DESCRIPTION & PURPOSE

The LB2 is Listed to the updated DEDPV, Dryer Exhaust Duct Power Ventilator supplement to UL705 & CSA C22.2 #113-12. The 2015

IRC restricts the use of dryer booster fans to those tested to the DEDPV supplement. Incorporating dryer booster fans in clothes dryer
ducts has increased substantially with the placement of laundry rooms not adjacent to outside walls. Duct runs often exceed 25 equiva-
lent feet (each elbow equates to five additional feet of duct length) that many manufacturers set as a maximum duct length. The LB2
booster fan is rated for duct lengths up to 150 equivalent feet.

SPECIFICATIONS & COMPONENTS

INSTALLATION RESTRICTIONS 

This product has rotating parts, do not plug into power if duct is not connected on both ends of Dryer Duct Booster®.

The installation must comply with local electrical and mechanical, fuel gas, or building codes, and must be inspected and accepted by
local authorities having jurisdiction.

CAUTION:

DO NOT INSTALL IN AN EXHAUST DUCTWORK OF A CLOTHES DRYER WHOSE INSTRUCTIONS PROHIBIT THE

INSTALLATION OF A CLOTHES DRYER BOOSTER FAN.

ATTENTION:

NE PAS INSTALLER DANS LE CONDUIT D’ÉVACUATION

DE LA SÉCHEUSE SI LES INSTRUCTIONS INTERDISENT L’INSTALLATION D’UN VENTILATEUR AUXILIAIRE.

CAUTION:

DO NOT INSTALL IN AN EXHAUST DUCTWORK WHERE THE EQUIVALENT DUCT LENGTH IS LESS THAN OR

EQUAL TO 7.62 METERS (25 FT). 

ATTENTION:

NE PAS INSTALLER DANS UN CONDUIT D’ÉVACUATION MESURANT 7,62

MÈTRES (25 PI) DE LONGUEUR OU MOINS.

The Dryer Booster Fan must be accessible after the installation is completed.

This Dryer Booster Fan may not be used in conjunction with dryers designated as high output.

WARNING

- If a blinking or solid Red LED is displayed on the Notification Panel turn off clothes dryer and reference “Dryer Booster Fan

Notification Panel Status Lights” section of these instructions.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1) Your clothing dryer installation incorporates a dryer exhaust duct power ventilator (DEDPV) which may be in a different location than 

your dryer, such as in an attic, crawl space or basement.

TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com

READ OWNERS INSTRUCTIONS CARE-
FULLY PRIOR TO INSTALLATION. SAVE
THESE INSTRUCTIONS. 

IMPORTANTES POUR LA SÉCURITÉ.
CONSERVEZ CES INSTRUCTIONS.

DRYER DUCT BOOSTER® FAN 

MODEL LB2

MODEL LB2

Blower:

160 cfm

Motor:  

115 Volts ~ 60 Hz
0.80 amps maximum

Impeller:

Reverse inclined, particulate handling

Components: (1) LB2 wired fan assembly

(1) Notification Panel
(1) 16 gauge galvanized steel mounting bracket
(1) mounting hardware packet

©2015 TJERNLUND PRODUCTS, INC.  ALL RIGHTS RESERVED

P/N: 8504216

For Residential Capacity Clothes Dryers

UL705
CSA C22.2 #113-12

WARNING

!

14"

 10.5"

OUTLET

INLET

4"

 10"

6.25"

FIGURE 8061040    1/19/15

4"

Summary of Contents for DRYER DUCT BOOSTER LB2

Page 1: ...O 7 62 METERS 25 FT ATTENTION NE PAS INSTALLER DANS UN CONDUIT D ÉVACUATION MESURANT 7 62 MÈTRES 25 PI DE LONGUEUR OU MOINS The Dryer Booster Fan must be accessible after the installation is completed This Dryer Booster Fan may not be used in conjunction with dryers designated as high output WARNING If a blinking or solid Red LED is displayed on the Notification Panel turn off clothes dryer and re...

Page 2: ...nd 140 F 29 C and 60 C and ambient humidity does not exceed 85 relative humidity Do not install the LB2 in a position where dryer exhaust temperatures exceed 175 F 80 C at LB2 inlet LB2 thermal fuse is set at 186 196 F 86 91 C The dryer duct in which the LB2 is installed must terminate with a dryer vent hood with a damper MINIMUM AND MAXIMUM DRYER DUCT LENGTH IN EQUIVALENT FEET This product is int...

Page 3: ...between the Notification Panel and the Dryer Duct Booster is greater than the length of the cable splice a section of 3 conductor PVC sheathed 19 AWG or larger 105 degree C thermostat cable to the supplied cable Make sure the color coded leads remain consistent An NEC approved accessible junction box and cover must be used to contain the splice Splices shall be made mechanically secure and insulat...

Page 4: ...ply Power to the LB2 by plugging in the power cord or cycling the power circuit the LB2 is plugged into NOTE Within 45 seconds of the LB2 Dryer Booster being supplied power it will come on and run for up to 45 seconds This is a cali bration period and will only happen when the LB2 is first powered During this time the Red and Green LED s on the Notification Panel will both flash quickly in an alte...

Page 5: ...ification Panel has been installed Wired cor rectly If the dryer is operating and there is no Green LED on the Notification Panel stop the dryer immediately and have the vent system inspected by someone qualified to do so Contact Tjernlund at 1 800 255 4208 with further questions See LB2 Troubleshooting for complete details LB2 ELECTRICAL BOX COMPONENTS LB2 ELECTRICAL BOX WIRING CONNECTIONS INSTAL...

Page 6: ...ION PANEL HAS NO LIGHTS The Notification Panel should always have a Green LED light on in at least a slow flash mode 1 2 second on 2 seconds off Do Not operate the dryer if there is no Green LED If no lights are illuminated on the Notification Panel for greater than 5 seconds there is an issue with the LB2 installation or the LB2 Confirm the LB2 has Power and that the Notification Panel has been i...

Page 7: ...RANTY Some states do not allow limitation on how long an implied warranty lasts so that limitation may not apply to you In addition some states do not allow the exclusion or limitation of incidental or consequential damages so that above limitation or exclusion may not apply to you This war ranty gives you specific legal rights and you may also have other rights which may vary from State to State ...

Reviews: