background image

Instructions for Use

1.  Please consult with a licensed electrician prior to installa-

tion of the Helios 3.  High voltage can be dangerous!

2.  Connect 240 volt power to the 3 screws under the pro-

tective cover.  (See ‘Instructions for Operation’ section).

3. Replace protective cover with screws provided.
4.  Securely mount your Helios 3, with hardware provided, 

near the ballasts to be operated. It should be placed 
away from water, mist, spray, etc.

5.  Plug your ballasts into the outlets on the left and right 

side of the controller.

6.  Set the time to current time of day.
7.  Turn on Helios 3 power switch to activate lighting 

controller.

8.  Your Helios 3 will now control your ballasts at the 

desired settings until the power is defeated.

Controller Specifi cations

Helios 3 

TM

4 Light - 240 volt Lighting Controller

Easy Guide

VANCOUVER, W ASHINGTON U.S.A.

®

Size: 11”H x 11”W x 4”D

Weight: 4 lbs.

Voltage Input: 240 volts

Voltage Output: 240 volts

Maximum Amperage: 30 amps

Maximum Wattage: 4000 Watts

Hertz: 60 Hz

Time switch: 24 Hours with 15 minute increments 

Operating Temperature: 40o to 125o F | 5o to 52o C

Storage Temperature: 32o to 135o F | 0o to 57o C

to 30 Amp Power Source

Fan

to 240 Volt Ballast

to 240 Volt Ballast

Sun System 

R

Sun System 

R

to 240 Volt Ballast

to 120 Volt 

Timed Outlet

to 240 Volt Ballast

Helios 3

240 Volt

Sun System 

R

Sun System 

R

Wiring 

diagram

Hot

Ne

u

tra

l

Gro

und

Hot

®

Controlling a light bank 

www.titancontrols.net

For technical assistance call us at 

1-888-80-Titan or 1-888-808-4826.