TIS RF-BELL-3S-OUT-LUNA Installation Manual Download Page 5

5

INSTALLATION MANUAL

Models: LUNA-OUT-3S-BELL, LUNA-OUT-3S-BELL-RF

TIS CONTROL LIMITED

RM 1502-p9 Easey CommBldg

253-261 Hennessy Rd Wanchai

Hong Kong

TEXAS INTELLIGENT SYSTEM LLC

SUITE# 610. 860 NORTH DOROTHY DR 

RICHARDSON

TX 75081.USA

Copyright © 2020 TIS, All Rights Reserved

TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the 

United States of America. This company takes TIS Control Ltd. in other 

countries. All of the Specifications are subject to change without notice.

w w w . t i s c o n t r o l . c o m

LUNA HOTEL OUTDOOR BELL & SERVICE PANEL

INSTALLATION STEPS  

6

7

Connect the Door Bell to the Relay if it 

exists  in  the  room.

If you want to connect electrical lock to 

the RF Hotel panel type please connect it 

as per this diagram.

LU

N

A OUTDO

O

R P

ANEL

Model: 

LUN
A -B
ELL-
3S

ww
w

.tis

smar

thome.

co

m

R7

R8

C2

VD4

L1

089

E3

Q4

C20 C26

DND CLEAN LUNDARY CARD GND

RIN

ROUT

R1

C1

E1

R3

VD6

E2

F3

D3

N1

+24V

D+

D-

GND

C4

Q

1

VD1

F1

F2

R2

ac

ac

RE

MO
VE

 A

FTER 

W

ASHING

HF04

227A

ac

GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)

Cat5e connection

+24V(brown-orange)

D+(blue-green)

1.5 mm Electric Cable

1.5 mm Electric Cable

low voltage cable

low voltage cable

Door Bell

Connect To L

Connect To N

Cat5e

to the TIS BUS Network

LUNA-BELL-3S-RF

AC/DC ADAPTER

Input 110~220V AC

Output  12V DC

LU

N

A OUTDO

O

R P

ANEL

Model: 

LUN

-B

ELL-
3S

ww
w

.tis

smar

thome.

co

m

R7

R8

C2

VD4

L1

089

E3

Q4

C20 C26

DND CLEAN LUNDARY CARD GND

RIN

ROUT

R1

C1

E1

R3

VD6

E2

F3

D3

N1

+24V

D+

D-

GND

C4

Q

1

VD1

F1

F2

R2

ac

ac

RE

MO
VE

 A

FTER 

W

ASHING

HF04

227A

ac

GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)

Cat5e connection

+24V(brown-orange)

D+(blue-green)

1.5 mm Electric Cable

1.5 mm Electric Cable

low voltage cable

low voltage cable

Electric Lock

Connect To L

Connect To N

Cat5e

to the TIS BUS Network

LUNA-BELL-3S-RF

AC/DC ADAPTER

Input 110~220V AC

Output  12V DC

Summary of Contents for RF-BELL-3S-OUT-LUNA

Page 1: ...nel Addition 4 Digital Inputs IF used the RF type RF Reader optional Frequency Output Low current relay 3 Relay Output 3A 5A TIS Bus Number of devices on 1 line Max 64 Bus voltage 12 32 V DC Current c...

Page 2: ...ith four twisted pairs Configure devices in a Daisy Chain Do not cut or terminate live data cables Warranty There is a two year warranty provided by law The hologram warranty seal and product serial n...

Page 3: ...d TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to chan...

Page 4: ...BUS wire to the Panel Addition Connect the other connection if needed between wall services switches to the digital inputs of the hotel panel as per the following diagram R7 R8 C2 VD4 L1 089 E3 Q4 C20...

Page 5: ...C2 VD4 L1 089 E3 Q4 C20 C26 DND CLEAN LUNDARY CARD GND RIN ROUT R1 C1 E1 R3 VD6 E2 F3 D3 N1 24V D D GND C4 Q1 VD1 F1 F2 R2 ac ac REMOVE AFTER WASHING HF04 227A ac GND white orange white brown D white...

Page 6: ...igent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m LU...

Page 7: ...OOR BELL SERVICE PANEL USER MANUAL The hotel service light will light up to a indicate service request such as Laundry Make Up Room or Do Not Disturb DND The backlit color can be set from the software...

Page 8: ...ontrol Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m LUNA HOTEL OUTDOOR BELL SERVICE PANEL TROUBLESHOOTING The panel buttons LED...

Reviews: