Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT:
Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 1: Change the state of indicator light
Size: 1 Byte, Default Value: 0
Setting
Description
0
On -> LED ON
1
Off -> LED ON
Parameter 2: Memory function
Size: 1 Byte, Default Value: 0
Setting
Description
0
Disable
1
Enable
Parameter 3: Watt Meter Report Period
If the setting configured for 1 hour (set value = 720), the TZ69 will report its instant power consumtion every 1 hour to Z-Wave Controller. The maximum interval to
report its instand power consumption is 45 hours.
Size: 2 Byte, Default Value: 720
Setting
Description
1 - 32767
Time in 5 second steps
Parameter 4: KWH Meter Report Period
If the setting configured for 1 hour (set value = 6), the TZ69 will report its accumulated power consumtion every 1 hour to Z-Wave Controller. The maximum interval
to report its instand power consumption is 227,55 Days.
Size: 2 Byte, Default Value: 6
Setting
Description
1 - 32767
Time in 10 minutes steps
Parameter 5: Threshold of Watt for Load Caution
In the above form, when the value is 3000, if Relay 1 load by below 3000 watt turned into more than 3000 watt, will immediately send the instantaneous load w
value to Group 1.
Size: 2 Byte, Default Value: 3000
Setting
Description
10 - 3000
Threshold Watt
Parameter 6: Thresold of KWH for Load Caution
In the above form, when the value is 10000, if Relay 1 load by below 3000 watt, when the accumulation of Relay 1 consumed power more than 10000 KWH, will
immediately send the accumulation of current consumed power to Group 1.
Size: 2 Byte, Default Value: 10000
Setting
Description
1 - 10000
Thresold in KWH