Voting function 

z

 

Sign in 

The indicator lamp "ATTEND" will flash when conference sign in start. Delegates sign in by 

key-press and the "ATTEND" indicator in the vote unit will light, it means that delegates have 

sign in. Then the vote unit can achieve other function. 

z

 

Vote 

There are five buttons on the vote unit, the first three are: yes/no/abstain. Each button has the 

corresponding indicator lamp. After voting starts, delegate can press the corresponding button 

according to their willing. The delegate can re-vote before the voting finishing if they want to 

revise their vote; the voting results are subject to last key-press. 

z

 

Elect 

The five buttons on the vote unit stand for Candidate 1/2/3/4/5. Each button has the 

corresponding indicator lamp. There are three kinds elect mode optional (Three select three, five 

select one, five select five). As election starts, delegate can press the corresponding button 

according to their willing. The delegate can re-elect before the election finishing if they want to 

revise their elect; the election results are subject to last key-press. 

z

 

Audience response 

When conference start audience response, five button on the vote unit means: "--" (0),   

"-"(25), "0" (50), "+" (75), "++" (100). 

2.    Video camera auto-track function 

3.  Discuss mode 

z

 

Free mode:  All the microphones can turn on freely at the same time but PRIO ket of 

chairman unit has effect on all delegate unit. operator and chairman unit can turn off the 

delegate unit any time. 

z

 

FIFO mode:  first in, first out. Operator can set the number of microphone that can be 

Turned on at the same time in this mode. When talking units reach the number, the first on 

microphone will turned off automatically to keep the limit microphone number. 

z

 

Limit mode: Operator can set the number of microphone that can be turned on at same time. 

When talking units reach the number, the latter can be turned on only after the earlier turned 

off. 

z

 

Auto-Meeting mode:  Operator can set the limit time (1-250 minutes) of each delegate's 

speaking. Only one microphone can be turned on at same time, but all delegates microphone 

can wait to talk with requesting. The first delegate microphone can make a speech without 

waiting and requesting.   The system will start to count limit time automatically after the 

microphone turned on and this microphone will turned off automatically after reach the limit 

time. If there are some delegates wait to speaking, the delegate microphone will turn on one 

by one, and the limit time start to count automatically. The operator also can force to turn off 

the microphone by control panel, and the next microphone can start to speak. 

z

 

Request mode: Delegates need press "Talk" on the microphone to request speaking, all the   

microphone need the operator's permit to make a speech 

z

 

Appoint addresser: Operator    can appoint any mic turn on and turn off according to their   

Willing 

VI.  System connection and debug 

1. 

Preset conference main unit in racks or on the council board, chairman and delegate units on 

Summary of Contents for MC-300A

Page 1: ...Public address systems Commercial sound systems MC 300A Conference system www t koko com...

Page 2: ...ntity z Chairman units have priority control over conference sequence z Chairman units can be connected as series anywhere z Easy connection and maintenance with T shape cable serial connection Shield...

Page 3: ...ate microphone are turned off but can be turned on again after chairman microphone press Priority button operation in computer z Auto off It can be choosen whether microphone will turn off automatical...

Page 4: ...n unit can turn off delegate unit 7 Microphone switch TALK 8 Voting key 9 LED 10 IC CARD INTER 11 LINE Chairman Unit Delegate Unit III Extension unit function When attendance units reach to 60 pcs one...

Page 5: ...and chairman unit can turn off the delegate unit any time z FIFO mode first in first out Operator can set the number of microphone that can be Turned on at the same time in this mode When talking uni...

Page 6: ...r to REC port of main unit 14 After connect the system well turn off the power of the system the main unit and debug the main unit volume VOL to minimum position other volume control to middle positio...

Page 7: ...sk Min 15 MB free hard disk memory Drives CD ROM or DVD ROM drive drive for data backup e g floppy disk drive CD recorder or ZIP drive Interfaces At least one free RS 232 interface serial interface So...

Page 8: ...d setting Video display is used to transmit the signals of voting or electing results We recommend customer to use our video display to configure the computer 1 Specification of the video display card...

Page 9: ...V or project to the video display card 5 Please click right mouse on desktop choose Properties to enter the Display properties panel 6 Click Settings to enter the setting panel choose set the Screen r...

Page 10: ...ay normally please resetting as process 5 and 6 then click Advanced icon to enter the multiple monitors choose monitor to debug the setting Part C Operation Log on 1 Make sure the software Dongle conn...

Page 11: ...e message to suggest user check the connection and power Fig 4 The software will enter the main panel after user chooses and check the communication port Main panel of the software There are seven par...

Page 12: ...software fig 7 4 The sign in results will displayed in the sub screen if user click fig 8 5 If any delegates not sign in or late for sign in user can click then the not sign in person can resign in by...

Page 13: ...in the box then click Modify name icon d Add please input the delegate name in the box then click Add icon to add the delegate in the list e Delete the last user can delete the last delegate in the l...

Page 14: ...5 select 1 only one candidate can be selected among the 5 candidates Single ballot e 5 select 5 5 candidates can be selected at same time Multiple ballot f Grade mode To mark a score for a proposal 0...

Page 15: ...the limit time and pass ratio please click Vote Elect Start to start voting or electing and the software will start to count the limit time automatically user can end the vote elect by Vote Elect End...

Page 16: ...to turn off all the microphone in the system d Mic Reset System microphone will be reset and initialized to the first time that system turn on 2 This part is for user setting the working mode of the s...

Page 17: ...d requesting The system will start to count limit time automatically after the microphone turned on and this microphone will turned off automatically after reach the limit time If there are some deleg...

Page 18: ...microphone or input the Mic ID in the textbox then click turn off that microphone will be off c Turn on Operator need to click the microphone icon the icon will display the microphone ID or delegate n...

Page 19: ...not FIFO please set this mode in meeting control panel first we recommend FIFO number is 1 3 Turn on one microphone by Talk key first or input the Mic ID in the Mic number textbox then click Turn on t...

Page 20: ...r display the contents in the meeting fig 27 1 Open the Sub screen 2 Size Please select the sub screen resolution size in the left part of this control panel Projector usually select 800 600 TV usuall...

Page 21: ...ngress Government enterprises etc The delegates can register vote elect and participate in the democratic meeting on seat This system is with multiple functional reliable steady and attractive designs...

Page 22: ...voting results are subject to the button pressing at the last time 4 Election There are five buttons on the vote unit candidate 1 2 3 4 5 Each button has the corresponding indicator lamp After electi...

Page 23: ...The system can support 4096 vote unit by processor series connecting This voting system is suitable for the People s Congress Government enterprises etc The system is easy to install and operate 1 PO...

Page 24: ...tracing other spokesman s position automatically This system include meeting host central processor chairman unit delegate unit high speed dome software for system controlling and computer etc A Meet...

Page 25: ...ut 1 output 1 Power switch 2 Power indicator 3 AV1 4 AV2 5 AV3 6 AV4 7 Busy led 8 Data port 9 RS 232 port 10 Dome A G B A B G GND 11 V1 input 12 V2 input 13 V3 input 14 V4 input 15 Video out 16 AC pow...

Page 26: ...delegate units at 24 safe voltage 5 8P DIN plugs for T type connecting with the system 6 Built in high fidelity loudspeaker and volume regulate 7 Electric capacity type microphone equipped with winds...

Page 27: ...ion as low as 0 15 Lux Note 1 Dome port is used for connect Camera 2 There are three connectors of the camera A G B and Dome port in the video processor also have A G B connector please connect each c...

Page 28: ...and with prevention on feedback Digital display of the channels Equipped with a set of earphone Prevention on interpreter s cough Frequency Response 100 16000Hz Sensitivity 44 2dB ON OFF button on the...

Page 29: ...Schematic diagram Interpreter unit...