22
Cleaning
The CME1 must be periodically cleaned internally. The maximum time between
cleaning will depend on the local environment, however every 3 – 4 years is recom-
mended.
WARNING: The unit uses a 230V ~ supply and contains rotating mechanical parts.
Isolate the unit from mains power supply and allow suffi
cient time for all moving
parts to stop before undergoing any Servicing or Maintenance.
To gain access to the interior of the unit for cleaning
Unscrew the 3 retaining screws that
hold on the COVER and remove.
•
Maintenance
Remove the 4 SCROLL retaining
screws..
•
3
3
1
1
2
2
4
4
Online Version