(950-8302) CRAWL SPACE VENTILATOR T-STAT REPLACEMENT KIT

Disconnect power or unplug 115 VAC power cord before 
servicing the Crawl Space Ventilator.

1. Remove Crawl Space Ventilator from wall. 

IMPORTANT:

Note set-

ting of dehumidistat (if equipped) so it can be reset when finished.
Remove BLACK T-stat leads.

2. Use caution and drill out (2) T-stat rivets from exterior mounting 

plate with a 5/32” drill bit, (See Diagram A).

3. Insert (2) 6-32 x 1/4” studs through mounting plate and T-stat and 

tighten keps nuts. Replace BLACK T-stat leads.

4. Reinstall Crawl Space Ventilator in opening.

5. Reestablish 115 VAC power and cycle Crawl Space Ventilator “on” to verify proper operation. Reset dehumidistat (if equipped). 

NOTE:

If outside temperature is below 50

o

F, T-stat may not allow Ventilator to turn on.

Rev. 10/06

Copyright © 2006, Tjernlund Products, Inc. All rights reserved.

P/N 8504132

TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com

EXTERIOR VIEW

Model V1 Shown

Drill out (2) T-stat
rivets on exterior
mounting plate with
5/32” drill bit.

DIAGRAM A