TKH security TKIM25F2S User Manual Download Page 20

User Manual - Network Mini Dome - TKIM25F2S/TKIM45F2S/TKIM25F2SM12/TKIM45F2SM12

EN

20

Figure 2-6

 

WB Setting

 interface 

 

 

 

Table 2-5 describes 

WB Setting

 parameters.   

Table 2-5

 

WB Setting

 parameters description 

Parameter

 

Meaning

 

Configuration Method

 

Mode

 

It is adjusted based on application 
scenarios to improve the fidelity of 
the image color. 
The WB modes include: 

z

 

Auto

: In automatic white balance 

(WB) mode, the system 
automatically performs white 
balance based on the monitoring 
environment. 

 

z

 

Tungsten

 

z

 

Fluorescent 

z

 

Daylight

 

z

 

Shadow

 

z

 

Manual

: In manual WB mode, 

you can manually select a WB 
mode based on the monitoring 
environment.

 

[Setting method] 
Select a value from the drop-down list. 
[Default value] 

Auto

 

Summary of Contents for TKIM25F2S

Page 1: ...User manual Network mini dome TKIM25F2S TKIM45F2S TKIM25F2SM12 TKIM45F2SM12 tkhsecurity fr V 201910 01...

Page 2: ...symbols whose meanings are described accordingly Symbol Description It alerts you to fatal dangers which if not avoided may cause deaths or severe injuries It alerts you to moderate dangers which if n...

Page 3: ...ghtning frequently occur ground the device nearby to discharge high energy such as thunder strikes in order to prevent device damage z During the outdoor installation prevent the morning or evening su...

Page 4: ...oard corrosion that can affect monitoring z Remove the power plug if the device is idle for a long time z Before unpacking check whether the fragile sticker is damaged If the fragile sticker is damage...

Page 5: ...ge the Password 1 4 Browse Video 1 4 1 Install Plugins 1 1 5 Setting Local Network Parameters 1 3DUDPHWHU 6HWWLQJ 2 1 Sensor Setting Interface 1 2 2 Time Segment 1 2 3 Image Setting 1 2 4 Scene Mode 1...

Page 6: ...21 in the address box and press Enter The login page is displayed as shown in Figure 1 1 Figure 1 1 Login page Step 2 Input the User and password z The default name and password are both admin Modify...

Page 7: ...s the elements on the main page layout Figure 1 2 Main page layout Table 1 1 Elements on the main page No Element Description 1 Real time video area Real time videos are played in this area You can al...

Page 8: ...hot the video and save the images to the specified location 14 Local record Record the video and save the file to the specified location 15 Intelligent analysis Open close the intelligent analysis 1 W...

Page 9: ...ord new password and confirmation password Step 3 Click OK Step 4 If the message Change own password success is displayed the password is successfully changed If the password fails to be changed the c...

Page 10: ...p 2 In the Internet Explorer choose Tool Internet Options Security Customer level and set Download unsigned ActiveX control and initialize and script ActiveX controls not marked as safe for scripting...

Page 11: ...re Step 1 Click the message download and install the plugin follow the prompts Step 2 During installing user should close the browser Step 3 Reopen the browser after installation 1 5 Setting Local Net...

Page 12: ...address length of 128 bits Setting method Select a value from the drop down list box Default value IPv4 DHCP The device automatically obtains the IP address from the DHCP server Setting method Click...

Page 13: ...r a value manually Default value 192 168 0 2 MTU Set the maximum value of network transmission data packets Setting method Enter a value manually NOTE The MTU value is range from 800 to 1500 the defau...

Page 14: ...wn in Figure 2 1 Figure 2 1 Sensor Setting Table 2 1 Right click setting parameters Parameter Description Setting Full screen Click it the live video will display in full screen Setting method Click S...

Page 15: ...Operation Procedure Step 1 Click in the lower left corner of Sensor Setting and choose Debug Mode Step 2 Tick Enable Step 3 Set the Start Time Step 4 Set the End Time Step 5 Click Save the message Sav...

Page 16: ...ider Default value 50 Contrast It indicates the contrast between the bright part and the dark part of an image As the value increases the contrast increases Setting method Drag the slider Default valu...

Page 17: ...cene It indicates the working mode of a camera z Outdoor It applies to outdoor scenarios z Indoor It applies to indoor scenarios Configuration method Select from the drop down list Default value Outdo...

Page 18: ...tion Configuration Method Aisle Mode The image rotates 90 degrees clockwise when aisle mode is enabled Setting method Tick the Freeze status Default value Disable 2 5 Exposure Figure 2 5 shows the Exp...

Page 19: ...to Meter area It is used to select the metering area z Whole During metering all areas of an image have an equal weight that is all areas are involved in the metering z Center pot During metering the...

Page 20: ...is adjusted based on application scenarios to improve the fidelity of the image color The WB modes include z Auto In automatic white balance WB mode the system automatically performs white balance bas...

Page 21: ...ustomized Setting method Drag the slider Default value 0 Blue Gain It indicates the gain applied to blue channels As the value increases the color temperature becomes higher This parameter is valid wh...

Page 22: ...User Manual Network Mini Dome TKIM25F2S TKIM45F2S TKIM25F2SM12 TKIM45F2SM12 EN 22 Figure 2 8 DayNight Mode 2 interface Figure 2 9 DayNight Mode 3 interface...

Page 23: ...User Manual Network Mini Dome TKIM25F2S TKIM45F2S TKIM25F2SM12 TKIM45F2SM12 EN 23 Figure 2 10 DayNight Mode 4 interface Table 2 6 describes DayNight Mode parameters...

Page 24: ...colored and the filter is in the day state preventing infrared light from entering the sensor z Night mode The image is black and white and the filter is in the night state allowing infrared light to...

Page 25: ...method Drag the slider Default value 0 IR LED z Auto The infrared lamp is enabled or disabled based on the external environment identified by the light dependent resistor LDR z ON The system enters th...

Page 26: ...11 Noise Reduction interface manual Figure 2 12 Noise Reduction interface auto Table 2 7 describes DNR parameters Table 2 7 DNR parameters description Parameter Meaning Configuration Method 2D NR Red...

Page 27: ...he noise filter is disabled When the parameter value is greater than 0 the noise filter is enabled and the system automatically adjusts the noise filter level based on the ambient brightness without e...

Page 28: ...od Tick the WDR mode and drag the slider Default value 50 HLC It provides a clearer view of an image in the highlight environment When HLC is enabled the total brightness of an image is reduced allowi...

Page 29: ...age in the fogged environment when Defog is enabled As the value increases the image becomes clearer Setting method Tick the Defog mode and drag the slider Default value 50 2 10 Zoom Focus Figure 2 14...

Page 30: ...IM25F2SM12 TKIM45F2SM12 EN 30 Parameter Meaning Configuration Method Auto Focus Once It is used to trigger auto focus Setting method Click the button Lens Initialization The lens of camera returns to...

Page 31: ...ion Local network parameters include z IP protocol z IP address z Subnet mask z Default gateway z Dynamic Host Configuration Protocol DHCP z Preferred Domain Name System DNS server z Alternate DNS ser...

Page 32: ...uses an address length of 32 bits Setting method Select a value from the drop down list box Default value IPv4 Obtain IP address automatically The device automatically obtains the IP address from the...

Page 33: ...rnate DNS Server IP address of a domain server If the preferred DNS server is faulty the device uses the alternate DNS server to resolve domain names Setting method Enter a value manually Default valu...

Page 34: ...ed z Connect the PC directly to the camera and verify that the web management system can be accessed z Run the ping command to verify that the camera is reachable The IP address is used by another dev...

Page 35: ...as an example 1 Open Internet Explorer 2 Choose Tools Internet Options 3 Click Delete The Delete Browsing History dialog box is displayed 4 Select all check boxes 5 Click Delete Login to the web manag...

Page 36: ...V 201910 01 153 rue Michel Carr 95100 Argenteuil FRANCE tel 33 0 1 30 76 30 30 info fr tkhsecurity com tkhsecurity fr...

Reviews: