FIRE OR EXPLOSION HAZARD

Static electricity is created by the high velocity of fluid through the pump, hose and tip.  If every part of the spray element

is not properly grounded, sparking may occur and the system may become hazardous.  Sparking may also occur when

plugging in or unplugging a power supply cord, or starting a gas engine.  Sparks can ignite fumes from solvents or the

fluids being sprayed.  Always plug the sprayer into an outlet at least 25' (7,5) away from the spray area.

WARNING: Always flush the unit into a separate metal container with the spray tip removed and the gun held

firmly against the side of the container to assure proper grounding and prevent static discharge which could

cause serious bodily injury.

If you experience any static sparking or slight shock while using this equipment, stop spraying immediately.  Check the

entire system for proper grounding.  Do not use the system again until the problem has been corrected.

ELECTRIC MOTOR

The electric motors used by TITAN are not explosion proof.  Therefore, it is essential to keep the working area

around the pump well ventilated.  Additionally, the pump itself should be a minimum of 25' (7,5) from the spray

area.   

WARNING: Always keep pump outside of any enclosed spray area.  Never clean the exterior of the pump with

any flammable solvents. 

GAS ENGINE (Where Applicable)

Always keep pump outside of any enclosed spray area.  Keep area around pump well ventilated.  Keep all sol-

vents away from engine exhaust.  (Never fill the fuel tank while the engine is running or hot.  Fuel spilled on a

hot surface can ignite and cause a fire.)  Always attach ground wire located on rear of engine to a grounded

object, i.e. water pipe.  NOTE: Refer to engine owner's manual for additional safety and service information.

FLUID SECTION—SOLVENTS

Halogenated Hydrocarbon solvents can cause an explosion when used with aluminum or galvanized components in a

closed (pressurizable) fluid system (pumps, heaters, filters, valves, spray guns, tanks, etc.).  The explosion could cause

serious injury, death and/or substantial property damage.  Cleaning agents, coatings, paints, etc. may contain

Halogenated Hydrocarbon solvents.  Titan Tool Inc. spray equipment includes aluminum or galvanized components

and will be affected by Halogenated Hydrocarbon solvents.  

DO NOT USE HALOGENATED HYDROCARBONS IN

TITAN EQUIPMENT.

EXPLANATION OF THE HAZARD

There are three key elements to the Halogenated Hydrocarbon (HHC) solvent hazard.  These elements are:

1. The presence of HHC solvents.

2. Aluminum or galvanized parts.

3. Equipment capable of withstanding pressure.

When all three elements are present, the result can be an extremely violent explosion.  The reaction can be sustained

with very little aluminum or galvanized metal:  any amount of aluminum is too much.  The reaction is unpredictable.

Prior use of an HHC solvent without incident (corrosion or explosion) does NOT mean that such use is safe.

PELIGRO DE INCENDIO O EXPLOSIÓN

La alta velocidad del líquido a través de la bomba, manguera y la boquilla produce electricidad estática.  Si algún com-

ponente del equipo de rociadura no está conectado a tierra correctamente pueden producirse chispas y el sistema se

vuelve peligroso.  También pueden producirse chispas al enchufar o desenchufar cables eléctricos o al poner en fun-

cionamiento un motor a gasolina.  Las chispas pueden encender los vapores provenientes de los solventes o de los

líquidos rociados.  Siempre conecte el rociador a un enchufe ubicado a no menos de 7,5m de distancia de la zona de

rociadura.

ADVERTENCIA: Lavar siempre la unidad en un recipiente metálico separado, habiendo quitado la boca del roci-

ador y teniendo la pistola firmemente contra el lado del recipiente para asegurar una puesta a tierra correcta y

evitar la descarga estática que podría causar lesión corporal grave.

Si ocurren chispas de electricidad estática o si sufre un shock eléctrico ligero mientras usa el equipo, deje de rociar de

immediato.  Verifique que el sistema en su totalidad esté conectado a tierra correctamente.  No vuelva a usar el sistema

hasta que el problema haya sido resuelto.

MOTOR ELÉCTRICO:

Los motores eléctricos utilizados por TITAN no son a prueba de explosión.  Por lo tanto, es esencial mantener

el área de trabajo alrededor de la bomba bien ventilada.  Además, la bomba misma debe estar a una distancia

minima de 7,5m del area de rociadura.

ADVERTENCIA: Mantener siempre la bomba afuera de cualquier área de rociadura cerrada.  Nunca limpie el

exterior de la bomba con solventes inflamables.

Summary of Contents for 1100XC 781-104-CE

Page 1: ...manual contains important warnings and instructions Please read and retain for reference Model Numbers 110V Low Rider Bare 702 2000 110V Low Rider Complete 702 2001 110V High Rider Bare 702 2002 110V High Rider Complete 702 2003 110V Skid Bare 702 2004 230V Low Rider Bare 702 102 CE 230V Low Rider Complete 702 104 CE NOTE This manual contains important warnings and instructions Please read and ret...

Page 2: ...n Assembly 16 17 Replacement Labels 17 Motor Assembly 18 19 Armature Replacement 18 Motor Housing Replacement 19 Gear Box Assembly 20 Gear Replacement 21 ON OFF Switch 21 Power Supply Cord 21 Motor Brush Replacement 21 Filter Block Assembly 22 Pressure Switch Replacement 23 Replacement of the Bypass Valve 23 Filter Replacement 23 Fluid Section Assembly 24 Siphon Assembly 24 Pump Repair 25 Low Ride...

Page 3: ... loosen the connector from the wire 3 Test your repair before regular operation of the sprayer to be sure that the problem is corrected If the sprayer does not operate properly review the repair procedure to determine if everything was done correctly Refer to the Troubleshooting Charts to help identify other possible problems 4 Make certain that the service area is well ventilated in case solvents...

Page 4: ...ny name This information will be needed to validate your warranty Maintenance Schedule Check Piston Seal Lubricant Level WEEKLY Epic 440HP Electric Motor Models Check motor brushes every 200 hours Date Date Date Date Date Date Date Date Date Date Service Record Service Performed Date Service Center Cost of Repair Months in Service Service Performed Date Service Center Cost of Repair Months in Serv...

Page 5: ... the spray area If these instructions are not followed there is the possibility of fire or explosion with certain materials ALWAYS follow the coating or solvent manufacturer s safety precautions and warnings Never spray flammable material near open flames pilot lights or any source of ignition 9 ALWAYS wear spray masks and protective eyewear while spraying Additional personal protective equipment ...

Page 6: ...operación de rociadura Si no se observan estas instrucciones existe el riesgo de incendio o explosión con ciertos materiales SIEMPRE observe las precauciones y advertencias de los fabricantes sobre revestimientos y solventes Nunca rocíe material inflamable cerca de llamas expuestas llamas piloto o cualquier fuente de ignición 9 SIEMPRE use máscaras apropiadas y anteojos de protección durante la op...

Page 7: ...n récipient en métal lors du rinçage du système après en avoir ôté la buse Ne vaporisez JAMAIS de substances inflammables à proximité de flammes nues lampes témoin ni d aucune source d allumage Rangez à l intérieur 8 Le moteur électrique de cet appareil n est pas protégé contre les explosions Il est donc essentiel d assurer une bonne ventilation de la zone de travail et des alentours de la pompe I...

Page 8: ...arbon solvents Titan Tool Inc spray equipment includes aluminum or galvanized components and will be affected by Halogenated Hydrocarbon solvents DO NOT USE HALOGENATED HYDROCARBONS IN TITAN EQUIPMENT EXPLANATION OF THE HAZARD There are three key elements to the Halogenated Hydrocarbon HHC solvent hazard These elements are 1 The presence of HHC solvents 2 Aluminum or galvanized parts 3 Equipment c...

Page 9: ...telles étincelles sont suscepti bles d enflammer les vapeurs des solvants ou les liquides pulvérisés Veillez donc toujours à brancher le pulvérisateur dans une prise située à au moins 7 5m du pulvérisateur et de la zone de travail MISE EN GARDE Toujours rincer l appareil dans un récipient métallique distinct après avoir enlevé le bec de pul vérisation et en tenant fermement le pistolet contre le c...

