• The AireShare™ may not be used to exhaust hazardous or explosive materials or vapors.

•  The AireShare™ may not be installed in a ceiling.

•  The AireShare™ may not be installed in an outside wall.

•  The AireShare™ may not be installed in a wall rated as a “fire wall.”

•  The AireShare™ may not be used to move air from one floor (story) to another floor.

•  The AireShare™ may not be used to move moisture-laden air from sources such as 

bathrooms and kitchens.

•  The AireShare™ may not be used in a window.

WARNING:

To reduce the risk of fire, electrical shock and injury to persons, the 

AireShare™ must be installed with the R2RP Diffuser that was provided with the R2RP. 
Do not use this product without the R2RP Diffuser or with any Diffuser other than the 
R2RP Diffuser.

WARNING:

To reduce the risk of fire or electrical shock, do not use this fan with any solid state 

speed control devices.

Disrupt power at circuit breaker to outlets within the stud wall you will be working. 

When sawing through sheetrock you must stop if you detect the saw blade coming in contact with any
wiring or plumbing. Investigate further to determine if it is possible to safely continue to use this wall cavity
space. Switch to another stud wall cavity if necessary.

BEFORE YOU START:

Determine the stud wall section that you want to use to mount the Blower and Diffuser. You 

must

select a

stud wall section that contains an electrical outlet, (See Diagram A). 

IMPORTANT: Wall studs must be

spaced a minimum of 16” o.c., (See Diagram B). 

Mark inside edges of studs the Aireshare

TM

will be

installed between and verify there is at least 14” between the inside edges. Slide a stud finder down the wall
between the studs to verify the stud wall cavity is completely open, (See Diagram C).

TOOLS REQUIRED

Sheetrock Saw 

Philips & Straight Screwdrivers    

Level   

Tape Measure       Utility Knife or Scissors

INSTALLING DISCHARGE DIFFUSER

IMPORTANT:

Install Diffuser first if mounting the Blower down low and the Diffuser high so sheetrock from the

Diffuser cut out does not fall into wall cavity and damage Blower. Install the Blower first if mounting the Blower high
and Diffuser low so sheetrock from the Blower cut out does not fall into wall cavity and damage Diffuser.

NOTE:

Since electrical outlets are usually not up high, typical installations of the model R2RP will have the Diffuser 
high and the Blower low, but there may be instances where it is desireable to have the Blower mounted 
high and the Diffuser low to take air from the ceiling level. 

1.The Diffuser may be mounted as close as 3" above the top of Blower cut out opening or as close as 3" to the ceiling. 

2. Level and mark a line between studs for top of the Diffuser cut out, (See Diagram D)  

3. Using a hand sheetrock saw carefully make a horizontal cut along the line. Cut the sheetrock completely until you 

come in contact with the opposite stud. 

NOTE:

If studs are spaced greater than 16” o.c., the horizontal cut line 

should not exceed 14”, (See Diagram E).

DIAGRAM B

Wall studs must be

spaced a minimum 

of 16” o.c.

IMPORTANT: Wall cavity
between studs must be com-
pletely open between Blower
intake and Diffuser

DIAGRAM D

DIAGRAM E

LEVEL AND MARK A
LINE BETWEEN STUDS
WHERE DIFFUSER IS
TO BE INSTALLED.

CAREFULLY MAKE A LEVEL
HORIZONTAL CUT IN SHEET-
ROCK BETWEEN STUDS NO
LONGER THAN 14”.

DIAGRAM C

Wall studs must

be spaced a

minimum 

of 16” o.c.

BLOWER 

OPENING

DIFFUSER

IMPORTANT:
Wall cavity
between studs
must be com-
pletely open
between
Blower intake
and Diffuser

Electrical box must

be installed inside

stud wall section

WALL STUD

OUTLET

AIRESHARE

AIRESHARE

WALL STUD

ELECTRICAL

WRONG

CORRECT

ELECTRICAL OUTLET SIDE OF THE WALL STUD.

THE AIRESHARE MUST BE LOCATED ON THE

CORRECT

WRONG

AIRESHARE

AIRESHARE

WALL STUD

DIAGRAM A