TJERNLUND PRODUCTS, INC.
1601 Ninth Street White Bear Lake, MN 55110-6794
Phone: 651.426.2993 800.255.4208 Fax: 651.426.9547
Visit our web site: www.tjernlund.com
Copyright © 2003 Tjernlund Products, Inc. P/N 8500590 Rev B 4/03
1. Inputs shown are
believed to be maximum
capacities for inducers
when mounted on pipe
sizes shown for ordinary
jobs where a moderate
amount of mechanical
induced draft is required.
2. Consideration is given
to typically higher static
pressure requirements for
larger installations, for the
type of fuel burned and
for the type of draft
control installed.
3. Some ratings may only
be valid for extremely
short vent lengths due to
excessive pressure loss; i.e.
the Model IL gas firing
with draft hood in 10"
pipe at 2,080,000 BTU/hr.
4. Where pressure require-
ments are unknown or
believed to be unusually
severe, ask for complete
performance curves or
consult factory.
5. Draft Inducers should
be installed in single wall
vent pipe in order to assure
proper performance.
Model Selection Table and Electrical Data
Model
DJ-3
D-3
I
IL
XL
HD
Pipe
Size
In.
3
4
5
6
5
6
7
8
8
9
10
12
9
10
12
14
16
18
16
18
20
24
20
24
69,000
105,000
111,000
100,000
270,000
356,000
360,000
320,000
900,000
1,110,000
1,250,000
1,030,000
1,460,000
2,080,000
1,920,000
1,840,000
900,000
650,000
4,000,000
3,900,000
2,800,000
1,500,000
5,300,000
3,500,000
Gas Firing
with Draft
Hood
270
0
F
Flue Gas
S.P.
.034
.042
.043
.041
.063
.073
.075
.068
.125
.135
.140
.128
.145
.170
.160
.159
.120
.099
.250
.240
.195
.150
.290
.220
CFM
48
72
72
68
190
246
259
217
590
765
850
710
1010
1370
1325
1270
620
450
2760
2650
1935
1035
3690
2415
72,000
109,000
104,000
34,000
330,000
377,000
330,000
222,000
1,200,000
1,330,000
1,260,000
710,000
1,970,000
2,460,000
2,230,000
1,470,000
650,000
440,000
4,000,000
3,250,000
2,100,000
1,100,000
5,200,000
3,750,000
Gas Firing
with Barometric
Draft Control
390
0
F
Flue Gas
S.P.
.047
.053
.052
.042
.085
.090
.085
.075
.143
.150
.145
.115
.175
.185
.182
.158
.113
.095
.260
.240
.175
.125
.270
.220
CFM
36
55
52
17
166
190
166
110
603
653
615
357
989
1240
1120
740
340
220
2010
1660
1079
527
2440
1660
58,000
92,000
74,000
25,000
295,000
300,000
230,000
123,000
1,100,000
1,100,000
840,000
400,000
1,700,000
1,900,000
1,500,000
825,000
350,000
200,000
3,300,000
2,100,000
1,200,000
503,000
3,600,000
2,900,000
Oil Firing
with Barometric
Draft Control
530
0
F
Flue Gas
S.P.
.048
.057
.052
.035
.092
.093
.080
.065
.147
.148
.136
.100
.180
.180
.170
.135
.095
.075
.230
.190
.150
.110
.240
.218
CFM
33
48
39
13
163
169
118
65
566
566
440
211
900
1010
789
453
184
106
1763
1103
626
266
1870
1550
Therm
Volts HZ RPM Watts Amps Prot.
115 60 1550 35 .43 Imp.
Prot.
115 60 1550 74 .96 Yes
115 60 1725 1/4 HP 5.4 Yes
115 60 1725 1/4 HP 5.4 Yes
115 60 1725 1/3 HP 6.0 Yes
115 12.6
208 60 1725 1 HP 6.2 Yes
230 6.3
208 6.3
230 60 1725 2 HP 6.4 No
460 3.2
Heater
BTU
Input
Heater
BTU
Input
Heater
BTU
Input
Electrical Specifications
IMPORTANT: Vents/Chimneys utilizing In-Line Draft Inducers must be vertically terminated above the roof line.
Do not use for side wall venting. Consult factory for proper side wall vent system options.
Tjernlund Products also offers:
Auto-Draft variable & fixed speed Inducers for roof top or side wall
venting. Reduce vent diameters by up to 50% and overcome convolut-
ed vent layouts. Fan speed is automatically regulated based on a user
set manifold/vent pressure, resulting in perfect draft and true energy
savings. Virtually unlimited capacities.
Combustion Air In-Forcers provide dedicated combustion air for safer,
more efficient equipment operation. Eliminates burner control lockouts
& oil odors associated with backdrafting. Ideal for "confined space" and
electric to oil or gas conversions. Residential and commercial fixed &
variable speed capacities up to 6000 CFM available.
Auto-Draft
®
Inducer
Combustion Air
In-Forcer
™
Note: Tjernlund
Products Inc. reserves
the right to make
changes to specifica-
tions without notice.
Distributed by: