Titanium 88660 Instruction Manual Download Page 6

Fig. 6

Fig. 7

5

4

2

6

3

8

7

1

1

6

EN

• 

 

Press the

 pulse mode

 button on the top of the laser level 

to enter into pulse mode. The 

pulse mode indicator

 LED 

will light up.

• 

 

Switch the detector on by pressing the 

power

 button. 

The speaker will beep indicating the detector is 

operating.  

• 

 

Move the detector into the path of the laser beam. 

• 

 

Hold the detector upright for horizontal beams (Fig. 6). 

Rotate the detector 90° for vertical beams (Fig. 7). 

• 

 

The LED direction indicators will indicate the position of 

the laser beam. The centre LED will indicate alignment 

with the beam.

USING THE DETECTOR 

MOUNTING TO A TRIPOD

              

The 

Titanium TML-D3H (89110)

 detector 

and clamp can be purchased from your 

nearest Titanium dealer.

             

  A tripod can be purchased from your nearest 

measurement tool dealer. The below instructions are 

generic only and set-up methods may vary between 

models. Refer to the documentation from the tripod 

manufacturer for details. 

i

i

DETECTOR OVERVIEW

DETECTOR OPERATION

 Bubble vial
2  LED direction indicators
3  Power button
4  Power LED indicator
 Sound on / off button
 Sound LED indicator
 Laser sensor
8  Speaker

NOT INCLUDED

NOT INCLUDED

!

                 WARNING! Attaching the laser to a  

tripod without the correct thread size  

may cause damage.

•   Extend the tripod legs to the required height and 

ensure the legs are spread wide enough so that 

the tripod platform is stable. Secure the legs in 

place (refer to the documentation from the tripod 

manufacturer for details). 

•   Place the laser level onto the tripod and mount via 

the male thread (5/8” or 1/4”) into the base until firm. 

Do not over tighten as this may cause damage to 

the laser level or tripod. 

 

NOTE: adjustment methods will vary on tripod models. 

Always ensure that any locking levers are unlocked 

before making adjustments and returned to the locked 

position when the adjustment is complete. 

•   If using an elevating tripod with a measuring scale on the 

centre column, the height can be adjusted as required.

Summary of Contents for 88660

Page 1: ...Product Code 88660 REVISION 2020 1 0 Instruction Manual TML 3DRS Standard Kit R E D M U LT I L I N E L A S E R...

Page 2: ...2...

Page 3: ...am Serious eye injury could result Do not position the tool near a reflective surface which may reflect the laser beam toward anyone s eyes Serious eye injury could result Do not use optical tools to...

Page 4: ...the li ion battery onto the charging adaptor Fig 1 Fig 2 Progress will be shown by the power indicator display on the charging adaptor as below Red flashing Charger and battery are not connected Red c...

Page 5: ...n the laser level on slide the power locking switch to the unlocked position Self levelling will commence and the horizontal beam will activate Fig 4 Press the line mode button on the control panel to...

Page 6: ...ntation from the tripod manufacturer for details i i DETECTOR OVERVIEW DETECTOR OPERATION 1 Bubble vial 2 LED direction indicators 3 Power button 4 Power LED indicator 5 Sound on off button 6 Sound LE...

Page 7: ...tear 4 All products have a standard warranty period you do not have to register your products to obtain the standard warranty period 5 To claim under this warranty the date of purchase of the tool mus...

Page 8: ...rror Cause Solution Laser does not turn on Check the batteries They may be in the wrong way or need replacing Check the battery compartment for signs of damage and ensure that the compartment is clean...

Page 9: ...9 EN NOTES...

Page 10: ...10 NOTES EN...

Page 11: ...11 EN NOTES...

Page 12: ...2020 Titanium Laser Tools...

Reviews: