36
8.1.3
Default inputs and outputs
When replacing an Orbit reader with an Orion, the below table can be used:
Orbit 2
Reader 1
Description of
connection
Orion
Reader & IO-1
iProtect™
default
+5V 200mA MAX
Reader voltage
+V
GND
GND (digital ground)
C
D1 / CLK
D1 / Clock
D1
D0 / DAT
D0 / Data
D0
LED
LED
LD
⏚
Earth ground
⏚
Inputs 1
Inputs 1
Input/Output
IN0
Digital input
A1
Loop
COM 0+1
GND (digital ground)
C
C
IN1
Digital input
A2
Button
IN2
Digital input
A3
Door mode
COM 2+3
GND (digital ground)
C
IN3
Digital input
T1
Door in latch mode
Outputs 1
Outputs 1
0
Digital output
H1
Door operation
GND
GND (digital ground)
C
1
Digital output
O2
Alarm
Orbit 2
Reader 2
Description of
connection
Orion
Reader & IO-2
iProtect™
default
+5V 200mA MAX
Reader voltage
+V
GND
GND (digital ground)
C
D1 / CLK
D1 / Clock
D1
D0 / DAT
D0 / Data
D0
LED
LED
LD
⏚
Earth ground
⏚
Inputs 2
Inputs 2
Input/Output
IN0
Digital input
A4
Loop
COM 0+1
GND (digital ground)
C
C
IN1
Digital input
A5
Button
IN2
Digital input
A6
Door mode
COM 2+3
GND (digital ground)
C
IN3
Digital input
T2
Door in latch
mode
Outputs 2
Outputs 2
0
Door Output
H2
Door operation
GND
GND (digital ground)
C
1
Alarm output
O5
Alarm
Summary of Contents for KEYPROCESSOR Orion
Page 1: ...1 Pluto Orion Doc no 01052018 Modular controller line Installation instructions ...
Page 4: ...4 ...
Page 58: ...58 14 2 72000206 Pluto Orion with Sirius RS485 and IO ...
Page 59: ...59 14 3 72000202 Pluto Orion with Sirius clock data Wiegand and I O ...
Page 60: ...60 14 4 72000207 Pluto Orion with IO Sirius Clock data Wiegand and Orbits ...
Page 61: ...61 14 5 72000304 Pluto with power supply and USB RS232 converter ...
Page 62: ...62 14 6 72000203 Pluto Orion with kpBus ...
Page 63: ...63 14 7 72000204 Orion with kpSensor bus ...
Page 64: ...64 14 8 72000602 Pluto Orion stacked with 8x RS485 Sirius i readers ...
Page 65: ...65 14 9 72000602 Pluto Orion with clock data or Wiegand readers ...
Page 66: ...66 14 10 72000602 Pluto Orion with RS485 readers kpBus combi ...