background image

MINI CIRCULAR SAW 500W TTB689CSW

12

potential risks of injury and damage remain. The following dangers can arise in connection 

with the structure and design of this product:

1.  Health defects resulting from vibration emission if the product is being used over long 

periods of time or not adequately managed and properly maintained.

2.  Injuries and damage to property due to broken application tools or the sudden impact of 

hidden objects during use.

3.  Danger of injury and property damage caused by lying objects.

WARNING!

This product produces an electromagnetic ield during operation! This ield may under 

some circumstances interfere with active or passive medical implants! To reduce the risk of 

serious or fatal injury, we recommend persons with medical implants to consult their doctor 

and the medical implant manufacturer before operating this product!

Health Surveillance

All employees should be part of an employer’s health surveillance scheme to help identity 

any vibration related diseases at an early stage, prevent disease progression and help 

employees stay in work.

Double insulation

 

The tool is double insulated. This means that all the external metal parts are electrically 

insulated from the mains power supply. This is done by placing insulation barriers between 

the electrical and mechanical components making it unnecessary for the tool to be earthed.

Important note

Be sure the supply is the same as the voltage given on the rating plate. Remove the mains 

plug before carrying out any adjustment or servicing.

Summary of Contents for TTB689CSW

Page 1: ...MINI CIRCULAR SAW 500W TTB689CSW SAFETY AND OPERATING MANUAL Original Instructions V5 0 25 20 15 10 5 0...

Page 2: ...t your retailer GUARANTEE This product carries a guarantee of 2 years If your product develops a fault within this period you should in the irst instance contact the retailer where the item was purcha...

Page 3: ...tors ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded c Do not expose power tools to rain or wet conditions Water entering a power tool will i...

Page 4: ...not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired c Disconnect the plug from the power source and or the battery pack from the power to...

Page 5: ...ersus round of arbour holes Blades that do not match the mounting hardware of the saw will run eccentrically causing loss of control h Never use damaged or incorrect blade washers or bolt The blade wa...

Page 6: ...inding h Do not restart the cutting operation in the workpiece Let the wheel reach full speed and carefully re enter the cut The wheel may bind walk up or kickback if the power tool is restarted in th...

Page 7: ...thus reducing the possibility of wheel breakage f Do not use worn down reinforced wheels from larger power tools Wheels intended for a larger power tool are not suitable for the higher speed of a smal...

Page 8: ...dered metal may cause electrical hazards q Do not operate the power tool near lammable materials Sparks could ignite these materials r Do not use accessories that require liquid coolants Using water o...

Page 9: ...s within this because of the dust that they breathe silica dust is not just a nuisance it is a real risk to your lungs Silica is a natural mineral present in large amounts in things like sand sandston...

Page 10: ...ebsite http www hse gov uk construction or http www hse gov uk pubns cis69 pdf WARNING Some dust created by power sanding sawing grinding drilling and other construction activities contains Chemicals...

Page 11: ...ive requires power tool manufacturers and suppliers to provide indicative vibration test results to enable users to make informed decisions as to the period of time a power tool can be used safely on...

Page 12: ...as wear personal protective equipment Take the following points into account to minimize the vibration and noise exposure risks 1 Only use the product as intended by its design and these instructions...

Page 13: ...l implants To reduce the risk of serious or fatal injury we recommend persons with medical implants to consult their doctor and the medical implant manufacturer before operating this product Health Su...

Page 14: ...otection Wear respiratory protection Wear safety gloves Warning Double insulation Class II Laser radiation Do not stare into beam Conforms to all relevant safety standards Waste electrical products sh...

Page 15: ...7 11 23 8 3 12 14 5 25 20 15 10 5 0 85mm x 10mm x 1 6mm x 80T max 7000 min Titan Power Tools UK Ltd BA22 8RT Titan Power Tools UK Ltd BA22 8RT 19 85mm x 10mm x 1 6mm x 20T max 7000 min Titan Power Too...

Page 16: ...th scale 7 Hex nut 8 Saw blade clamp lange 9 Cutting depth guide rail 10 Saw blade safety guard 11 TCT blade 12 Laser 13 Laser battery compartment 14 Laser On Off switch 15 Base plate 16 Spindle lock...

Page 17: ...2 Wavelength 650nm Output power 1mW Energy source CR2032 x 1 NOISE DATA Sound pressure level LpA 90 dB A K 3dB A Sound power level LwA 101 dB A K 3dB A Wear ear protection when sound pressure is over...

Page 18: ...before plugging in the power cord 2 Choose a corresponding saw blade and check its condition and sharpness 3 Make sure you keep the ventilation slots clear when holding the tool 4 Pull the On Off swi...

Page 19: ...it with the mounting lange Do not use reducers or adapters The direction of rotation arrow on blade and machine see direction of rotation arrow on the machine enclo sure should be same To change the b...

Page 20: ...y cause serious injury 5 LASER GUIDE Fig 9 Make the line of cut on the workpiece irst Adjust the depth of cut as required and rest the front edge of the base on the workpiece Only turn the laser on wh...

Page 21: ...e dust related haz ards To prevent personal injuries make sure to connect a suitable vacuum cleaner to the dust extraction port by means of the dust collecting system adaptor To connect a dust collect...

Page 22: ...t button to continue TERMS OF USE When all precautions have been taken and the previ ous operations were done you can start working The stress on the machine should not be such that the speed is reduc...

Page 23: ...only be removed or replaced by a qualiied electrician STORING Store the machine operating instructions and where necessary the accessories in the original packaging In this way you will always have a...

Page 24: ...as follows The wire which is coloured blue must be con nected to the terminal which is marked with N The wire which is coloured brown must be connected to the terminal which is marked with L Warning N...

Page 25: ...11 65 EU Restrictions of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment 2012 19 EU Waste Electrical and Electronic Equipment WEEE Standards and technical speciications...

Reviews: