OPERATION (CONT’D)

Starting up Sampling Regime on SD card

•  Use CFCread version 4.4j or later
•  Click on Sampling - opens Wizard

 

Choose total run time, click “Next”

 

Choose time of day to sample, click “Next”

 

If required, provide Latitude, Longitude and Time 

Zone, click “Next”

 

-

Latitude in degrees and decimals (po sitive 

latitude reading is northern hemisphere)

 

-

Longitude in degrees and decimals (positive 

longtitude reading is east of England)

 

-

Time Zone in hours ahead of GMT (may use 

decimals)

 

Choose battery capacity, click “Finish”

 

Select a folder for storing a log file (you can store it 

anywhere)

 

OK

•  Be conservative in setting battery capacity

 

If battery does not achieve rated capacity, monitor-

ing will stop earlier than expected

Starting Roost Logger

•  Insert batteries

 

Make sure batteries make contact at each end

 

Heartbeat LED (red) will flash twice per second 

•  Insert SD card

 

SD LED flashes rapidly three times then off

 

Heartbeat LED also off

•  Close lid
•  Check operation with magnet

Deployment

•  Point front surface of microphone towards bats
•  Avoid obstructions in front of microphone
•  Ensure Roost Logger is securely positioned in a safe place 

away from any potential damage by falling objects

•  Avoid directing towards obvious noise sources such as 

cascading or dripping water 

•  Avoid likely habitat of ultrasonic insects
•  Where possible, protect from direct impacts of weather
•  Use horizontal microphone alignment when feasible
•  Elevate detector above ground if feasible

www.titley-scientific.com 

|

  2

Summary of Contents for AnaBat Roost Logger

Page 1: ...eries up to 6 months at night only with 50 duty cycle or 6 weeks continuously Calibrated all Roost Loggers leave factory set to same sensitivity OPERATION Power Supply 4 D cells Alkaline for low cost Lithium if available for extended use at low temperatures below freezing point Key points Check Use by dates Check voltage of each cell and note uniformity Cells should be at least 1 5 Volts each Do n...

Page 2: ...ne in hours ahead of GMT may use decimals Choose battery capacity click Finish Select a folder for storing a log file you can store it anywhere OK Be conservative in setting battery capacity If battery does not achieve rated capacity monitor ing will stop earlier than expected Starting Roost Logger Insert batteries Make sure batteries make contact at each end Heartbeat LED red will flash twice per...

Page 3: ...lightly may help Even one flash of LED indicates the unit is powered ON Practice using magnet before field deployment Practice the steps until you feel confident you can get an indication Avoid false negatives suggesting dead batteries Understanding Heartbeat LED OFF in normal operation to save power and avoid flashing which could draw unwanted attention to the Roost Logger Turned ON using magnet ...

Page 4: ...grading Firmware Copy Roost Logger Firmware Upgrade Pack to PC hard drive and extract Open Device Manager Power up Roost Logger with no SD card installed Heartbeat LED flashes twice per second Plug in USB cable from PC to Roost Logger Heartbeat LED off SD LED will be flashing fast Place Roost Logger in Update Mode Hold down SD Remove Button SD LED will turn on continuously Briefly press the Reset ...

Reviews: