12
16) Remove the fill cap from the power unit and fill the oil tank reservoir. To fill the oil tank
reservoir, the lift must be completely lowered. Fill the oil tank with a premium quality
ISO-32, or AW-46 Hydraulic Oil.
17) Using the cable provided connect the ceiling safety switch to power unit. Be sure that
the cable should connect to the two normal closed terminals of the switch. (Fig.11)
18) Make the Electrical hookup to the power unit: 220V Single phase. It is recommended
that a 220 Volt, 30 Amp twist lock plug be installed in the power line just ahead of the
power unit. Use wire capable of supporting a 30-amp circuit. (Fig. 12 and diagram Fig.
5)
19) Lubricate the cables, sheaves, release latch and inner
corners in the columns (Fig.13). Install the single hand
releasing latch covers (23).
20) Check again for the plumb of the columns. The
distance at the bottom and at the top position between
the columns should be equal. Check the height of the
lifting arms. The difference should be within
1”.
21)
Do not place any vehicle on the lift at this time. Read
the operation instructions (pg 14-16) and cycle the lift
up and down several times to ensure safety latches
click together and all air is removed from the system. Ensure all hydraulic fittings are
tight and not leaking. To lower the lift, the safety latch releases must be manually
released. Latches will automatically reset once the lift ascends approximately 17” from
base.
NOTE:
If latches click out of sync, tighten the cable on the one that clicks first.
WARNING: THE WIRING MUST COMPLY WITH LOCAL CODE. HAVE A
CERTIFIED LICENSED ELECTRICIAN MAKE THE ELECTRICAL HOOK-UP TO THE
POWER UNIT. PROTECT EACH CIRCUIT WITH TIME
DELAY FUSE OR CIRCUIT BREAKER; 208V-230V
SINGLE PHASE. 50HZ/60HZ 30 AMP.
Fig. 13
lubricate the
cable and
latch
lubricate the
sheaves
lubricate the
inner corners
lubricate the
sheaves and
cables
WARNING: DO NOT PERFORM ANY MAINTENANCE OR INSTALLATION
OF ANY COMPONENTS WITHOUT FIRST ENSURING THAT ELECTRICAL POWER
HAS BEEN DISCONNECTED AT THE SOURCE OR PANEL AND CANNOT BE
REENERGIZED UNTIL ALL MAINTENANCE AND/OR INSTALLATION PROCEDURES
ARE COMPLETED.
DANGER: DO NOT RUN POWER UNIT WITHOUT FLUID. DAMAGE TO PUMP
CAN OCCUR. THE POWER UNIT MUST BE KEPT DRY. DAMAGE TO POWER UNIT
CAUSED BY WATER OR OTHER LIQUIDS SUCH AS DETERGENTS, ACID ETC., IS
NOT COVERED UNDER WARRANTY.