Installation of the unit 

 

 

Make sure that the installation surface can support at least four times the weight of 
the unit in normal operating conditions. In case of excessive external stress 
(vibration, strong winds or impact, for example), the equipment may need 
additional means of protection. 
Proper stainless-steel hardware (grade A4 or 316) should be carefully chosen to 
fasten the unit to the surfaces. Proper tools should be used during the installation, 
in accordance to environmental requirements.  
Dome covers should be opened only by the manufacturer. 

Electrical connections (such as plugs and cords) must be protected from potential 
hazardous environmental factors (e.g. foot traffic, hitting objects). 
Pointing the camera at the sun may damage it. 
Complete the installation performing the camera connection referring to the 
manual of the camera. 
Carefully check the supply voltage marked on the label. An incorrect power supply 
voltage may damage the unit. Do not overload the terminal connection, as it may 
cause a fire or electrical shock hazard. 

 
 
 

To protect the installation for overcurrent, install a delayed fuse T (Time delay) of 
at least 4 A or fuse of 10 A max. Or equivalent resettable devices such as 
magnetothermal fuses. These ratings include inrush current for startup or 
temporary overload. It must be very quickly recognizable and readily accessible.  
For connection to the 24Vac use a multipolar cable having minimum 3x1,5 mm

2

 

(15 AWG). The mains cable must be protected. 
An all-pole mains switch with an opening distance between the contacts at least 3 
mm in each pole must be incorporated in the electrical installation. 
Make sure that the unit case is properly earthed. The Protective Earth (PE) 
connection is included in the 3p or 5p power connector. The minimum wire size is 
2.5 mm

2

 copper stranded wire. 

Fasten all the cables inside the housing with cables ties or other fixing means to 
avoid the electrical contact with surrounding parts in case cables get loose. 
Do not connect the unit to a supply circuit unless the installation is completed 

 

To maintain the certification requirements and the IP rating of the unit, adequate 
certified cable glands must be used. Each unused cable gland hole must be 
closed using a proper plug suitable for the housing marking. 
Check the proper position of the O-ring seals in their groove 
Keep the unit tightly closed when operating. 
Disconnect the equipment from the supply circuit and wait at least five minutes 
before opening. 

Summary of Contents for Siqura EX-PD24

Page 1: ...TKH TKH Security Siqura EX PD24 Installation manual 1 INT RJ SM MM Installation manual...

Page 2: ...invite you to offer your suggestions and comments by email via info tkhsecurity com Your feedback will help us to further improve our documentation How to contact us If you have any comments or querie...

Page 3: ...manual 3 Contents Contents 3 Description 4 Safe Area SA camera housing 4 Hazardous Area Ex camera housing 4 Before you continue 5 Installation of the unit 6 Installation instruction 7 INT RJ INT SM IN...

Page 4: ...net Safe Area cameras are not available with an external cable tail Hazardous Area Ex camera housing The Atex or EX camera housings require a pre installed cable tail The INT RJ5 or INT RJ10 define a...

Page 5: ...be tightly closed when operating Open only the covers pointed out in this installation manual Other covers should be open only by the manufacturer For security reasons install the unit out of the rea...

Page 6: ...se T Time delay of at least 4 A or fuse of 10 A max Or equivalent resettable devices such as magnetothermal fuses These ratings include inrush current for startup or temporary overload It must be very...

Page 7: ...urity Siqura EX PD24 Installation manual 7 Installation instruction INT RJ INT SM INT MM The interfaces are located in the camera Refer to the camera s installation manual for more information Cable g...

Page 8: ...TKH Security Proposal RFP Name RFP Number TKH Security Siqura INT RJ INT SM Installation manual 8 INT SM5 INT SM10...

Page 9: ...TKH Security Proposal RFP Name RFP Number TKH Security Siqura INT RJ INT SM Installation manual 9 Our Brands 2020 TKH Security tkhsecurity com 2021 TKH Security B V Our Brands...

Reviews: