• The AireShare™ may not be used to exhaust hazardous or explosive materials or vapors.
• The AireShare™ may not be installed in a ceiling.
• The AireShare™ may not be installed in an outside wall.
• The AireShare™ may not be installed in a wall rated as a “fire wall.”
• The AireShare™ may not be used to move air from one floor (story) to another floor.
• The AireShare™ may not be used to move moisture-laden air from sources such as
bathrooms and kitchens.
• The AireShare™ may not be used in a window.
WARNING:
To reduce the risk of fire, electrical shock and injury to persons, the
AireShare™ must be installed with the R2RP Diffuser that was provided with the R2RP.
Do not use this product without the R2RP Diffuser or with any Diffuser other than the
R2RP Diffuser.
WARNING:
To reduce the risk of fire or electrical shock, do not use this fan with any solid state
speed control devices.
Disrupt power at circuit breaker to outlets within the stud wall you will be working.
When sawing through sheetrock you must stop if you detect the saw blade coming in contact with any
wiring or plumbing. Investigate further to determine if it is possible to safely continue to use this wall cavity
space. Switch to another stud wall cavity if necessary.
BEFORE YOU START:
Determine the stud wall section that you want to use to mount the Blower and Diffuser. You
must
select a
stud wall section that contains an electrical outlet, (See Diagram A).
IMPORTANT: Wall studs must be
spaced a minimum of 16” o.c., (See Diagram B).
Mark inside edges of studs the Aireshare
TM
will be
installed between and verify there is at least 14” between the inside edges. Slide a stud finder down the wall
between the studs to verify the stud wall cavity is completely open, (See Diagram C).
TOOLS REQUIRED
Sheetrock Saw
Philips & Straight Screwdrivers
Level
Tape Measure Utility Knife or Scissors
INSTALLING DISCHARGE DIFFUSER
IMPORTANT:
Install Diffuser first if mounting the Blower down low and the Diffuser high so sheetrock from the
Diffuser cut out does not fall into wall cavity and damage Blower. Install the Blower first if mounting the Blower high
and Diffuser low so sheetrock from the Blower cut out does not fall into wall cavity and damage Diffuser.
NOTE:
Since electrical outlets are usually not up high, typical installations of the model R2RP will have the Diffuser
high and the Blower low, but there may be instances where it is desireable to have the Blower mounted
high and the Diffuser low to take air from the ceiling level.
1.The Diffuser may be mounted as close as 3" above the top of Blower cut out opening or as close as 3" to the ceiling.
2. Level and mark a line between studs for top of the Diffuser cut out, (See Diagram D)
3. Using a hand sheetrock saw carefully make a horizontal cut along the line. Cut the sheetrock completely until you
come in contact with the opposite stud.
NOTE:
If studs are spaced greater than 16” o.c., the horizontal cut line
should not exceed 14”, (See Diagram E).
DIAGRAM B
Wall studs must be
spaced a minimum
of 16” o.c.
IMPORTANT: Wall cavity
between studs must be com-
pletely open between Blower
intake and Diffuser
DIAGRAM D
DIAGRAM E
LEVEL AND MARK A
LINE BETWEEN STUDS
WHERE DIFFUSER IS
TO BE INSTALLED.
CAREFULLY MAKE A LEVEL
HORIZONTAL CUT IN SHEET-
ROCK BETWEEN STUDS NO
LONGER THAN 14”.
DIAGRAM C
Wall studs must
be spaced a
minimum
of 16” o.c.
BLOWER
OPENING
DIFFUSER
IMPORTANT:
Wall cavity
between studs
must be com-
pletely open
between
Blower intake
and Diffuser
Electrical box must
be installed inside
stud wall section
WALL STUD
OUTLET
AIRESHARE
AIRESHARE
WALL STUD
ELECTRICAL
WRONG
CORRECT
ELECTRICAL OUTLET SIDE OF THE WALL STUD.
THE AIRESHARE MUST BE LOCATED ON THE
CORRECT
WRONG
AIRESHARE
AIRESHARE
WALL STUD
DIAGRAM A