The Luna TFT panel has 3 page of layouts, each of 

which covers 6 commands (18 switches total) for 

limitless light control. It includes 2 pages for RGB 

color control, can control up to 8 air conditioning 

units, 2 floor heating units, music, curtains, moods, 

and security control. It can also monitor the energy 

meter, air quality, and weather station.  

Automation Made Easy

Model: LUNA-TFT43

PRODUCT INFORMATION

6

58921

79718

1

BARCODE (UPC-A)

PRODUCT SPECIFICATIONS

LCD

Size

3.5”

Resolution 

320*480 Pixels

Contrast 

500

Viewing angle

160 degree

Touch

Active area

4.3”

Touch Type

Capacitive 

Input

Temp sensor

Resistive Temp Sensor

IR receiver

TIS Infrared code receiver 

Using Panel Addition

2-3 Digital Input

Output

Using Panel Addition 3R

3 Relay Output 3A/5A

Using Panel Addition 3DL-12V  

12V DC 50mA Output

Using Panel Addition 2DL-IRE

IR Emitter 

TIS Bus

Number of devices on 1 line

Max. 64

Bus voltage

12-32 V DC

Current consumption

<50 mA / 24 V DC

Operating and display 

elements

LCD

TFT full color 

touch buttons

5 touch buttons for menu selection …

Backlight  

2 White indicators 

TIS bus 

TIS Protocol messages and commands

Upgrading

By Rs485 upgrading kit.

Functions

1 Press

ON/OFF/Scene

Long Press

Dim or ramp the lights

Double click 

Extra Scene 

IR receiver 

Music, scene, lights control 

Dimensions

Width × length × height

90mm (94mm peak) × 13mm × 129mm

Housing

Materials 

PC anti fire / Glass in front

Casing color

Silver plating frame. Glass white or black

Internal Parts color

Black  &  White

IP rating

IP 50

Summary of Contents for LUNA TFT43

Page 1: ...R receiver TIS Infrared code receiver Using Panel Addition 2 3 Digital Input Output Using Panel Addition 3R 3 Relay Output 3A 5A Using Panel Addition 3DL 12V 12V DC 50mA Output Using Panel Addition 2DL IRE IR Emitter TIS Bus Number of devices on 1 line Max 64 Bus voltage 12 32 V DC Current consumption 50 mA 24 V DC Operating and display elements LCD TFT full color touch buttons 5 touch buttons for...

Page 2: ... 3R type The installer should consider the total current consumption when selecting the wires Warranty There is a two year warranty provided by law The hologram warranty seal and product serial number are available on each device Read Instructions We recommend that you read this Instruction Manual before installation Safety instructions Electrical equipment should only be installed and fitted by e...

Page 3: ...go is a Registered Trademark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 3 Insert a large flathead screwdriver in the hole of the Panel Cover Rotate the screwdriver 90 degrees 1 INSTALLATION STEPS 2 Separat...

Page 4: ...f Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 4 Remove the 2 screws on the Panel Addition cover 3 INSTALLATION STEPS 4 Smart Home Smart Home Connect the Wall Base and Panel Addition in this position Place the ...

Page 5: ...ecifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 5 It should look like this following the correct assembly INSTALLATION STEPS 5 6 Turn off the main electrical source before installation WARNING HIGH VOLTAGE LOGO Connect the Cat5e TIS BUS wire to the Panel Addition PANEL ADDITION TIS BUS Input 75 45mA 24V DC Output Current 3A220VAC COM OUT3 ...

Page 6: ...ITION 2 Digital Input with IR Receiver Model ADD 2DL IRR TIS BUS Input 45mA 24V DC VCC REC GND Z2 Z1 www tissmarthome com D 24V GND D Luna TFT LCD Panel black TIS IR Receiver probe To the TIS BUS Network Cat5e INSTALLATION STEPS 7 Connect the other connection if needed as per the panel addition type FOR PANEL ADDITION 2DL IRR You can connect 2 digital inputs to any switch or window magnet Youcanad...

Page 7: ...reen low voltage cable low voltage cable PANEL ADDITION 2 Digital Input with IR Emitter Model ADD 2DL IRE TIS BUS Input 45mA 24V DC IR IR GND Z2 Z1 www tissmarthome com D 24V GND D Luna TFT LCD Panel black TIS IR Emitter probe To the TIS BUS Network Cat5e GND white orange white brown D white green white blue D blue green 24V brown orange Cat5e connection low voltage cable low voltage cable PANEL A...

Page 8: ...L 12V TIS BUS Input 45mA 24V DC 12V GND Z3 Z2 Z1 www tissmarthome com Output DC 12V 50mA D 24V GND D Luna TFT LCD Panel black C5 C2 PULSE 1 2 2 3 NONE 1P 2P 3P RELAY 1 2 2 3 NO NC 1 2 3 RELAY 1 2 2 3 NO NC 1 2 3 TAMPER ALARM 12V GND CON1 1 2 3 LED1 818 6B V2 3 2016 11 09 To the TIS BUS Network Cat5e GND white orange white brown D white green white blue D blue green 24V brown orange Cat5e connectio...

Page 9: ... GND D Connect To L Luna TFT LCD Panel black O OFF I ON MCB Open Close 220 110 Volt Connect To N To the TIS BUS Network Cat5e GND white orange white brown D white green white blue D blue green 24V brown orange Cat5e connection 1 5 mm Electric Cable 1 5 mm Electric Cable 2 5 mm Electric Cable PANEL ADDITION 3 Output Relay 5 Amp Model ADD 3R 5A TIS BUS Input 45 75mA 24V DC Output Current 3A220VAC CO...

Page 10: ...ent 3A220VAC COM OUT3 OUT2 OUT1 COM www tissmarthome com D 24V GND D To the TIS BUS Network Cat5e GND white orange white brown D white green white blue D blue green 24 V brown orange Cat5e connection 1 5 mm Electric Cable 1 5 mm Electric Cable 2 5 mm Electric Cable PANEL ADDITION 3 Output Relay 5 Amp Model ADD3 R5 A TIS BUS Input 75 45mA 24V DC Output Current 3A220VAC COM OUT3 OUT2 OUT1 COM www ti...

Page 11: ...trol Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 11 1 5 mm Electric Cable 1 5 mm Electric Cable O OFF I ON MCB Connect To L Connect To N TIS AIR BUS Convertor Model NO TIS AIR BUS 3W AC Input 100 240 V AC www tissmarthome com TIS AIR TIS BUS Output 100mA 12 V DC D 24V GND D N L INSTALLATION STEPS Mou...

Page 12: ...ntelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 12 INSTALLATION STEPS Connect the main Luna panel vertically to the part installed on the wall install the upper part by making sure the buckles are completely inside 10 Us...

Page 13: ...as Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 13 00 00 00 INDOOR 23 30 MINUTES ON OFF SPEED MODE 29 AC1 LOW HI MED AUT FAN HEAT COOL AUT INSTALLATION STEPS Push on the bottom part of the main panel to fix it to the...

Page 14: ...MMING You can pair the light channels with any wall panel To do so follow these steps RCU80 UT8 IN WARNING HIGH VOLTAGE TIS BUS GND D D 24 V PRG 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 8 7 GND 6 5 4 3 2 10 0V DIGITAL INPUT GND 1 1 Press any button on any relay or dimmer module channel for 6 seconds so that the LED indicator light of that button starts blinking 6 On the Luna lights pages shortly press on a...

Page 15: ... CEILING WALL LIGHT ROPE LIGHT FLUORESCENT OFF PIC ON PIC Change Light Pic NEXT CHANDELIER 00 00 00 IN 22 SPOTLIGHT CEILING WALL LIGHT ROPE LIGHT FLUORESCENT To change the icon and comment of each light button you need to long press on the light s icon that you want to change for 12 seconds a new page will be displayed In the new page you can choose the icon for OFF status and the icon for ON stat...

Page 16: ...own oran Cat5e connection 1 L 2 M 3 H 4 L 5 M 6 H 7 L 8 M 1 L 2 M TIS BUS GND D D 24V PRG 9 H 10 L 11 M 12 H 3 H 4 L 5 M 7 L 8 M 10 L 11 M 6 H 9 H 12 H A B C D VLC 12CH 10A WARNING HIGH VOLTAGE To the TIS BUS Network Cat5e PAIRING MANUAL PROGRAMMING FCU PROGRAMMING 1 To program the FCU to any wall thermostat panel press and hold the first Channel L LOW button for 6 seconds The LED indicator of the...

Page 17: ...IS LUNA TFT TOUCH PANEL 17 PAIRING MANUAL PROGRAMMING FCU PROGRAMMING You can change AC1 and AC2 page settings such as C F temperature type and disable or enable fan speeds and AC moods by pressing on the AC menu icon second icon under the LCD for 5 seconds and then pressing on the AC1 or AC2 changing the settings and pressing Save 4 00 00 00 INDOOR 23 30 MINUTES ON OFF SPEED MODE 29 AC1 LOW HI ME...

Page 18: ... n t r o l c o m TIS LUNA TFT TOUCH PANEL 18 PAIRING MANUAL PROGRAMMING HVAC PROGRAMMING 1 Press the PRG button on the HVAC module for 6 seconds until the green LED turns on and is steady On the Luna AC page turn the AC ON 2 Test your air conditioning by changing the mood heat cool and fan speed from low to medium to high The HVAC module should respond accordingly 3 HVAC6 3 A T Low Med Cool Heat P...

Page 19: ...m TIS LUNA TFT TOUCH PANEL 19 PAIRING MANUAL PROGRAMMING You can change the AC1 and AC2 page settings such as C F temperature type and disable or enable fan speeds and AC moods by pressing on the AC menu icon second icon under the LCD for 5 seconds Then press on the AC1 or AC2 change the settings and press Save 4 You can show or hide AC pages by long pressing on the AC icon for 5 seconds Then a ne...

Page 20: ...A TFT TOUCH PANEL 20 PAIRING MANUAL PROGRAMMING FLOOR HEATING PROGRAMMING 1 Press any button on any relay or dimmer module channel for 6 seconds so that the LED indicator light of that button starts blinking On the Luna floor heater page turn the floor heating ON 2 00 00 00 FLOOR 29 30 MINUTES ON 32 OFF 00 00 00 FLOOR 29 30 MINUTES ON 33 OFF Test your floor heating by changing the temperature the ...

Page 21: ...ited States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 21 PAIRING MANUAL PROGRAMMING FLOOR HEATING PROGRAMMING You can show or hide AC pages by long pressing on the AC icon for 5 seconds Then a new page will appear and you can show hide the AC master slave p...

Page 22: ...pecifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 22 PAIRING MANUAL PROGRAMMING 1 Long press the PRG buttons on the Audio Matrix for 8 seconds The PRG LED indicator will start blinking AM 00 00 SD SD MP3 USB AUX 2 AUX 1 RADIO A V On the Luna music page press the play button on the radio or USB SD card source 2 00 00 00 AUX Wait a few second...

Page 23: ...hange without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 23 AM 00 00 SD SD MP3 USB AUX 2 AUX 1 RADIO A V Sound VOLUME MAX 100 PLAY MODE Update SD Update USB NEXT Subnet ID Device ID Audio Player Address 2 201 SD MP3 USB RADIO AUX 1 TV Page AUX 2 You can change the treble and bass maximum volume and play mode by pressing on the Audio menu icon 3rd icon under the LCD for 5 secon...

Page 24: ...MMING SCENARIO PROGRAMMING In the Extra pages the Mood1 Mood2 and APP pages can program the scenes of the panel You can go to these pages by pressing on the Extra menu icon 4th icon under the LCD and then selecting the mood1 mood2 or app icon from the menu on the LCD To program the mood please do the following 1 Set the lights brightness ON OFF and RGB color on lights pages 1 2 and 3 and RGB1 and ...

Page 25: ...PROGRAMMING SCENARIO PROGRAMMING 4 Go to the Mood page and long press for 12 seconds on the mood icon you want to program A new window will appear to show you the options you want to save in your mood You can select what page settings you want to include such as light pages 1 2 and 3 RGB AC floor heating and music You can set your mood just to control lights or AC or music or to control them all t...

Page 26: ... o n t r o l c o m TIS LUNA TFT TOUCH PANEL 26 OTHER SETTINGS CHANGING YOUR SECURITY PASSWORD You can change the default security page password 1234 and the default duress password 9999 to new passwords To change the passwords you need to complete the following steps 1 Go to the Security page Press on the Extra icon for 5 seconds until a new page appears 2 Short press on Change Password to change ...

Page 27: ...takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 27 OTHER SETTINGS 4 Type the old password Type the new password and then save 5 Enter Old Password Enter New Password CHANGING DISPLAY SETTINGS You can change the background color and other options by doing the following 1 Press and hold t...

Page 28: ...o m TIS LUNA TFT TOUCH PANEL 28 OTHER SETTINGS On this page you can change the panel skins background color and brightness level and enable the default page settings and lock page settings 2 Also you can press Clean screen to disable the touch function for 30 seconds so that you can clean the screen Set Brightness Background Color Device ID Other Default Page Clean Screen LUNA Version Set Brightne...

Page 29: ...CH PANEL 29 USER MANUAL USING THE PANEL MENU You can navigate between different pages using the Menu icons under the LCD LIGHTS CONTROL When you press the lights icon under the LCD the lights page will shift in the following sequence lights page 1 lights page 2 lights page 3 RGB page 1 RGB page 2 CHANDELIER 00 00 00 IN 22 SPOTLIGHT CEILING WALL LIGHT ROPE LIGHT FLUORESCENT CHANDELIER 00 00 00 IN 2...

Page 30: ...otice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 30 In each RGBW page you can control one RGBW color with 3 Favorite buttons In each RGB page you can select the color and then press the ON button to play it You can also save your favorite color by selecting your color first and then pressing and holding on FAV1 FAV2 or FAV3 for 6 seconds to save The FAV button color will change to th...

Page 31: ... modes You can also set a timer to turn the AC ON if it was OFF or to turn it OFF if it was ON by pressing on the timer and you can adjust the timer by pressing on the clock many times In the floor heating pages you can turn it ON OFF by pressing on the ON OFF button and you can change the set temperature AC CONTROL You can navigate between the AC control page AC1 AC8 Slave AC1 2 and floor heater ...

Page 32: ...e w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 32 00 00 00 00 00 00 00 USB USER MANUAL Press on the music icon then select your source such as SD card USB FM Radio Auxiliary or TV control In USB SD you can play your next or previous album and track and you can increase or decrease the volume In FM radio you can scan the channels by pressing and holding on the scan button for 3 seconds ...

Page 33: ... is a Registered Trademark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 33 In Auxiliary inputs you can play stop In TV control you can send infrared commands to control your TV by pressing on the related ico...

Page 34: ... w t i s c o n t r o l c o m TIS LUNA TFT TOUCH PANEL 34 00 00 00 MOODS1 MOODS2 APP MOTOR SCEURITY ZONE ENERGY WAETHER 00 00 00 VACATION AWAY DISARM PANIC BUTTON NIGHT SECURITY 00 00 00 VACATION AWAY DISARM PANIC BUTTON NIGHT SECURITY USER MANUAL Press the extra menu icon and select Security from the LCD menu Then you can arm your system for vacation away night or day mode or you can disarm it Onc...

Page 35: ...e Control to run programmed buttons 1 12 You can control the AC floor heater music audio player curtains security arming and disarming and moods MESSAGES DISPLAY The panel can display urgent messages with a buzzer sounding on its LCD For normal messages a message icon will appear in the top left corner of the LCD and you will need to press on it to display the message on the LCD screen 00 00 00 IN...

Page 36: ... 1 There is no TIS BUS power or no connection to the L N input if used AIR bus 3W converter Reason 2 The TIS 24V power supply is not connected to the TIS BUS The wall panels fail to pair with other devices Reason 1 The TIS BUS connection has a problem or the wire has a short Reason 2 The manual programming function is disabled on the device it is enabled by default The wall panels fail to control ...

Reviews: