TKB Home TZ79 Quick Start Manual Download Page 2

-3-

-2-

Product size (mm)

Set the On/Off 
switch of the load 
attached to on

Z-Wave  Configuration

Watt Meter
Report period

KWH Meter
Report period

Threshold of Watt
for load caution
Threshold of KWH
for load caution

watt Meter Report Period:
   If the setting is configured for 1 hour (set value =720), the TZ79 will report its instant power consumption every 1 hour 

to Z-Wave Controller. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600

=45hr).

KWH Meter Report Period:

   If the setting is configured for 1hour (set value =6), the TZ79 will report its Accumulated Power Consumption (KW/h) 
every 1 hour to Z-Wave controller.  The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 
days (10min*32767/1440=227.55 days).

Threshold of Watt for Load Caution:

   In the above form, when the value is 3000, if relay1 load by below 3000 watt turned into more than 3000 watt, 
will immediately send the instantaneous load w value to Group 1. The maximum set scope is 3000 watt, minimum 
scale value of 10 watt, the default value is 3000 watt.

Threshold of KWH for Load Caution:

   In the above form, when the value of 10000, when the accumulation of relay1 consumed power more than 10000 KWH, 
will immediately send the accumulation of current consumed power to group1 . Maximum can set range t0 10000 KWH, 
minimum scale value is 1 KWH, the default value is 0,

 

0

 

not

 

have

 

load

 

caution.

Memory function:

   Stated in the above form, TZ79 by default value is 1, when the value is 0, TZ79 memory function not open; When 
the value is 1, open TZ79 memory function.

Change the state of indicatorlight:

   Stated in the above form, the default value is 1, when the value of TZ79 is 0, socket LED indicator will be on when 
the light status is " on "; When set to 1 , the socket LED indicator will be off when the light status is " on ".

No node ID

The Z-Wave Controller does not allocate
a node ID to the Switch.

1-second on, 1-second off

1. Have Z-Wave Controller entered inclusion 
    mode.

2. Pressing On/Off button three times within 
    1.5 seconds will enter inclusion mode.

1. Have Z-Wave Controller entered exclusion 
    mode.

2. Pressing On/Off button three times within 
    1.5 seconds will enter exclusion mode.

Node ID has been excluded.

1. Pressing On/Off button three times within 
    1.5 seconds will enter inclusion mode.

2. Within 5 second, press On/Off button again 
    for 1 seconds until LED is off.

3. ID is excluded

1. Have Z-Wave Controller entered association 
    mode.
    Or  Pressing On/Off button three times within 
    1.5 seconds will enter association mode

2. There are two groups for the switch
   Each group can associate max five devices.

Including a node ID allocated by Z-Wave controller means Add. Excluding a node ID allocated by 

     Z-Wave controller means remove.

 Failed or success in including/excluding the node ID can be viewed from the Z-Wave controller.

 Association:it can be associated by Z-Wave devices with association

 Use the"Reset" procedure only in the event that the network primary controller is missing or 

     otherwise inoperable

 The group identifier is "Group 1 ".

  Association group info report command class
  Profile:General lifeline (Profile MSB=0x00,Profile LSB=0x01)
  Association group name report command class
  Group 1 :lifeline

 

7

Edge or Pulse

 

mode 

or Edge-Toggle mode

1-3 

3

1:Edge mode
2:Pulse mode
3:Edge-togle mode

0

0-10000

The switch isn’t working 
and LED off

1.The switch is not  
    connected to the power
2. The switch is out of 

order

    

1. Check power 
     connections
2. Don't open up the 

switch and send it 
to repair.

     
     

The swich LED illuminating, but can 
not control the On/Off switch of the 
load attached

Check if the load plugged 
into the switch has its own 
On/Off switch

The switch LED illuminating,but  the 
controler can not control the  switch 

1. Not carry out association
2. Frequency interference

1. Carry out association 
2. Wait for a while to re-try

LED keep flashing, but cannot 
control

Overload occurs

Remove the load attached 
or check max.
load cannot exceed 
3010W

3300W