Page 10: ... coating contains Halogenated Hydrocarbon Solvents SOLVENTES HALOGENADOS DEFINICION Cualquier solvente a base de hidrocarburos que contenga cualquiera de estos elementos EJEMPLOS lista parcial Consulte la información suministrada por su proveedor de materiales para determinar si un solvente o revestimiento contiene solventes de Hidrocarburos Halogenados SOLVANTS HALOGÉNÉS DÉFINITION Tout solvant à...

Page 11: ...aining mineral spirits E Open the fuel shut off lever by pushing it in the direction of the arrow F Move the throttle lever away from fuel tank G Close the engine choke lever located beneath the air cleaner H Turn the engine switch on Turn pressure relief prime valve down to prime position I Pull the starter rope Holding the frame with one hand pull the rope rapidly and firmly Continue to hold the...

Page 12: ...n by 50 Too Thick Offspray Arcing Gun at angle start stroke release trigger pull trigger end stroke For corners and edges split the center of the spray pattern on the corner or edge and spray vertically so that both adjoining sections receive approximately even amounts of paint If conditions are windy angle the spray pattern into the wind to minimize drifting Work from ground to roof Do not attemp...

Page 13: ...r run itself dry 10 Check filter on pump and gun Clean or replace 11 Remove spray tip from solvent clean with a soft bristle brush and store in a dry place Cause 1 Inadequate fluid delivery 2 Fluid not atomizing 3 Insufficient velocity 4 Material too cohesive 5 Tip worn past pump capacity 1 Worn tip 2 Tip may be chipped 1 Plugged worn or chipped tip 1 Leak in suction tube 2 Not enough hose 3 Tip t...

Page 14: ...ficient material flow Pump will not maintain pressure Not enough pressure Excessive surge at spray gun Paint leaks into oil cup Cause 1 Unit unplugged or circuit fuse blown 2 Pressure setting too low 3 Brushes on motor are worn 4 Electric motor burned out 5 Switch defective 6 Fuse in pump blown 1 Engine switch not on 2 Engine oil level low 3 Out of gas 4 Spark plug cable disconnected or bad plug 1...

Page 15: ...the ON OFF Switch 49 3 Remove the rubber boot and plate 47 48 with a wrench 4 Remove the ON OFF Switch 49 5 Install a new Switch and reattach plate and rubber boot Tighten securely 6 Reconnect the four wires to the new ON OFF Switch 7 Reinstall Pressure Control Board and screws with warning label facing out Power Supply Cord Replacement WARNING Before proceeding follow the Pressure Relief Procedur...

Page 16: ...16 Titan Tool Inc All rights reserved Main Assembly Figure 2 ...

Page 17: ...ll rights reserved 17 Replacement Labels Part Description Quantity 700 1017 Front Cover Label 1 313 175 Warning Attention Label In French 1 313 1436 Wraparound Label 1 NOTE Siphon down tube for use with High Rider only ...

Page 18: ...o reduce the risk of an injection injury injury from moving parts or electric shock Always unplug the sprayer before servicing 1 Remove Rear Cover 131 by taking out screws 130 2 Remove Snap Ring 133 3 Remove Fan 135 4 Remove Snap Ring 133 5 Remove Rear Motor Housing 136 by removing screws 132 6 Remove Motor Brushes Follow Brush replacement procedure located on page 21 7 Remove Armature by gently r...

Page 19: ...the risk of an injection injury injury from moving parts or electric shock Always unplug the sprayer before servicing 1 Follow steps 1 through 6 in Armature Replacement 2 Remove Pressure Control Board and screws located on Page 20 3 Disconnect black wire from Post 2 of Motor Starter 54 4 Disconnect black wire from Motor to white wire from Power Cord 5 Remove outer Motor Housing 140 6 Loosen set sc...

Page 20: ...39 700 680 Thrust Washer 1 40 702 076 Pump Housing Assembly 1 41 700 681 Screw 4 42 700 653 Screw 1 43 700 791 Safety Plate 1 Gear Box Assembly Item Part Description Quantity 44 700 1017 Front Plate 1 45 765 063 Cord Grip Assembly 1 46 765 054 Power Cord 1 761 725 Power Cord 230V units 47 700 645 Rubber Boot 1 48 700 775 On Off Plate 1 770 593 On Off Plate 230V units 49 700 646 Toggle Switch 1 765...

Page 21: ...urely 6 Reconnect the two black wires to the new On Off Switch 7 Reinstall Pressure Control Board and screws with warning label facing out Power Supply Cord Replacement 110V WARNING Before proceeding follow the Pressure Relief Procedure outlined on Page 5 Additionally follow all other warnings to reduce the risk of an injection injury injury from moving parts or electric shock Always unplug the sp...

Page 22: ...0 246 Bypass housing includes items 216 and 217 1 219 700 721 O Ring 1 700 897 O Ring PTFE optional 220 700 250 Bypass valve stem 1 222 700 244 Spring 1 224 700 248 Bypass valve retainer 1 225 700 252 Bypass cam base 1 226 700 759 Dowel pin 1 227 700 697 Bypass valve handle 1 230 700 258 Bypass valve assembly 1 232 700 881 Gasket 1 233 761 057 O Ring 1 240 702 305 Filter housing assembly excludes ...

Page 23: ...ocedure outlined on page 5 Additionally follow all other warnings to reduce the risk of an injection injury injury from moving parts or electric shock Always unplug the sprayer before servicing 1 Remove the Pin 226 from Bypass Valve Handle 227 Push out Pin as shown in Figure 8 2 Remove Handle 227 and Bypass Cam 225 3 Using a wrench loosen Bypass Housing 218 and unscrew Inspect O Rings 216 217 4 Un...

Page 24: ...nd 700 793 Piston Guide Tool Also Included 391 700 804 Gasket 1 350 730 540 Fluid Section Complete low rider and skid includes 301 305 307 323 1 765 143 Fluid Section Complete high rider 1 For high rider only 755 109 Pail hook 1 702 239 Bypass hose assembly 1 710 033 Bolt 2 730 334 Hose clamp 1 765 142 Safety plate 1 300 302 304 306 305 307 301 308 309 310 311 313 314 312 318 319 320 321 322 317 3...

Page 25: ...ged Use fine sandpaper to remove dried paint 12 Reattach assemblies 309 312 to piston 308 and secure tightly with a wrench Packing Replacement 13 Unscrew hose 19 from fitting 392 14 Remove screws 306 with a 3 8 hex wrench and slide pump section down so that the piston is clear to slide off 15 Inspect polyethylene seal 391 on fitting after removing pump section Clean or Replace 16 Remove Retainer 3...

Page 26: ...43 702 060 Low Rider Frame 1 High Rider Frame Assembly Item Part Description Quantity 1 702 121 Handle 1 2 710 020 Hinge Lock 2 3 702 141 Main Frame includes items 8 and 9 1 4 710 194 Snap Ring 2 5 710 044 10 Wheel 2 6 710 058 Axle Washer 2 7 700 652 Bolt 4 8 710 199 Leg Plug 2 9 710 198 Brace Plug 2 10 702 125 High Rider Frame Complete 1 700 761 Cord Holder not shown 1 700 069 Screw not shown 2 1...

Page 27: ...f Coating Date Begun Site Gallons Sprayed Tips Used Date Completed Quantity Sizes Job Name Foreman s Name Type of Coating Date Begun Site Gallons Sprayed Tips Used Date Completed Quantity Sizes Job Name Foreman s Name Type of Coating Date Begun Site Gallons Sprayed Tips Used Date Completed Quantity Sizes Job Name Foreman s Name Type of Coating Date Begun Site Gallons Sprayed Tips Used Date Complet...

Page 28: ...an component parts or tampering with the unit in a manner to impair normal operation Defective parts are to be returned to an authorized Titan sales service outlet All transportation charges including return to the factory if necessary are to be borne and prepaid by the End User Repaired or replaced equipment will be returned to the End User transportation prepaid THERE IS NO OTHER EXPRESS WARRANT...