REV. 2, 11/96
© 1996 TJERNLUND PRODUCTS, INC.
P/N 8504051
GAS WIRING TO ANY APPLIANCE EQUIPPED WITH 24V CONTROLS
NO POST-PURGE RELAY/TIMER ON DRAFT INDUCER
COMPONENTS NEEDED:
(1) DRAFT INDUCER
(1) PS1505 FAN PROVER
(1) 24/115V RELAY
USE 950-1040 FOR MODELS DJ3 & D3
USE 950-1016 FOR MODELS I, IL, XL
DRAFT INDUCER CONNECTED TO OIL BURNER WITH R8184G CONTROLS
(DRAFT INDUCER MOTOR LESS THAN 4.4 AMPS) INCLUDES MODELS UP TO THE D3
COMPONENTS NEEDED:
(1) DRAFT INDUCER
(1) PS1505 FAN PROVER
(1) 950-1067 RELAY/TIMER
MAXIMUM AMP LOAD IS
4.4 AMPS
USE DIAGRAM BELOW IF
DRAFT INDUCER MOTOR
IS GREATER THAN 4.4 AMPS
DRAFT INDUCER CONNECTED TO OIL BURNER WITH R8184G CONTROLS
(DRAFT INDUCER MOTOR GREATER THAN 4.4 AMPS) INCLUDES THE MODELS I, IL, XL
COMPONENTS NEEDED:
(1) DRAFT INDUCER
(1) PS1505 FAN PROVER
(1) 950-1067 RELAY/TIMER
MAXIMUM AMP LOAD IS 4.4 AMPS
(1) HONEYWELL R4222B1082 RELAY
OR EQUIVALENT
(INSTALLER SUPPLIED)