone played at that moment. Exception: Several of the instrument pro-
grams change the amplification automatically depending on the height of the tone.
2.1.6.8 RESOL (resolution)
The resolution of the “bar display” for frequency deviations can be adjusted through this setting.
A setting of 10 means a full scale of 10 Cent.
A setting of 200 means a full scale of 200 Cent.
Adjustable 10…200 Cent.
2.1.6.9 GATE (gate time)
Small value: The display reacts very rapidly, whereby the spreading of the measurement values
are relatively large-scale.
High value: The display reactions become slower, the spreading of the measurement values is
accordingly smaller.
Adjustable 50..1000 milliseconds
()