background image

The Venera Switch is a wall-mounted touch switch 

with multiple management options. It can be set 

up in three easy steps: remove your old switch 

and install the new one, connect it to the Internet, 

and start controlling it. Regardless of whether 

your residence is an apartment or a house with a 

big yard, once you replace the old switches, the 

Venera Switch is ready to go.

PRODUCT INFORMATION

VENERA TOUCH PANEL 

TIS VENERA 1-3 GANG PANEL

INSTALLATION MANUAL

Model: VEN-3S-3R-HC, VEN-2S-2R-HC, VEN-1S-1R-HC

PRODUCT SPECIFICATIONS

Power Supply

Input Voltage

110-230 VAC 50/60 Hz

Output Power 

3W / 12V

Protection

Built in Protection fuse

Current consumption

10-30 mA / 12 V DC

Output

Number of channels

2 / 3 (refer to Model number) 

Nominal voltage

110 / 230 V AC 50/60 Hz

Nominal current per channel

8 A / 230 VAC

Output switching current

Max switching current 

10A/230 VAC Resistive 

6A/230 VAC florescent 

Output service life

8A/230 VAC

Output switching times

277VAC / 30VDC

Output service life

Mechanical Endurance

> 10,000,000 OPS

Output switching times

Operating time

8mS (at nomi. Volt)

Releasing time 

5 mS  (at nomi. Volt)

Max. operating frequency 

25 cycle/min 

TIS AIR

WIFI Signal 

2.4 GHz

Protocol Standard

802.11 b/g/n

Operating and display 

elements

touch buttons

4 touch Capacitive buttons for control …

Infrared Receiver

Control it by TIS Remote control

Backlight  

RGB Backlight indicators 

TIS AIR  

TIS Protocol messages and commands

Upgrading

By WIFI Connection

Dimensions

Length × Width × Height

85mm × 42mm × 109mm

Housing

Materials 

PC fire-proof/ Glass in front

Internal Parts color

Black or White

IP rating

IP 50

Summary of Contents for VENERA VEN-1S-1R-HC

Page 1: ... 3 refer to Model number Nominal voltage 110 230 V AC 50 60 Hz Nominal current per channel 8 A 230 VAC Output switching current Max switching current 10A 230 VAC Resistive 6A 230 VAC florescent Output service life 8A 230 VAC Output switching times 277VAC 30VDC Output service life Mechanical Endurance 10 000 000 OPS Output switching times Operating time 8mS at nomi Volt Releasing time 5 mS at nomi ...

Page 2: ...ne Neutral and Load cables The installer should consider the total current consumption when selecting the wires Warranty There is a two year warranty provided by law The hologram warranty seal and product serial number are available on each device Read Instructions We recommend that you read this Instruction Manual before installation Safety instructions Electrical equipment should only be install...

Page 3: ...s company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL INSTALLATION STEPS 2 Remove the switch cover Unscrew and pull the wall switch out Take the wires out of the load and line 3 There should be a total of 3 5 wires 3 wires if 1 gang 4 wires if 2 gangs 5 wires if 3 gangs Find the ne...

Page 4: ...other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL INSTALLATION STEPS 4 Turn on the power at the main power breaker and carefully identify the live wire using a voltage tester 5 Turn off the power at the main power breaker again to turn off the voltage supply to the switch 6 Attach the neutral wire to the N termi...

Page 5: ...ark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL INSTALLATION STEPS 7 Insert the Venera panel and the wires in the box and secure the panel using 2 screws 8 9 Install the Venera panel s top cover as shown i...

Page 6: ...l of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL SERVER LINKING In order for a project to be fully linked to the TIS server server configuration must be enabled in just 1 product within that project If you have already done that with any other panel just ignore these steps and proceed to configuration steps To do the server link...

Page 7: ...S Logo is a Registered Trademark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL SERVER LINKING 4 Select your server option and 4 digit password Then press Save 3 On the TIS app press Search and wait for a few...

Page 8: ...C in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL 2 1 1 In the TIS App go to the settings and select TIS Air config and enter your SSID password 2 On the Venera panel press and hold the TIS logo for 6 seconds The logo will start blinking 6 C...

Page 9: ... 2020 TIS All Rights Reserved TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL 2 2 1 1 4 Select the room and then select channel names and icons 5 Go to the configured room s ...

Page 10: ...IS VENERA 1 3 GANG PANEL PAIRING MANUAL PROGRAMMING OTHER DEVICES THAT CAN CONTROL VENERA RELAYS 2 Go to any other wall panel and short press on any lighting button 3 Test by pressing on the wall panel s ON OFF button The Venera relay should respond by turning ON and OFF accordingly To pair the TIS Venera AIR Switch with any TIS wall panel buttons do the following CHANDELIER 00 00 00 IN 22 SPOTLIG...

Page 11: ... notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL PAIRING MANUAL PROGRAMMING VENERA BUTTONS TO CONTROL OTHER DEVICES 2 Shortly press on any Venera switch button 3 Test the button on the panel by short pressing it for ON OFF and long pressing to dim Venera buttons can be programmed to control any other relay dimmer or plug in the same TIS network You can pair any light channels with...

Page 12: ...RG button blinks purple color rapidly Reason The panel address conflicts with another device in the TIS network You need to press and hold the PRG button for 6 seconds so that the module can get a new address Device s PRG LED is RED Reason The device is not connected to Wi Fi Device can t link to Wi Fi router Reason 1 The device is too far from the Wi Fi router Reason 2 The SSID or password is not...