28
EMS Setup Menu
RPM Setting
•
Menu RPM setting
•
Pulses Per Rev
•
Reduction ratio
RPM setting
You can set number of pulses per rev and you can set
reduction ratio.
In both cases the underlined number you can change by
rotating the right-hand knob. If you get the required
number, just press the knob and the underscore will
skip on to the next number. Press “Set” to enter the new
value. Press “Cancel” to skip previous menu.
NOTE:
If you are unable to install a sensor directly on your engine and the
location of your sensor is affected by a reduction ratio. It is then
necessary to enter the correct reduction ratio. If this function is not
used then preset reduction ratio to 1.00.