8-GanG PuSh-buTTOn Panel
16
TROubleShOOTInG
The panel’s buttons
blinks rapidly
Reason:
The panel address conflicts with another
device in the TIS network. You need to press and hold
any push button for 6 seconds so that the panel can
get a new address.
The panel buttons’
LEDs do not turn ON,
and the device is not
powered
Reason 1:
There is no TIS-BUS power or no connec-
tion to the L/N input (if used AIR bus-3W converter).
Reason 2:
The TIS 24V power supply is not connect-
ed to the TIS-BUS.
The wall panels fail to
pair with other devices
Reason 1:
The TIS-BUS connection has a problem, or
the wire has a short.
Reason 2:
The manual programming function is dis-
abled on the device (it is enabled by default).
The wall panels fail
to control the device
channels
Reason 1:
The TIS-BUS connection has a problem, or
the wire has a short.
Reason 2:
The programming address is faulty.
The backlite display
on some buttons is the
wrong color if the light
is turned ON/OFF
Reason:
Software LED backlite setting has been
changed. Please program it to show the correct color.