Orion 1 – 220 Volt Power Supply Overview
The Orion 1 220 Volt Power Supply uses the principle that 220/240 volts AC is supplied to most
facilities. The 220/240 volts is divided into 110/120 volt circuits for distribution within the build-
ing. Using 110/120 volt outlets and the Orion 1 Power Supply, the user can quickly identify and
connect to the separated 110/120 volt halves of the original 220/240, restoring the 220/240 volt
AC option without adding new electrical circuits or wiring to the building.
To protect people and equipment, the Orion 1 Power Supply’s safety interlock blocks all output
power until electrical connections are complete and correct. The Orion 1’s internal circuits
assure correct outlet polarity before completing electrical connections. Should power on one
of the 110/120 volt supply lines be interrupted by overload or disconnect, all output power is
immediately and automatically disconnected.
Definitions of Power Circuit:
1. “110/120 VAC” means an alternating current electrical source from 108 to 125 volts AC
supplied by a three pronged grounded outlet of the type commonly found in residential and
commercial applications in the United States. The source can be either single phase or three
phase, which is commonly found in commercial or industrial facilities.
2. “220/240 VAC” means 208 to 250 volts AC. If the power source is single phase, the voltage
output of the Orion 1 will be twice the voltage of the voltage supplied, typically 220 to 240
volts. If the power source is 3 phase, the voltage output will be 1.73 times the voltage of the
voltage supplied, typically 208 volts.
3. 220/240 volt power is supplied though NEMA 6-15R straight blade duplex outlet.
NEMA 6-15R
15 Amp, 220 to 240 Volts Nominal
Instructions for Operation
Use appropriate extension cords, as necessary, to reach 110/120 volt outlets, #16/3 or larger
extension cords are recommended. The Orion 1’s power supply will trip Ground Fault Interrupter
(GFI) circuits or outlets. Select non-GFI outlets and circuits. If a GFI is desired, use a 220/240
volt GFI, connecting it to the 220/240 volt output of the Orion 1 power supply.
1. 110/120 Volt Connections:
a. Test 110/120 volt outlets using supplied Receptacle Tester.
• Two amber “CORRECT” lights should be on. If lights give different reading, outlet is
not wired correctly and Orion 1will not operate. Have wiring corrected by a certified
Electrician.
• Press GFI test button on Receptacle Tester for 6 seconds. When released, the two
amber “Correct” lights should remain on. If amber lights go off, reset GFI in circuit
and move to outlet that is not GFI protected.
b. Connect “PLUG A” power cord to 110/120 volts AC outlet. The Orion 1 power
supply will give an audible “click” as “PLUG A” is inserted into the outlet. If there is
no “click,” disconnect and see Trouble Shooting, paragraph 4.
c. Connect “PLUG B” power cord to other 110/120 volt AC outlets until “220 Volts”
lamp on front panel illuminates. (An extension cord will probably be necessary.) As
“PLUG B” is inserted into the outlet, the Orion 1 power supply will give an audible
“click.” If there is no “click,” disconnect and see Trouble Shooting, paragraph 4.
• When “220 Volts” illuminates, 220 VAC is ready for use on the “220 volt power
output.”
• If “220 Volts” does not illuminate, move “Plug B” to other outlets until “220 Volts” lights.
Warranty Information
• Titan Controls
®
warrants the original purchase of this product against defects in material and
workmanship under normal use for three (3) years from the date of purchase.
• During the warranty period, Titan Controls
®
will, at our option, and without charge, repair or
replace this product if the controller or any of its components fail or malfunction.
• All returns or repairs must be accompanied by a Return Merchandise Authorization (RMA) num-
ber prior to any service of the product.
• This warranty is expressly in lieu of all other warranties, expressed or implied, including the war-
ranties of merchantability and fitness for use and of all other obligations or liabilities on the part of
the seller.
• This warranty shall not apply to this product or any part thereof which had been damaged by
accident, abuse, misuse, modification, negligence, alteration or misapplication.
• Controllers with serial numbers or date tags that have been removed, altered or obliterated;
broken seals or that show evidence of tampering; mismatched board serial numbers or noncon-
forming parts; are excluded from coverage.
• Titan Controls
®
makes no warranty whatsoever in respect to accessories or parts not supplied
by Titan Controls
®
.
• Monetary refunds of the warranty will not be given.
• The Buyer assumes all responsibility regarding the use & installation of this controller.
• All warranty service is provided through the factory or an authorized service representative.
• This warranty shall apply only to the United Sates, including Alaska, Hawaii and territories of the
United States.
• Defective controllers need to be returned with the “proof of purchase” receipt.
• For additional warranty information, contact a Titan Controls
®
Technical Service Representative
or your Dealer.
• NOTE: Titan Controls
®
is a controller manufacturer. All sales offerings to the public are
done through a nationwide group of Dealers. No sales offerings will be made directly to the
general public.
Service and Repair Program
• For all service and repairs please contact one of our Technical Service Representatives for a
Return Merchandise Authorization (RMA) number.
• All factory service & repairs will be completed within 48 hours of receipt of controller and after
authorization by customer for repairs.
• Titan Controls
®
will, at its discretion, repair or replace the controller.
• Factory calibration services are available for all Titan Controls
®
.