TKB TZ68-E Quick Start Download Page 4

Version (version 1)

All Switch (version 1)

Configuration (version 1)

Manufacturer Specific (version 1)

Technical Data

Power Supply

230V ~50-60 Hz

Attachable Loads

loads up to 3500 W

IP Rating

20

Explorer Frame Support Yes

SDK

4.54.00

Device Type

Slave with routing capabilities

Generic Device Class

Binary Switch

Specific Device Class

Binary Power Switch

Routing

Yes

FLiRS

No

Firmware Version

1.4

Explanation of Z-Wave specific terms

Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically 

Gateways, Remote Controls or battery operated wall controllers.

Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators 

and even remote controls.

Primary Controller — is the central organizer of the network. It must be a controller. There can be only one 

primary controller in a Z-Wave network.

Inclusion — is the process of bringing new Z-Wave devices into a network.

Exclusion — is the process of removing Z-Wave devices from the network.

Association — is a control relationship between a controlling device and a controlled device.

Wakeup Notification — is a special wireless message issued by a Z-Wave device to annonces that is is 

able to communicate.

Node Information Frame — is a special wireless message issued by a Z_Wave device to announce its 

capabilities and functions.

Disposal Guidelines

The product does not contain hazardous chemicals.

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 4 

Summary of Contents for TZ68-E

Page 1: ...odes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated remote controls R This results ...

Page 2: ...st re switching The product is permitted only for proper use as specified in the user manual Any kind of guarantee claim has to be forfeited if changes modifications or painting are undertaken The product must be checked for damages immediately after unpacking In the case of damages the product must not be operated in any case If a danger free operation of the equipment cannot be assured the volta...

Page 3: ...r inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features IMPORTANT Controllers may only allow to configure signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example to set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In ...

Page 4: ...s can be sensors actuators and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling devi...

Page 5: ...tion regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 5 ...

Reviews: