It means that internal inside thermal
sensor is short or open circuit.
Please contact your local distributor
if the internal thermal sensor is abnormal,
Over temperature protection.
The charger will automatically restart when internal
temperature reaches operational temperature range.
Flash 5
times
Description
Solution
Indicator
Light
Red
Light
It means that the charger isn’t
correctly connected to battery
or the DC fuse is burned.
Flash 2
times
Please contact your local distributor
if the red indicator light still flashes twice
after disconnecting the cord.
Charger output voltage is not
compatible with the battery.
Please check that the correct
charging voltage is selected.
Flash 3
times
(C) Explanation of Usage
:
1. When it is charging , it does not effect your configuration if you press the voltage selecting
key. Please disconnect the battery if you wish to select a different voltage.
2. When float green light is flashing , it means that the battery is full.
3. Please disconnect the AC cord and DC output cord if you wish to end charging.
(b) Unusual Indicating light of charger instructed as below
:
(B) Status display light of charger instructed as below
:
(a) Usual Indicating light of charger instructed as below
:
It is in floating status , battery is full.
It is in floating status, battery is full with floating current of < 0.5 A.
It is in Absorption C.V. (Constant Voltage) charging status.
Slow Flashing frequency
Yellow
Light
Fast Flashing frequency
Green
Light
Indicator light
Super Fast Flashing frequency
Slow Flashing frequency
Fast Flashing frequency
Descreption
It is in Soft Start status, current is charging slowly.
Lighting Up
It is in Absorption C.C.(Constant Current) charging status.
It is in Float C.C.( Constant Current ) charging status