W A R N I N G S  

• 

If this equipment is installed or used in a manner not specified by the manufacturer 
then the protection provided by the equipment may be impaired. 

• 

This equipment contains a lithium battery. Danger of explosion if the battery is 
incorrectly fitted. Do not cut open, incinerate, recharge or expose to temperatures in 
excess of 100°C (212°F). 

• 

The battery should be replaced by a trained technician using the battery supplied in 
the appropriate manufacturer’s service pack. 

• 

This equipment should only be interfaced to a UL or CSA listed computer with RS232 
levels of not more than ±12V. 

• 

This equipment should only be interfaced to equipment which is powered by a Safety 
Extra Low Voltage Supply. The maximum voltage levels are to be 30V rms, 42V peak 
or 60Vdc and separated from hazardous voltages by double or reinforced insulation. 
For the United States consider a Safety Extra Low Voltage Supply to be a Class 2 
source as defined in the National Electrical Code. If the unit is connected to a 
computer outdoors the computer must also comply. 

• 

This equipment should be used within the temperature range and other 
environmental conditions specified in this manual. 

 

Summary of Contents for Transit 2

Page 1: ...Tinytag Transit 2 Manual...

Page 2: ...2...

Page 3: ...3 C O N T EN T S Warnings 4 Getting Started 5 Features 6 LED Flash Patterns 9 Specification 10 Calibration 11 Battery Replacement 12 Approvals 13 Warranty 14 Disposal 14 Further Information 15...

Page 4: ...is equipment should only be interfaced to a UL or CSA listed computer with RS232 levels of not more than 12V This equipment should only be interfaced to equipment which is powered by a Safety Extra Lo...

Page 5: ...pad or cable as described in the Tinytag Explorer quick start guide To use the Tinytag Transit 2 with an inductive pad it is simply as case of positioning the logger in the centre of the pad as shown...

Page 6: ...Reading Types overleaf then the memory is split equally between the different reading types selected All of the following features are programmable and are set in the logger using the Tinytag Explore...

Page 7: ...l as well or any combination of the three Trigger Start The Tinytag Transit 2 has a trigger start option that allows a user to set up a data logger as they wish it to record and then start it remotely...

Page 8: ...et for is 45 days and if no delay start is selected the logger will start recording immediately Stop Options The logger can be configured to stop in one of three different ways when it s memory is ful...

Page 9: ...e goes back to acceptable values once again A logger with latched alarms will only flash its red LED whilst the logger is recording if the logger stops the red LED will stop as well L E D F L A S H P...

Page 10: ...Reading Accuracy 0 4 C between 0 and 50 C Reading Resolution 0 01 C or better Response Time 10 mins to 90 FSD in moving air IP Rating IP54 splash proof For more detailed information on the data logge...

Page 11: ...in this manual We recommend that the calibration of this unit should be checked annually against a calibrated reference meter A UKAS traceable certificate of calibration can be supplied if the unit is...

Page 12: ...e stopped When replacing the battery wait at least one minute after removing the old battery before fitting the new one Data stored on the logger will be retained after a battery is replaced If used a...

Page 13: ...his device may not cause any harmful interference and 2 the device must accept any interference received including interference that may cause undesired operation Gemini Data Loggers UK Ltd operates Q...

Page 14: ...e point of sale for disposal W AR RA N TY This product carries a manufacturing defects warranty of 12 months from the date of purchase Units returned under warranty will be repaired or replaced at the...

Page 15: ...formation on Tinytag data loggers software and accessories can be found on our web site at www tinytag info If you should have any further questions please contact your distributor or Gemini Technical...

Page 16: ...16 Gemini Data Loggers UK Ltd Scientific House Terminus Road Chichester West Sussex PO19 8UJ England www tinytag info t 44 0 1243 813000 e sales tinytag info 9800 0040 Issue 6 18th July 2014...

Reviews: